Subaru Robin Power Products RGV4100, RGV6100 service manual Checking Rotor, Remedy

Page 57

(3)Check the insulation resistance between sta- tor core and each stator lead using a Dr. Robin generator tester in megger tester mode or a megger tester. (Fig. 11-3)

If insulation is bad, replace stator with a new one.

Fig. 11-3

11-1-3 CHECKING ROTOR

(1) Remove rear cover and stator.

(2) Using a Dr. Robin or a circuit tester, measure

 

 

 

the resistance of the field coil at the terminals.

 

 

Fig. 11-4

 

 

 

 

 

( Ω)

 

 

 

 

 

 

 

MODEL

RGV2800

RGV4100

RGV6100

 

 

 

 

 

 

 

 

 

RESISTANCE

1.75 Ω

1.77 Ω

 

1.60 Ω

 

 

 

 

 

 

 

 

Table. 11-2

NOTE : Because a diode is soldered to the coil ends at the terminals, resistance may be mea- sured only when tester probes touch the termi- nals in one combination of polarity. Therefore, if no resistance reading appears, try checking in reverse polarity.

[Remedy]

If the resistance is not normal, replace rotor with a new one.

Fig. 11-5

- 54 -

Image 57
Contents Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page