Performance

(10 Ton)

Data

High Efficiency

 

 

 

 

Table PD-54— Belt Drive Evaporator Fan Performance — 10-Ton — THC120A3,A4,AW —Horizontal Airflow

 

 

 

 

 

 

 

 

 

External Static Pressure (Inches of Water)

 

 

 

 

 

 

 

 

 

.10

 

.20

 

.30

 

.40

.50

 

.60

 

 

.70

 

.80

 

.90

 

1.00

CFM

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

 

 

 

 

 

 

3-HP Standard Motor & Field Supplied

 

 

 

 

 

 

 

 

3-HP Standard Motor

 

 

 

 

 

 

Low Static Drive (1)

 

 

 

 

 

 

 

 

 

 

& Drive

 

 

3200

 

748

1.06

787

1.19

824

1.32

864

1.47

 

906

1.64

946

1.81

983

1.97

1015

2.13

3600

746

1.18

777

1.27

811

1.39

849

1.54

883

1.68

916

1.82

 

950

1.98

987

2.16

1024

2.35

1060

2.55

4000

822

1.59

850

1.70

879

1.81

912

1.95

946

2.12

977

2.28

 

1006

2.43

1035

2.60

1067

2.79

1101

2.99

4400

898

2.09

925

2.21

950

2.32

977

2.46

1008

2.63

1039

2.81

 

1067

2.98

1094

3.16

1121

3.33

1147

3.52

4800

 

974

2.69

1000

2.83

1023

2.95

1046

3.07

1072

3.23

1101

3.42

 

1130

3.62

1156

3.81

1181

4.00

1206

4.19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-HP Oversized Motor & Drive

 

 

 

For Standard Evaporator Fan Speed (RPM), reference Table PD-50.

NOTES:

Data includes pressure drop due to standard filters and wet coils. No accessories or options are included in pressure drop data.

Refer to Table PD-54 to determine additional static pressure drop due to other options/accessories 3-HP Fan Motor Heat (MBH) = 2.900 x Fan BHP+.475.

5-HP Fan Motor Heat (MBH) = 2.950 x Fan BHP+.470.

1.Field Supplied Motor Sheave 1VM50 x 7/8 inch, Fan Sheave AK89, and Belt AX40 required

Trane’s factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product’s warranty will not be affected.

Table PD-54 — Continued

 

 

 

 

 

 

 

 

External Static Pressure (Inches of Water)

 

 

 

 

 

 

 

 

 

 

 

1.10

 

1.20

 

1.30

 

1.40

1.50

1.60

 

1.70

1.80

1.90

2.00

CFM

 

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

 

 

 

 

3-HP Standard Motor & Drive

 

 

 

 

 

 

 

 

 

 

 

 

 

3200

1044

2.28

1072

2.42

1097

2.57

1122

2.71

1145

2.84

1168

2.99

1189

3.12

1210

3.27

1231

3.41

1250

3.54

3600

1093

2.74

1124

2.92

1151

3.09

1176

3.25

1201

3.42

1224

3.58

1246

3.74

1268

3.90

1289

4.06

1308

4.20

4000

1135

3.21

1167

3.42

1198

3.63

1227

3.84

1254

4.05

1278

4.23

1301

4.41

1323

4.60

1344

4.77

1365

4.95

4400

 

1177

3.73

1207

3.96

1239

4.19

1268

4.42

1297

4.67

1324

4.90

1351

5.12

1376

5.35

1398

5.56

1420

5.75

4800

1229

4.39

1254

4.59

1282

4.83

1310

5.07

1338

5.32

1365

5.58

5-HP Oversized Motor & Drive

Table PD-55— Belt Drive Evaporator Fan Performance — 10-Ton — THC120A3,A4,AW —Horizontal Airflow — Dehumidification (Hot Gas Reheat)

 

 

 

 

 

 

 

 

 

External Static Pressure (Inches of Water)

 

 

 

 

 

 

 

 

 

 

 

 

.10

 

.20

.30

 

.40

 

.50

 

 

.60

 

.70

 

.80

 

.90

 

1.00

 

CFM

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

 

 

 

 

 

 

 

3-HP Standard Motor & Low

 

 

 

3-HP Standard Motor & Low

 

 

 

 

 

2000

 

584

Static DriveAccessory Kit (1)

721

0.71

Static DriveAccessory Kit (2)

818

0.97

849

1.06

 

 

0.43

639

0.53

682

0.62

755

0.79

787

0.88

 

 

2400

 

578

0.48

627

0.57

683

0.70

734

0.83

776

0.94

812

1.05

845

1.15

 

876

1.26

904

1.36

 

2800

 

596

0.58

640

0.67

686

0.79

728

0.90

776

1.04

822

1.19

865

1.34

900

1.47

 

932

1.60

962

1.73

 

3200

671

0.85

706

0.93

748

1.06

787

1.19

824

1.32

864

1.47

906

1.64

946

1.81

 

983

1.97

1015

2.13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-HP Oversized Motor & Drive

***MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT IS 3200 CFM.

NOTES:

Data includes pressure drop due to standard filters and wet coils. Data does not include pressure drop due to reheat coil.

3-HP Fan Motor Heat (MBH) = 2.900 x Fan BHP+.475.

1.BAYLSDR010ARequired.

2.BAYLSDR010ARequired.

Trane’s factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor failure. Our product’s warranty will notbeaffected.

Table PD-55 — Continued

 

 

 

 

 

 

 

 

External Static Pressure (Inches of Water)

 

 

 

 

 

 

 

 

 

 

 

 

1.10

 

1.20

 

1.30

 

1.40

1.50

1.60

 

1.70

1.80

1.90

2.00

 

CFM

 

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

 

3-HP Standard Motor & Low

 

 

 

 

3-HP Standard Motor & Drive

 

 

 

 

 

 

 

 

 

Static DriveAccessory Kit (2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2000

877

1.15

906

1.24

933

1.33

961

1.43

988

1.54

1014

1.64

1038

1.74

1063

1.85

1087

1.96

1111

2.07

 

2400

 

931

1.47

958

1.58

983

1.68

1008

1.78

1032

1.89

1056

2.00

1080

2.11

1103

2.22

1126

2.34

1149

2.46

 

2800

989

1.84

1015

1.97

1040

2.09

1064

2.21

1087

2.34

1110

2.46

1132

2.58

1154

2.71

1176

2.83

1196

2.95

 

3200

1044

2.28

1072

2.42

1097

2.57

1122

2.71

1145

2.84

1168

2.99

1189

3.12

1210

3.27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

44

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RT-PRC005-EN

Page 44
Image 44
Trane RT-PRC005 manual Table PD-54, Table PD-55, HP Standard Motor & Low, Static DriveAccessory Kit