Subaru Robin Power Products RGV12100, 13100T service manual Engine dose not run, - 45-

Page 48

10-4 Engine dose not run.

Symptom

 

Possible causes

Remedy

 

 

 

 

 

1)

The key switch (or remote

 

 

 

switch) is turned to "START"

Wait for more than 2 seconds and then turn the

 

 

within 2 seconds the engine has

key switch to "START" position.

 

 

been stopped.

 

 

 

 

 

1. Electric starter

2)

The remote controller is con-

Both the key switch of the generator and the

switch of remote controller must be turns into

dose not operate

 

nected.

 

"ON" position.

 

 

 

 

 

 

 

 

3)

The above possible causes 1)

The ECU is defective.

 

 

and 2) dose not apply.

Replace with new one.

 

 

 

 

 

1)

No fuel in the tank or the fuel

Supply fuel or open the fuel cocks.

2. Warning lamp

 

cock is closed.

 

 

turns on and off

 

 

 

when engine is

 

 

 

stopped

2)

Oil level is low or oil is contami-

Add or change engine oil.

 

 

nated.

 

 

 

 

 

 

 

3. Engine is auto-

 

 

 

matically stopped

 

 

 

but the warning

1)

The bulb of warning lamp failed.

Replace the bulb with a new one.

lamp dose not

 

 

 

light up

 

 

 

 

 

 

 

45

Image 48
Contents Generators Contents - 04- Specifications - 1-Performance Curves - 2-General Description of Generator - 3-Control Panel - 4-Serial Number - 5-Construction and Function Stator- 6- Rotor Brush / Brush HolderCurrent Transformer Diode Unit RGV13100T only5 A.V.R Automatic Voltage Regulator RGV12100 only ECU Electronic Control Unit- 8- Idle Control Unit RGV12100 only - 9-OIL Pressure Switch AC Switch NO-FUSE BreakerRelief Valve - 10-AC Receptacle RGV13100T- 11- - 12- AC plug DescriptionConnecting to Domestic Circuit House Wiring Gfci Receptacle- 13- - 14- - 15- AC Three Phase Receptacle RGV13100T only - 16-Description of Generator Operation Primary Exciting Action RGV12100Voltage Regulating Mechanism RGV12100 - 17-Current Transformer Control RGV13100T Advantages of Current Transformer Control RGV13100T- 18- Safety Precautions Do not place inflammable materials near the generatorOperate the generator on a level surface Do not operate with wet hands or in the rainIncandescent lamp, heater, etc. with a power factor Range of ApplicationsMotor driven tools and light electrical appliances - 20-Appliances without any indication as to power consumption - 21-- 22- Measuring Procedures Measuring Instruments- 23- AC Output Measuring - 24-Measuring Insulation Resistance Stator- 25- Rotor Control PanelCurrent Transformer RGV13100T - 26-Checking Functional Members Pilot Lamp and VoltmeterAC Receptacles - 27-RGV12100 - 28-Rotor Assembly Exciting Coil RGV12100 only- 29- Brush A.V.RAutomatic Voltage Regulator - 30-Current Transformer RGV13100T only - 31-Idle Control Unit RGV12100 only- 32- - 33- Disassembly and Assembly Preparation and PrecautionsDisassembly Procedures Control Panel AlternatorComponent Parts - 35-Generator assembly Control Box RGV12100 Control Box RGV13100T Fuel Tank Generator Assembling Procedures Front Cover - 40-- 41- Rear Cover - 42-- 43- Troubleshooting No AC outputAC Voltage is too high or too low Check engine speed Check if engine is overheatedEngine dose not run - 45-Wiring Diagram - 46-- 47- Lively Blvd. Wood Dale, IL 60191 Phone 630-350-8200 Fax