(3)Measure the insulation across one of the sol- dered terminals of the rotor and the core. (Fig.11-6)

If insulation is bad, replace rotor with a new one.

11-2 AC VOLTAGE IS TOO HIGH OR TOO LOW

11-2-1 CHECKING ENGINE SPEED

If the engine speed is too high or too low, adjust it to the rated r.p.m.

[How to adjust engine r.p.m.]

*Loosen the lock nut on the adjusting screw.

*Turn the adjusting screw clockwise to decrease engine speed or counterclockwise to increase engine speed.

Normal engine speed at no load

3700 to 3750 rpm

11-2-2 CHECKING CONDENSER

Check condenser referring to Step 11-1-1.

11-2-3 CHECKING STATOR

Check stator referring to Step 11-1-2.

11-2-4 CHECKING ROTOR

Check rotor referring to Step 11-1-3.

Fig. 11-6

SPEED CONTROL LEVER

ADJUSTING SCREW

RGV2800,4100

RGV6100

Fig. 11-7

- 55 -

Image 58
Contents RGV2800, RGV4100, RGV6100 Generators Contents Wiring Diagram Disassembly and AssemblyTroubleshooting Specifcations Generator Trouble ShootingModel SpecificationsEngine RGV2800 RGV4100RGV6100 EH34DPerfomance Curves 250 125 240 120 230 115 220 110 230V/115V Load RatedDC Output Features Minimal Maintenance LONG-LIFE DurabilityExternal View General DescriptionOIL Drain Plug RGV2800 U.S.A., 60Hz-120V Nema Receptacle Control PanelRGV4100 U.S.A., 60Hz-120V/240V Nema Receptacle Location of Serial Number and Specification Number RGV6100 U.S.A., 60Hz-120V/240V Nema ReceptacleFunction Construction and FunctionConstruction StatorCondenser RotorObject or Protection NO-FUSE BreakerDC Circuit Breaker RGV2800Style Ampere AC plug DescriptionConnecting to Domestic Circuits House Wiring 240V appliance Generation of NO-LOAD Voltage Generator OperationVoltage Fluctuations Under Load Position Full Power Switch Dual Voltage TypeSwitch 120/240 Half of rated output Rated outputPage Principle of Sensing OIL Level Power supplyDescription HOW IT OperatesDecision of oil shortage Block Diagram of the CircuitJudgement of oil level Automatic stop of enginePage Do not place inflammable materials near the generator Safety PrecautionsDo not connect the generator to the commercial power lines Operate the generator on a level surfaceMercury lamps with a smaller power factor Incandescent lamp, heater, etc. with a power factorRange of Applications Appliances without any indication as to power consumption RGV2800 RGV4100 RGV6100Area / mm3 Current / a Sectional Allowable Gauge No Resistance10 a 12 a 15 a Measuring Instruments Measuring ProceduresSpecifications 1 Dr. Robin Generator TesterInstruments VoltmeterCircuit Tester DC Output Measuring AC Output MeasuringRated voltage 120 240 Stator Measuring Insulation ResistanceRotor Control Panel Voltmeter Checking Functional MembersAC Receptacles Specification AC Winding Condenser WindingCondenser Rotor Assembly75 Ω 77 Ω 60 Ω Apply red plus needle Brown Diode RectifierChecking table for analogue circuit tester Circuit tester OrangeCircuit tester Checking table for digital circuit testerApply black minus needle Brown Brown / WhiteDisassembly and Assembly Preparation and PrecautionsDisassembly Procedures Step Part to remove Description Remarks ToolRubber Pipe Hose Clamp Step Part to remove Description Remarks Tool M8 flange nut pcs Rear Cover Stator Cover Rear Cover Brushing Spring Seal Tape Part to remove Description Remarks Tool Tightening torque 11.8 13.7 N-m Assembly ProceduresFront Cover Tightening torque 11.3 13.2 N-m RGV2800Rear Cover Tightening torque 5.9 N-mEND Cover RGV4100 only FrameTightening torque 21.6 27.4 N-m Tightening torque 9.8 N-mTightening torque 18.6 24.5 N-m Tightening torque 6.9 N-m Front Panel DisassemblyChecking of the Front Panel Reassembly Tightening torque 1.5 N-mChecking Condenser TroubleshootingNo AC Output Checking StatorChecking Rotor RemedyChecking Engine Speed How to adjust engine r.p.mAC Voltage is TOO High or TOO LOW Checking RotorCheck if the Engine is Overheated Check the Engine SpeedCheck the Appliance for Trouble Check the Insulation of the GeneratorNo DC Output Idle Control Engine Speed is not Increased When a Load is AppliedCheck the DC Coil Dual Voltage Type Single Voltage TypeApply red plus needle Engine Speed is not Reduced When Load is OFF Normal ResistanceRGV2800 U.S.A., 60Hz-120V Type Nema Receptacle Wiring DiagramRGV4100 U.S.A., 60Hz-120V/240V Type Nema Receptacle RGV6100 U.S.A., 50Hz-120V/240V Type Nema Receptacle GeneratorWiring color cord RGV4100, 6100 Electric Starter TypeRGV4101RGV6101 OdelMRGV4101 RGV6101 Generator TroubleshootingRGV4101 85 Ω RGV4101 RGV6101 Check the Engine Speed No DC Output Checking table for analogue circuit tester Idle Control Optional Equipment Idelcontrolunit Output Wire ZCT TheIDELCONTROLUNIT Range of Applications Appliances without any indication as to power consumption Sectional Allowable Gauge No Resistance RGV4101 RGV4101 Electric starter modelRGV6101 RGV6101 Electric starter modelLively Blvd. Wood Dale, IL 60191 Phone 630-350-8200 Fax