Five Star Sr200na, Sr200lp,, Sr333na, Sr333lp,, Sr400na, Sr400lp Initial Troubleshooting

Page 23

Initial Troubleshooting

Only qualified, trained service technicians with appropriate test equipment should service the heater. Remember that all parts of the system affect heater operation. Before starting this troubleshooting procedure, make sure that the pump is running correctly, that there are no blockages in the system, that the valves are correctly set and that the time clock is correctly set and is running.

Start here for directions to specific Troubleshooting Chart

Is green “POOL” or “SPA” LED “on”?

YES

Is red “SERVICE SYSTEM” LED “on”?

NO

Is red “SERVICE HEATER” LED “on”?

NO

Turn off 120 VAC power to heater for about 5 seconds, and turn back on. Make sure temperature setting is above water temperature. Wait one minute.

NO

YES

 

YES

 

Are any red diagnos-

YES

 

 

tic LED’s on back of

 

 

 

board (AGS, AFS,

 

 

 

 

 

 

 

SFS, HLS, PS or

 

 

 

 

THERMISTOR) “on”

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

YES

Go to chart “HEATER WILL NOT FIRE - A”

(Page 24)

Go to chart “HEATER WILL NOT FIRE - B”

(Page 25)

Go to specific safety switch troubleshooting chart (Pages 28 and 29)

Do any diagnostic LED’s on back of board (AGS, AFS, SFS, HLS, PS, or THERMISTOR) come “on” and stay on?

NOTICE: Any or all of the diag- nostic LED’s may come “on” momentarily when you turn on the power to the heater.

NO

 

Does red “SERVICE

YES

 

 

HEATER” LED come

 

 

 

 

 

“on”

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

Verify that water temperature setting is above water temperature reading. If it is, and heater either will not fire or no red LED’s come “on”, replace Control Board.

Go to chart ‘HEATER WILL NOT FIRE -C”

(Page 26)

Hazardous voltage. Can shock, burn or kill. Disconnect power before servicing any components.

Fire and Explosion hazard. Do not jumper switch terminals to remedy a failed safety switch.

23

Image 23
Contents Sta-Rite Pool/Spa Group Special Instructions to OwnerTo Consumer To InstallerSafety Instructions START-UP and Operation Description of the HeaterOWNER’S Operating Instructions Sequence of OperationOperating Instructions SPA Temperature CautionWhat to do if YOU Smell GAS Operating Control To Turn OFF GAS to the ApplianceAfter START-UP Maintenance Instructions Care and MaintenanceHeater Clearances Outdoor Installation InstructionsPutting the Heater Into Service Outdoor Installation InstructionsHeater Clearances Indoor Indoor Installation InstructionsInstallation in a Garage Or Utility Room Control Panel IndexingOutside Vent Cover Removal Indoor Vent InstallationCombustion and Ventilation AIR Supply Min. Height Vertical Venting Negative PressureMetal Flue Collar Sta-Rite Part No Roof Pitch Above Roof Connecting Special GAS Vent to the HeaterMinimum Height Brand Manufacturer Material Type Sealant MinSpecial Gas Vent Vertical or Horizontal No. of 90 Elbows Water ConnectionsCool Water Water PipingChemical Values Water Flow RateWater Chemistry Model Minimum Flow Maximum Flow 200 120 333 400Pressure Relief Valve Water Pressure SwitchConnect Gas Valve to End Cap Air Orifice GAS Connections Pressure Testing Supplying Power to the Heater Electrical WiringFuse FIREMAN’S Switch ConnectionMax Temperature Set Point Controls Maximum Temperature SET PointHeater LED come Initial TroubleshootingDoes red Service Start Heater Will Not Fire aContinue Heater Will Not Fire BHeater Will Not Fire C Heater Will Not Fire D Do not jumper a safety switch to remedy a failed switch Diagnostic LED’s AGS, AFS, HLS, PS, ThermistorSFS on Diagnostic LED’s SFSHeat Exchanger Troubleshooting Burner TroubleshootingRepair Parts are available from your Sta-Rite dealer 2692 Repair Parts Burner System Repair Parts Water System Repair Parts Electrical System Pool Heater Wiring Connection Diagram Pool Heater Electrical Schematic Ladder Diagram Page Page Warranty Registration Card