Subaru Robin Power Products RGV4100 Measuring Procedures, Measuring Instruments, Specifications

Page 29

8. MEASURING PROCEDURES

8-1 MEASURING INSTRUMENTS

 

 

 

 

 

 

8-1-1 “Dr. ROBIN” GENERATOR TESTER

 

 

 

The “Dr. Robin” generator tester is exclusively

 

 

 

designed for fast, easy diagnosis and repair of

 

 

 

Robin generators. The “Dr. Robin” has the follow-

 

 

 

ing features :

 

 

 

(1) Functions of voltmeter, frequency meter,

 

 

 

megger tester, capacitance meter and circuit

 

 

 

tester are combined in one unit.

 

 

 

(2) Fast and easy readout by digital indicator.

 

 

 

(3) Built-in automatic battery checker indicates the

 

 

 

 

Fig. 8-1

 

time to change batteries.

 

 

 

(4) Tester and accessories are installed in a handy,

 

 

sturdy case for easy carrying.

 

 

* SPECIFICATIONS

 

 

 

 

 

MODEL

Dr. Robin

 

 

 

 

 

 

 

 

 

 

Part Number

388-47565-08

 

 

 

 

 

 

 

 

Voltage

0 to 500 V AC

 

 

 

 

 

 

 

 

Frequency

25 to 70 Hz

 

 

Measuring

 

 

 

 

Resistance

0.1 to 1.999 Ω

 

 

Range

 

 

 

 

 

 

 

Condenser Capacity

10 to 100 μF

 

 

 

 

 

 

 

 

Insulation Resistance

3MΩ

 

 

 

 

 

 

 

Circuit Protector

Fuse

 

 

 

 

 

 

 

Power Source

2 x 6F44P (006P) Dry Cell Battery

 

 

 

 

 

 

 

 

Accessories

Test leads with needle probes . . . 1 set

 

 

Test leads with jack plugs . . . 1 set

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions (L x W x H)

285 mm x 200 mm x 110 mm

 

 

 

 

 

 

 

Weight

1.6 kg

 

 

 

 

 

 

 

Table. 8-1

The “Dr. Robin” generator tester can be ordered from Robin generator distributors by the following part number.

Dr. Robin Part Number : 388-47565-08

If you do not have a “Dr. Robin” generator tester, use the instruments described in the following section for checking generator parts.

- 26 -

Image 29
Contents RGV2800, RGV4100, RGV6100 Generators Contents Troubleshooting Disassembly and AssemblyWiring Diagram Specifcations Generator Trouble ShootingEngine SpecificationsModel RGV2800 RGV4100EH34D RGV6100250 125 240 120 230 115 220 110 230V/115V Load Rated Perfomance CurvesDC Output Features LONG-LIFE Durability Minimal MaintenanceOIL Drain Plug General DescriptionExternal View RGV4100 U.S.A., 60Hz-120V/240V Nema Receptacle Control PanelRGV2800 U.S.A., 60Hz-120V Nema Receptacle RGV6100 U.S.A., 60Hz-120V/240V Nema Receptacle Location of Serial Number and Specification NumberConstruction Construction and FunctionFunction StatorRotor CondenserDC Circuit Breaker NO-FUSE BreakerObject or Protection RGV2800AC plug Description Style AmpereConnecting to Domestic Circuits House Wiring 240V appliance Voltage Fluctuations Under Load Generator OperationGeneration of NO-LOAD Voltage Switch Full Power Switch Dual Voltage TypePosition 120/240 Half of rated output Rated outputPage Description Power supplyPrinciple of Sensing OIL Level HOW IT OperatesJudgement of oil level Block Diagram of the CircuitDecision of oil shortage Automatic stop of enginePage Do not connect the generator to the commercial power lines Safety PrecautionsDo not place inflammable materials near the generator Operate the generator on a level surface Range of Applications Incandescent lamp, heater, etc. with a power factor Mercury lamps with a smaller power factor RGV2800 RGV4100 RGV6100 Appliances without any indication as to power consumption10 a 12 a 15 a Sectional Allowable Gauge No ResistanceArea / mm3 Current / a Specifications Measuring ProceduresMeasuring Instruments 1 Dr. Robin Generator TesterVoltmeter InstrumentsCircuit Tester Rated voltage 120 240 AC Output MeasuringDC Output Measuring Rotor Measuring Insulation ResistanceStator Control Panel AC Receptacles Checking Functional MembersVoltmeter Winding Specification AC Winding Condenser75 Ω 77 Ω 60 Ω Rotor AssemblyCondenser Checking table for analogue circuit tester Diode RectifierApply red plus needle Brown Circuit tester OrangeApply black minus needle Brown Checking table for digital circuit testerCircuit tester Brown / WhitePreparation and Precautions Disassembly and AssemblyStep Part to remove Description Remarks Tool Disassembly ProceduresRubber Pipe Hose Clamp Step Part to remove Description Remarks Tool M8 flange nut pcs Rear Cover Stator Cover Rear Cover Brushing Spring Seal Tape Part to remove Description Remarks Tool Front Cover Assembly ProceduresTightening torque 11.8 13.7 N-m Tightening torque 11.3 13.2 N-m RGV2800Tightening torque 5.9 N-m Rear CoverFrame END Cover RGV4100 onlyTightening torque 18.6 24.5 N-m Tightening torque 9.8 N-mTightening torque 21.6 27.4 N-m Tightening torque 6.9 N-m Checking of the Front Panel DisassemblyFront Panel Tightening torque 1.5 N-m ReassemblyNo AC Output TroubleshootingChecking Condenser Checking StatorRemedy Checking RotorAC Voltage is TOO High or TOO LOW How to adjust engine r.p.mChecking Engine Speed Checking RotorCheck the Appliance for Trouble Check the Engine SpeedCheck if the Engine is Overheated Check the Insulation of the GeneratorNo DC Output Check the DC Coil Engine Speed is not Increased When a Load is AppliedIdle Control Apply red plus needle Single Voltage TypeDual Voltage Type Normal Resistance Engine Speed is not Reduced When Load is OFFRGV4100 U.S.A., 60Hz-120V/240V Type Nema Receptacle Wiring DiagramRGV2800 U.S.A., 60Hz-120V Type Nema Receptacle Generator RGV6100 U.S.A., 50Hz-120V/240V Type Nema ReceptacleRGV4100, 6100 Electric Starter Type Wiring color cordOdelM RGV4101RGV6101RGV4101 Generator TroubleshootingRGV4101 RGV6101 85 Ω RGV4101 RGV6101 Check the Engine Speed No DC Output Checking table for analogue circuit tester Idle Control Optional Equipment Idelcontrolunit Output Wire ZCT TheIDELCONTROLUNIT Range of Applications Appliances without any indication as to power consumption Sectional Allowable Gauge No Resistance RGV4101 Electric starter model RGV4101RGV6101 Electric starter model RGV6101Lively Blvd. Wood Dale, IL 60191 Phone 630-350-8200 Fax