Subaru Robin Power Products Rotor, Control Panel, Current Transformer RGV13100T, - 26-

Page 29

ROTOR

Measure the resistance between the slip ring and the core.

CONTROL PANEL

Measure the insulation resistance between the live parts and the grounded parts.

CURRENT TRANSFORMER (RGV13100T)

Measure the insulation resistance between each terminal and the core.

If it is less than 1MΩ, replace the current transformer.

Any part where the insulation resistance is less than 1MΩ has faulty insulation, and may cause electric leakage and electric shock. Replace the faulty part.

26

Image 29
Contents Generators Contents - 04- - 1- Specifications- 2- Performance Curves- 3- General Description of Generator- 4- Control Panel- 5- Serial Number- 6- Construction and FunctionStator Brush / Brush Holder RotorCurrent Transformer Diode Unit RGV13100T only- 8- 5 A.V.R Automatic Voltage Regulator RGV12100 onlyECU Electronic Control Unit - 9- Idle Control Unit RGV12100 onlyAC Switch NO-FUSE Breaker OIL Pressure SwitchRelief Valve - 10-- 11- AC ReceptacleRGV13100T AC plug Description - 12-- 13- Connecting to Domestic Circuit House WiringGfci Receptacle - 14- - 15- - 16- AC Three Phase Receptacle RGV13100T onlyPrimary Exciting Action RGV12100 Description of Generator OperationVoltage Regulating Mechanism RGV12100 - 17-- 18- Current Transformer Control RGV13100TAdvantages of Current Transformer Control RGV13100T Do not place inflammable materials near the generator Safety PrecautionsOperate the generator on a level surface Do not operate with wet hands or in the rainRange of Applications Incandescent lamp, heater, etc. with a power factorMotor driven tools and light electrical appliances - 20-- 21- Appliances without any indication as to power consumption- 22- - 23- Measuring ProceduresMeasuring Instruments - 24- AC Output Measuring- 25- Measuring Insulation ResistanceStator Control Panel RotorCurrent Transformer RGV13100T - 26-Pilot Lamp and Voltmeter Checking Functional MembersAC Receptacles - 27-- 28- RGV12100- 29- Rotor AssemblyExciting Coil RGV12100 only A.V.R BrushAutomatic Voltage Regulator - 30-- 31- Current Transformer RGV13100T only- 32- Idle Control UnitRGV12100 only - 33- Preparation and Precautions Disassembly and AssemblyDisassembly Procedures Control Panel Alternator- 35- Component PartsGenerator assembly Control Box RGV12100 Control Box RGV13100T Fuel Tank - 40- Generator Assembling Procedures Front Cover- 41- - 42- Rear Cover- 43- No AC output TroubleshootingAC Voltage is too high or too low Check engine speed Check if engine is overheated- 45- Engine dose not run- 46- Wiring Diagram- 47- Lively Blvd. Wood Dale, IL 60191 Phone 630-350-8200 Fax