* Checking table for analogue circuit tester.
Analogue circuit tester |
| Apply black - needle of the circuit tester |
| |||||
|
|
|
|
| ||||
Yellow | Black 1 | White 2 | Light green 3 | Brown 4 orYellow | ||||
|
|
| ||||||
|
|
|
|
|
|
|
| |
| Yellow |
| ∞ | ∞ | ∞ | ∞ | ||
|
|
|
|
|
|
|
| |
Apply red + | Black 1 |
| ∞ | 200 kΩ | ∞ | 300 kΩ | ||
|
|
|
|
|
|
| ||
needle of | White 2 |
| ∞ | 60 kΩ |
| ∞ | 100 kΩ | |
the circuit |
| |||||||
|
|
|
|
|
|
| ||
tester | Light green | 3 | 16 kΩ | 350 kΩ | 125 kΩ |
| 14 kΩ | |
| ||||||||
| Brown 4 orYellow | ∞ | 250 kΩ | 100 kΩ | ∞ | |||
|
|
|
|
|
|
|
|
8-9 CURRENT TRANSFORMER (RGV13100T only)
Disconnect the connectors and couplers of current transformer.
Check the
Terminal number | 1 and 2 | 1 and 3 | 2 and 3 |
|
|
|
|
RGV13100T | 2.00Ω | 2.00Ω | 0.009Ω |
|
|
|
|
If current transformer is found to be faulty, replace with new one.
8-10 ECU (ELECTRONIC CONTROL UNIT)
Check the resistance between 13 terminals of ECU with circuit tester.
1 | 2 | 3 | 4 | 5 | 6 |
13 12 11 10 9 8 7
Terminal number of the ELECTRONIC CON-
TROL UNIT