Subaru Robin Power Products RGV12100, 13100T service manual Specifications, - 1-

Page 4

1. SPECIFICATIONS

 

Model

 

 

RGV12100

 

RGV13100T

 

 

 

 

 

 

 

 

 

Type

 

 

Brush, Self-exciting,

 

Brush, Self-exciting,

 

 

 

2-pole, Single phase

 

2-pole, 3-phase

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated frequency

 

60Hz

 

Alternator

 

 

 

 

 

 

 

Rated voltage

 

 

120V / 240V

 

120V / 208V

 

 

 

 

 

 

 

 

 

 

 

 

Maximum output

 

12000VA

 

13000VA

 

 

 

 

 

 

 

 

 

Rated output

 

 

9500VA

 

10000VA

 

 

 

 

 

 

 

 

 

Power factor

 

 

1.0

 

0.8

 

 

 

 

 

 

 

 

Voltage regulator

 

A.V.R type

 

C.T. type

 

 

 

 

 

 

 

 

 

Model

 

 

EH65D

 

EH63D

 

 

 

 

 

 

 

 

Type

 

 

V-Twin cylinder, Air-cooled, 4-stroke, Overhead valve engine

 

 

 

 

 

 

 

 

Engine

Displacement

 

 

653 cm3

 

 

 

 

 

 

 

 

Maximum output

 

22 HP/ 3600 rpm

 

18 HP/ 3600 rpm

 

 

 

 

 

 

 

 

 

 

 

Fuel

 

 

Unleaded automobile gasoline (RON87 or higher)

 

 

 

 

 

 

 

 

 

Oil capacity

 

 

1.55 liters

 

 

 

 

 

 

 

 

 

 

Starting system

 

 

Electric starter

 

 

 

 

 

 

 

 

 

Fuel tank capacity

 

 

44 liters

 

 

 

 

 

 

 

 

 

Rated continuous

 

3/4 Rated

 

Approx. 9.0 hours

 

Approx. 9.7 hours

operation per a

 

 

 

 

 

 

 

 

 

 

 

 

tankful of fuel

 

Rated

 

Approx. 8.2 hours

 

Approx. 8.9 hours

 

 

 

 

 

 

 

 

Noise level

 

Rated (dB-7m)

 

77.0 dB

 

77.0 dB

 

 

 

 

 

 

 

Dimensions

Height

 

 

771 mm (845 mm *1)

 

Length

 

 

826 mm

 

 

Width

 

 

611 mm (752 mm *1)

 

 

 

 

 

 

 

 

Dry weight

 

 

141 kg (149 kg *2)

 

143 kg (151 kg *2)

 

 

 

 

 

 

 

*1: (

) shows dimensions with castors.

 

 

 

*2: (

) shows dry weight with castors installed.

 

1

Image 4
Contents Generators Contents - 04- Specifications - 1-Performance Curves - 2-General Description of Generator - 3-Control Panel - 4-Serial Number - 5-Stator Construction and Function- 6- Rotor Brush / Brush HolderCurrent Transformer Diode Unit RGV13100T onlyECU Electronic Control Unit 5 A.V.R Automatic Voltage Regulator RGV12100 only- 8- Idle Control Unit RGV12100 only - 9-OIL Pressure Switch AC Switch NO-FUSE BreakerRelief Valve - 10-RGV13100T AC Receptacle- 11- - 12- AC plug DescriptionGfci Receptacle Connecting to Domestic Circuit House Wiring- 13- - 14- - 15- AC Three Phase Receptacle RGV13100T only - 16-Description of Generator Operation Primary Exciting Action RGV12100Voltage Regulating Mechanism RGV12100 - 17-Advantages of Current Transformer Control RGV13100T Current Transformer Control RGV13100T- 18- Safety Precautions Do not place inflammable materials near the generatorOperate the generator on a level surface Do not operate with wet hands or in the rainIncandescent lamp, heater, etc. with a power factor Range of ApplicationsMotor driven tools and light electrical appliances - 20-Appliances without any indication as to power consumption - 21-- 22- Measuring Instruments Measuring Procedures- 23- AC Output Measuring - 24-Stator Measuring Insulation Resistance- 25- Rotor Control PanelCurrent Transformer RGV13100T - 26-Checking Functional Members Pilot Lamp and VoltmeterAC Receptacles - 27-RGV12100 - 28-Exciting Coil RGV12100 only Rotor Assembly- 29- Brush A.V.RAutomatic Voltage Regulator - 30-Current Transformer RGV13100T only - 31-RGV12100 only Idle Control Unit- 32- - 33- Disassembly and Assembly Preparation and PrecautionsDisassembly Procedures Control Panel AlternatorComponent Parts - 35-Generator assembly Control Box RGV12100 Control Box RGV13100T Fuel Tank Generator Assembling Procedures Front Cover - 40-- 41- Rear Cover - 42-- 43- Troubleshooting No AC outputAC Voltage is too high or too low Check engine speed Check if engine is overheatedEngine dose not run - 45-Wiring Diagram - 46-- 47- Lively Blvd. Wood Dale, IL 60191 Phone 630-350-8200 Fax