Five Star Sr200na, Sr200lp,, Sr333na, Sr333lp,, Sr400na, Sr400lp Diagnostic LED’s SFS, SFS on

Page 29

Diagnostic LED’s: SFS

SFS “on”

A)Is the Stack Flue Switch or Sensor correctly connected to the wiring harness?

B)Is the Membrane Pad connected to the correct pins on the Control Board?

(See Page 36)

YES

Check the J3 and J6 NO connectors for corrosion

on the male pins. Corrosion found?

YES

Clean pins

DONE

Reset power to Heater and retry. Heater should fire.

NO

Verify whether you have a Stack Flue Sensor or a Stack Flue Switch

(See Page 4-11 in S5066, “Sta-Rite Pool/Spa Heater Training and Service Manual”).

NO

NO

Reconnect correctly.

DONE

Reset power to Heater and retry. Heater should fire.

Replace Stack Flue Sensor.

YES

Does the Digital Temerature Display show Error Code “E05” or “E06”?

SENSOR

NO

Replace Heater Membrane Pad Assembly, reset power to Heater and retry. Heater should fire.

NO

Replace Heater Control Board with new style board, reset power to Heater and retry. Heater should fire.

NO

Change Low Level Board Programming to “SF1” (See Page 4-11 in S5066, “Sta-Rite Pool/Spa Heater Training and Service Manual”). Were you able to change the device code (SF0 to SF1)?

YES

Reset power to Heater and retry. Heater should fire.

NO

Check Heat Exchange Coil for liming or low flow.

SWITCH

Does the Digital Temerature Display show Error Code “E05” or “E06”?

NO

Reset power to Heater and retry. Heater should fire.

NO

Replace switch, reset power to Heater and retry.

YES

YES

Change Low Level Board Programming to “SF0” (See Page 4-11 in S5066, “Sta-Rite Pool/Spa Heater Training and Service Manual”). Were you able to change the device code (SF1 to SF0)?

Check Heat Exchanger Coil for liming or low flow.

YES

NO

Reset power to Heater and retry. Heater should fire.

YES

Did Error Code (E05 or E06) disappear after change?

NO

Replace Heater Control Board, reset power to Heater and retry. Heater should fire.

NO

Replace Heater Membrane Pad Assembly, reset power to Heater and retry. Heater should fire.

29

Image 29
Contents Sta-Rite Pool/Spa Group Special Instructions to OwnerTo Consumer To InstallerSafety Instructions OWNER’S Operating Instructions Description of the HeaterSequence of Operation START-UP and OperationOperating Instructions SPA Temperature CautionWhat to do if YOU Smell GAS Operating Control To Turn OFF GAS to the ApplianceAfter START-UP Maintenance Instructions Care and MaintenancePutting the Heater Into Service Installation InstructionsOutdoor Installation Instructions Heater Clearances OutdoorInstallation in a Garage Or Utility Room Indoor Installation InstructionsControl Panel Indexing Heater Clearances IndoorOutside Vent Cover Removal Indoor Vent InstallationCombustion and Ventilation AIR Supply Min. Height Vertical Venting Negative PressureMetal Flue Collar Sta-Rite Part No Roof Pitch Above Roof Connecting Special GAS Vent to the HeaterMinimum Height Brand Manufacturer Material Type Sealant MinSpecial Gas Vent Vertical or Horizontal No. of 90 Elbows Water ConnectionsCool Water Water PipingWater Chemistry Water Flow RateModel Minimum Flow Maximum Flow 200 120 333 400 Chemical ValuesPressure Relief Valve Water Pressure SwitchConnect Gas Valve to End Cap Air Orifice Supplying Power to the Heater Pressure TestingElectrical Wiring GAS ConnectionsFuse FIREMAN’S Switch ConnectionMax Temperature Set Point Controls Maximum Temperature SET PointHeater LED come Initial TroubleshootingDoes red Service Start Heater Will Not Fire aContinue Heater Will Not Fire BHeater Will Not Fire C Heater Will Not Fire D Do not jumper a safety switch to remedy a failed switch Diagnostic LED’s AGS, AFS, HLS, PS, ThermistorSFS on Diagnostic LED’s SFSHeat Exchanger Troubleshooting Burner TroubleshootingRepair Parts are available from your Sta-Rite dealer 2692 Repair Parts Burner System Repair Parts Water System Repair Parts Electrical System Pool Heater Wiring Connection Diagram Pool Heater Electrical Schematic Ladder Diagram Page Page Warranty Registration Card