Briggs & Stratton 01653 owner manual Receptacles, Connecting Electrical Loads, Stopping the Engine

Page 9

Portable Generator

IMPORTANT: Failure to start and operate unit on a level surface will cause the unit not to start or shut down during operation.

2A. For models with the fuel valve built into the engine, turn the fuel valve to the “On” position (Figure 5).

Figure 5 — Fuel Valve

Fuel Valve is shown in the On position

2B. For models with an overhead fuel tank, turn the fuel valve to the “On” position (Figure 6).The fuel valve handle should be vertical (pointing toward the ground) for fuel to flow.

Figure 6 — Fuel Valve

Fuel Valve is shown in the On position

3.Start engine according to instructions given in the engine owner’s manual.

NOTE: If engine starts after 3 pulls but fails to run, or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase.

This unit may be equipped with a low oil protection device. See engine manual.

Connecting Electrical Loads

Let engine stabilize and warm up for a few minutes after starting.

Plug in and turn on the desired 120 and/or 240 Volt AC, single phase, 60 Hz electrical loads.

DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles.

DO NOT connect 3–phase loads to the generator.

DO NOT connect 50 Hz loads to the generator.

DO NOT OVERLOAD THE GENERATOR. See “Don’t Overload the Generator” on page 11.

2.Let engine run at no-load for several minutes to stabilize internal temperatures of engine and generator.

3.Turn engine off according to instructions given in the engine owner’s manual.

4.Move fuel valve to “Off” position.

RECEPTACLES

The generator will be equipped with one or more of the following receptacles:

CAUTION

Receptacles may be marked with rating value greater than generator output capacity.

NEVER attempt to power a device requiring more amperage than generator or receptacle can supply.

DO NOT overload the generator. See “Don’t Overload Generator”.

120/240 Volt AC, 30 Amp, Locking Receptacle

Use a NEMA L14–30 plug with this receptacle. Connect a 4–wire cord set rated for 250 Volt AC loads at 30 Amps (or greater) (Figure 7).You can use the same 4–wire cord if you plan to run a 120 Volt load.

Figure 7 — 120/240 Volt AC, 30 Amp Receptacle

4-Wire Cord Set

240V

120V 120V

W (Neutral)

Y (Hot)

X (Hot)

NEMA L14-30

Ground (Green)

Stopping the Engine

1.Unplug all electrical loads from generator panel receptacles. Never start or stop engine with electrical devices plugged in and turned ON.

This receptacle powers 120/240 Volt AC, 60 Hz, single phase loads requiring up to 6,000 watts of power (6.0 kW) at 30 Amps for 120 Volts or 240 Volts.The outlet is protected by a push–to–reset circuit breaker.

9

Image 9
Contents 01653 3250W 01654 5500W 01892 5000W 01893 6000W Safety Rules Table of ContentsHazard Symbols and Meanings Equipment DescriptionWhen Operating Equipment When Adding FuelWhen Transporting or Repairing Equipment When Storing Fuel or Equipment with Fuel in TankWhen Adjusting or Making Repairs to Your Generator Assembly Install Wheel KITInstall the 10 Wheel Kit as Follows Installing the Wheel Kit Install the 8 Wheel Kit as FollowsTo install Check Battery / Attach Negative Battery WireElectric Start Before Starting the EngineUsing the Generator Battery ChargerOperating Generator Receptacles Connecting Electrical Loads120/240 Volt AC, 30 Amp, Locking Receptacle Stopping the EngineCold Weather Operation Volt AC, 30 Amp Locking ReceptacleVolt AC, 20 Amp, Duplex Receptacles Dont Overload Generator Power ManagementCapacity ExampleEngine Maintenance General Maintenance RecommendationsGenerator Maintenance Battery MaintenanceStorage Generator StorageEngine Storage Other Storage Tips Problem Cause Correction TroubleshootingLimited Warranty Table DES Matières Symboles de Danger et MoyensDescription DE L Équipement Règles DE SécuritéLorsque Vous Ajoutez DU Carburant Lorsque Léquipement FonctionneLorsque Vous Transportez OU Réparez Léquipement Lorsque Vous Réglez OU Réparez Votre Générateur Installe LA Roue LA Trousse Installez les roues de 25 cm 10 po comme suit figureAssemblage Installez les roues de 20 cm 8 po comme suit figure Démarrage Électrique InstallationAvant LE Démarrage DU Moteur Ajouter de lhuile à moteur et du combustibleUtilisation DE LA Génératrice Chargeur DE BatterieUtilisation DU Générateur Branchement des Charges Électriques Prises DE CourantArrêt du Moteur Prise à Verrouillage de 120/240 Volts c.a., 30 AmpèresExploitation PAR Temps Froid Prise à Verrouillage de 120 Volts c.a., 30 AmpèresVolts c.a., 20 Ampères Prise de Courant Double Capacité NE PAS Surchargez GénérateurGestion de la Consommation ExempleEntretien du Moteur Recommandations Générales D’ENTRETIENEntretien du Générateur Entretien de la BatterieRemisage du Générateur RemisageRemisage du Moteur Autres Idées de RemisageDépannage Garantie Limitée Descripción DEL Equipo Tabla DE ContenidosInstrucciones DE Seguridad AdvertenciaCuando Añada Combustible PeligroCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónInstale EL Juego DE Ruedas MontajeFigura 24 Instale el Juego de Ruedas Instale el 8 Juego de Ruedas Como Sigue FiguraAntes DE Darle Arranque AL Motor Arranque EléctricoAgregar Aceite al Motor y Gasolina Para instalarUSO DEL Generador Cargador DE BateríaOperando EL Generador Precaución Conexion De Cargas Electricas ReceptáculosParado Del Motor 120/240 Voltios AC, 30 Amp, Receptáculo de SeguridadTomacorrientes de 120 Voltios AC, 30 Amperios Volt AC, 20 Amp, Receptáculos DoblesOperación Durante un Clima Frío Capacidad No Sobrecargue GeneradorControl de la Energía EjemploMantenimiento del Motor Recomendaciones Generales DE MantenimientoMantenimiento del Generador Mantenimiento de la BateríaAlmacenando el Generador AlmacenamientoAlmacenando el Motor Otras Sugerencias Para el AlmacenandoDiagnositicos DE Averías Problemo Accion CausaNotas Garantía Limitada

01654, 01653, 01892, 01893, 01653, 01653, 01654, 01892, 01893 specifications

Briggs & Stratton is a renowned name in the power equipment industry, particularly recognized for its reliable small engines used in various applications. The model numbers 01653, 01654, 01892, and 01893 represent a series of advanced engines that embody the innovation and quality synonymous with the Briggs & Stratton brand.

One of the main features of these models is their robust design, which ensures durability and longevity even under demanding conditions. Engineered for easy operation, these engines are ideal for both residential and commercial applications, such as lawn mowers, pressure washers, and generators.

The 01653 and 01654 models are equipped with overhead valve technology, providing enhanced fuel efficiency and reduced emissions. This allows users to operate their equipment more sustainably while still experiencing powerful performance. Additionally, both models feature a convenient recoil starter, making them easy to start with minimal effort.

Moving on to the 01892 and 01893 models, these engines incorporate advanced cooling systems designed to prevent overheating during extended use. This is particularly beneficial for users who rely on their equipment for long periods, as it enhances performance and reliability. The 01892 model also boasts a unique float feed carburetor system, which ensures consistent fuel delivery, optimizing engine performance regardless of the application's rigor.

All four models are designed with user-friendliness in mind. They come equipped with simple maintenance features, allowing users to perform routine checks and oil changes with ease. The easy-access air filters contribute to better engine performance and longevity while being straightforward to replace.

Furthermore, Briggs & Stratton engines are field-tested for their reliability and efficiency. Users can trust that every one of these models delivers consistent power and performance, which is critical for completing tasks efficiently.

In conclusion, the Briggs & Stratton 01653, 01654, 01892, and 01893 models stand out due to their advanced technologies, user-friendly features, and robust construction. They represent the company's commitment to providing dependable engines that meet the varied needs of professionals and homeowners alike. Whether for residential or commercial use, these models continue to set standards in the power equipment industry.