Table PD-15 — Gross Cooling Capacities (MBH) 6Ton Three Phase THC072A3, A4, AW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AmbientTemperature (F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

 

 

 

 

 

 

 

 

 

95

 

 

 

 

 

 

 

 

 

105

 

 

 

 

 

 

 

 

115

 

 

 

 

 

Enter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EnteringWet Bulb (F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

Bulb

61

 

67

 

73

 

 

 

61

 

67

 

73

 

 

 

61

 

67

 

73

 

 

61

 

67

 

73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

(F)

MBH SHC MBH SHC MBH SHC

MBH SHC MBH SHC MBH

SHC

MBH

SHC MBH SHC MBH SHC

 

MBH SHC

 

MBH SHC

 

MBH SHC

 

 

75

67.3

56.6

73.6

42.5

74.5

27.6

 

61.6

53.5

71.8

41.9

75.1

26.6

 

55.8

50.4

66.8

38.7

74.1

25.3

 

49.8

47.2

59.9

36.3

71.3

23.5

2160

80

68.7

68.2

73.8

51.7

75.4

37.0

 

63.6

63.6

72.0

52.1

76.0

38.1

 

58.9

58.9

66.9

49.7

74.7

36.4

 

54.1

54.1

60.2

46.5

71.5

34.5

85

72.2

72.2

74.5

61.4

76.2

44.5

 

69.2

69.2

72.5

62.8

76.8

46.1

 

64.6

64.6

67.8

60.9

75.0

46.2

 

59.5

59.5

61.3

57.7

71.7

45.4

 

 

 

 

 

90

74.7

74.7

75.3

70.6

77.0

51.9

 

73.4

73.4

73.7

73.2

77.7

55.1

 

70.1

70.1

70.1

70.1

75.6

56.1

 

65.4

65.4

65.4

65.4

72.1

55.8

 

75

69.0

60.1

74.0

43.3

74.5

27.9

 

63.5

57.2

72.7

43.1

75.2

27.0

 

57.5

54.0

68.4

40.9

74.5

25.7

 

51.8

51.0

61.5

37.6

72.0

24.0

2400

80

70.7

70.7

74.3

52.9

75.4

37.2

 

66.8

66.8

73.0

54.6

76.2

37.8

 

61.9

61.9

68.7

53.0

75.1

37.4

 

56.7

56.7

61.9

49.8

72.4

36.1

85

73.8

73.8

75.0

63.0

76.2

44.9

 

71.9

71.9

73.8

66.0

77.1

47.0

 

67.9

67.9

69.7

65.4

75.5

47.5

 

62.7

62.7

63.6

62.4

72.6

47.7

 

 

 

 

 

90

75.6

75.6

75.9

72.4

77.0

52.5

 

75.2

75.2

75.1

75.1

78.0

56.3

 

72.8

72.8

72.7

72.7

76.4

58.2

 

68.8

68.8

68.8

68.8

73.2

59.0

 

75

70.3

63.2

74.2

43.9

74.6

28.3

 

65.2

60.8

73.2

44.5

75.4

27.4

 

59.2

57.7

69.6

42.9

74.7

26.2

 

53.2

53.2

62.9

39.8

72.5

24.6

2640

80

72.3

72.3

74.5

53.9

75.4

37.4

 

69.5

69.5

73.8

56.7

76.3

38.2

 

64.6

64.6

70.0

56.1

75.6

38.5

 

59.2

59.2

63.5

53.0

73.0

37.7

85

74.7

74.7

75.3

64.3

76.2

45.2

 

73.7

73.7

74.7

68.7

77.3

47.6

 

70.5

70.5

71.3

69.3

76.1

48.9

 

65.6

65.6

65.6

65.6

73.4

49.7

 

 

 

 

 

90

76.1

76.1

76.2

73.6

76.9

53.0

 

76.2

76.2

76.2

76.2

78.1

57.2

 

74.5

74.5

74.5

74.5

76.9

59.9

 

71.2

71.2

71.2

71.2

74.1

61.7

 

75

71.3

65.8

74.3

44.4

74.6

28.7

 

66.8

64.4

73.7

45.6

75.5

27.8

 

60.5

60.5

70.6

44.8

74.9

26.6

 

55.1

55.1

64.1

41.8

72.9

25.0

2880

80

73.3

73.3

74.7

54.8

75.4

37.6

 

71.4

71.4

74.4

58.5

76.4

38.5

 

67.0

67.0

71.0

58.9

75.9

39.1

 

61.4

61.4

64.9

56.2

73.3

38.6

85

75.1

75.1

75.5

65.3

76.2

45.6

 

74.8

74.8

75.4

70.8

77.4

48.2

 

72.4

72.4

72.4

72.4

76.4

49.9

 

68.2

68.2

68.1

68.1

74.0

51.5

 

 

 

 

 

90

76.3

76.3

76.3

74.5

76.9

53.5

 

76.9

76.9

76.9

76.9

78.2

58.0

 

75.7

75.7

75.7

75.7

77.2

61.3

 

72.9

72.9

72.9

72.9

74.8

64.1

NOTES:

1.All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.

2.MBH = Total Gross Capacity

3.SHC = Sensible Heat Capacity

Table PD-16 — Gross Cooling Capacities (MBH) 7½ Ton Three Phase THC092A3, A4, AW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AmbientTemperature (F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

 

 

 

 

 

 

 

 

 

 

95

 

 

 

 

 

 

 

 

 

 

105

 

 

 

 

 

 

 

 

 

115

 

 

 

 

 

Enter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EnteringWet Bulb (F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

Bulb

61

 

67

 

73

 

 

61

 

67

 

73

 

 

 

61

 

67

 

73

 

 

61

 

67

 

73

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

(F)

 

 

MBH

SHC

 

 

MBH

SHC

 

 

MBH SHC

 

 

 

MBH SHC

 

MBH SHC

 

 

MBH SHC

 

 

MBH SHC

 

MBH SHC

 

 

MBH SHC

 

 

MBH SHC

 

MBH SHC

 

MBH SHC

 

 

75

85.7

72.4

95.8

56.8

99.9

37.1

79.3

69.3

92.0

53.7

98.8

35.8

 

72.8

66.0

85.9

50.8

96.1

34.2

 

66.1

62.6

78.5

49.1

91.8

32.2

2700

80

87.5

87.0

96.2

68.5

101.1

50.4

81.8

81.8

92.4

67.4

99.6

50.2

 

76.6

76.6

86.2

64.6

96.7

48.0

 

71.1

71.1

79.0

61.4

92.0

45.8

85

92.8

92.8

97.0

81.6

102.3

61.3

88.5

88.5

93.1

81.1

100.3

61.3

 

83.4

83.4

87.1

78.6

97.0

60.9

 

77.9

77.9

80.3

75.4

92.3

59.4

 

 

 

 

90

97.2

97.2

98.3

94.2

103.5

72.4

94.3

94.3

94.3

94.3

101.1

73.1

 

90.0

90.0

90.0

90.0

97.8

73.7

 

84.9

84.9

84.9

84.9

92.9

72.7

 

75

87.9

77.0

96.6

57.3

100.4

37.6

81.5

73.7

93.5

56.1

99.4

36.4

 

74.9

70.5

87.8

53.4

96.9

34.8

 

67.4

67.4

80.5

50.2

92.8

32.8

3000

80

90.5

90.5

97.4

71.2

101.6

51.1

85.6

85.6

94.0

71.0

100.4

50.9

 

80.2

80.2

88.2

68.7

97.3

49.8

 

74.5

74.5

81.0

65.5

93.2

47.9

85

95.6

95.6

98.4

85.1

102.9

62.5

92.2

92.2

95.0

85.8

101.3

63.3

 

87.3

87.3

89.5

84.1

98.1

63.3

 

81.8

81.8

82.9

81.2

93.6

62.5

 

 

 

 

90

99.4

99.4

99.9

98.1

104.1

74.1

97.2

97.2

97.2

97.2

102.1

75.5

 

93.6

93.6

93.5

93.5

99.1

77.0

 

88.8

88.8

88.7

88.7

94.4

76.9

 

75

89.8

81.3

97.5

59.0

100.7

38.1

83.6

78.2

94.6

58.3

99.8

37.1

 

77.0

75.0

89.2

55.9

97.5

35.4

 

70.0

70.0

82.1

52.8

93.6

33.4

3300

80

93.2

93.2

98.3

73.5

102.0

51.7

88.9

88.9

95.2

74.2

101.0

52.0

 

83.4

83.4

89.8

72.6

97.9

50.6

 

77.6

77.6

82.8

69.5

94.1

49.9

85

97.6

97.6

99.4

88.0

103.3

67.9

94.9

94.9

96.5

90.0

101.9

64.8

 

90.5

90.5

91.7

89.4

99.0

67.3

 

85.2

85.2

85.1

85.1

94.7

65.2

 

 

 

 

90

100.9 100.9 100.9 100.9 104.6

75.6

99.2

99.2

99.2

99.2

102.8

77.7

 

96.1

96.1

96.1

96.1

100.1

80.0

 

91.8

91.8

91.8

91.8

95.7

80.7

 

75

91.5

85.3

98.2

60.6

101.0

38.6

85.5

82.6

95.4

60.2

100.2

37.5

 

78.5

78.5

90.5

58.3

98.0

35.9

 

72.4

72.4

83.4

55.2

94.3

34.0

3600

80

95.2

95.2

99.0

75.4

102.3

56.8

91.5

91.5

96.3

77.2

101.5

52.7

 

86.3

86.3

91.3

76.3

98.4

51.4

 

80.4

80.4

84.4

73.4

94.7

51.4

85

99.1

99.1

100.2

90.6

103.6

69.8

96.9

96.9

97.8

93.6

102.4

66.1

 

93.1

93.1

93.1

93.1

99.7

69.8

 

88.0

88.0

87.9

87.9

95.6

67.8

 

 

 

 

90

101.9 101.9 101.9 101.9

105.0

76.9

100.7 100.7 100.7 100.7 103.4

79.6

 

98.0

98.0

97.9

97.9

100.8

82.5

 

94.0

94.0

94.0

94.0

96.7

84.1

NOTES:

1.All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.

2.MBH = Total Gross Capacity

3.SHC = Sensible Heat Capacity

RT-PRC005-EN