Subaru Robin Power Products RGV12100 service manual AC Receptacle, RGV13100T, - 11-

Page 14

4-2-11 AC Receptacle

AC receptacles are used for taking AC output power from the generator.

A total of 4 kinds of receptacle, each varying in rated voltage and current from another, are used. As many AC plugs as the receptacles, each matching the corresponding receptacle, are provided.

The rated current for each receptacle is shown as follows;

CAUTION

Be careful not to use the receptacles beyond the specified amperage limits to prevent burning.

 

 

MAX 30A

MAX

30A

50A

MAX 20A

MAX

20A

 

MAX

 

 

 

 

AC120V

 

AC 120V / 240V

 

 

 

30A or less

 

50A or less

20A or less

 

30A or less

 

 

 

Total 50A or less

 

 

 

(RGV12100)

 

 

CAUTION

 

 

 

To connect the appliance to the locking type receptacle, insert the plug in to the receptacle and then turn it clockwise to lock.

MAX 20A

30A or less 20A or less

30A or less

Total 30A or less

(RGV13100T)

TWIST

11

Image 14
Contents Generators Contents - 04- Specifications - 1-Performance Curves - 2-General Description of Generator - 3-Control Panel - 4-Serial Number - 5-- 6- Construction and FunctionStator Current Transformer RotorBrush / Brush Holder Diode Unit RGV13100T only- 8- 5 A.V.R Automatic Voltage Regulator RGV12100 onlyECU Electronic Control Unit Idle Control Unit RGV12100 only - 9-Relief Valve OIL Pressure SwitchAC Switch NO-FUSE Breaker - 10-- 11- AC ReceptacleRGV13100T - 12- AC plug Description- 13- Connecting to Domestic Circuit House WiringGfci Receptacle - 14- - 15- AC Three Phase Receptacle RGV13100T only - 16-Voltage Regulating Mechanism RGV12100 Description of Generator OperationPrimary Exciting Action RGV12100 - 17-- 18- Current Transformer Control RGV13100TAdvantages of Current Transformer Control RGV13100T Operate the generator on a level surface Safety PrecautionsDo not place inflammable materials near the generator Do not operate with wet hands or in the rainMotor driven tools and light electrical appliances Incandescent lamp, heater, etc. with a power factorRange of Applications - 20-Appliances without any indication as to power consumption - 21-- 22- - 23- Measuring ProceduresMeasuring Instruments AC Output Measuring - 24-- 25- Measuring Insulation ResistanceStator Current Transformer RGV13100T RotorControl Panel - 26-AC Receptacles Checking Functional MembersPilot Lamp and Voltmeter - 27-RGV12100 - 28-- 29- Rotor AssemblyExciting Coil RGV12100 only Automatic Voltage Regulator BrushA.V.R - 30-Current Transformer RGV13100T only - 31-- 32- Idle Control UnitRGV12100 only - 33- Disassembly Procedures Control Panel Disassembly and AssemblyPreparation and Precautions AlternatorComponent Parts - 35-Generator assembly Control Box RGV12100 Control Box RGV13100T Fuel Tank Generator Assembling Procedures Front Cover - 40-- 41- Rear Cover - 42-- 43- AC Voltage is too high or too low Check engine speed TroubleshootingNo AC output Check if engine is overheatedEngine dose not run - 45-Wiring Diagram - 46-- 47- Lively Blvd. Wood Dale, IL 60191 Phone 630-350-8200 Fax