Briggs & Stratton bsp5500l Table Of Contents, Equipment Description, Safety Rules, Danger

Page 2
BSP5500L Generator

BSP5500L Generator

TABLE OF CONTENTS

Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3

Know Your Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8

Product Specifications / Maintenance . . . . . . . . . . . . . . . . 9

Storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 & 17

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Schematic/Wiring Diagram . . . . . . . . . . . . . . . . . . . . 12-13

Replacement Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . 14-16

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Last Page

EQUIPMENT

DESCRIPTION

Read this manual carefully and become familiar with your generator. Know its applications, its limitations and any hazards involved.

This generator is an engine–driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliances, tools and motor loads.The generator’s revolving field is driven at about 3,600 rpm by a single-cylinder engine.

CAUTION! Do Not exceed the generator’s wattage/amperage capacity. See “Don’t Overload the Generator” on page 8.

Every effort has been made to ensure that information in this manual is accurate and current. However, Briggs & Stratton reserves the right to change, alter or otherwise improve the product and this document at any time without prior notice. The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency. For warranty information refer to the engine owner’s manual.

SAFETY RULES

The safety alert symbol (TABLE OF CONTENTS) is used with a signal word (DANGER, CAUTION,WARNING), a pictorial and/or a safety message to alert you to hazards. DANGER indicates a hazard which, if not avoided, will result in death or serious injury. WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. CAUTION, when used without the alert symbol, indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death.

EQUIPMENT WARNING

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

SAFETY RULES DANGER

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide will cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep at least 2 feet of clearance on all sides of generator for adequate ventilation.

Do not operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).

 DANGER DANGER

Failure to properly ground generator can result in electrocution, especially if the generator is equipped with a wheel kit.

National Electric Code requires generator to be properly grounded to an approved earth ground. Call an electrician for local grounding requirements.

Manual background DANGER

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground circuit fault interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

Do not touch bare wires or receptacles.

Do not use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

Do not operate generator in the rain.

Do not handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

Do not allow unqualified persons or children to operate or service generator.

2

Image 2
Contents Perguntas? Questions?Preguntas? BSP5500LEQUIPMENT DESCRIPTION TABLE OF CONTENTSSAFETY RULES DANGERFire or explosion can cause severe burns or death KNOW YOUR GENERATOR Add Gasoline BEFORE STARTING THE ENGINEAdd Oil OPERATING THE GENERATOR GROUNDING THEGENERATOR Starting the EngineStopping the Engine Connecting Electrical LoadsRECEPTACLES 120/240 Volt AC, 30 Amp, Locking ReceptacleCapacity Power ManagementDONT OVERLOAD YOUR GENERATOR To Clean the Generator SPECIFICATIONSGENERAL MAINTENANCE RECOMMENDATIONS Engine MaintenanceBSP5500L Generator Solution TROUBLESHOOTINGProblem CauseSCHEMATIC WIRING DIAGRAM EXPLODED VIEW - MAIN UNIT PARTS LIST - MAIN UNIT Qty DescriptionEXPLODED VIEW AND PARTS LIST - CONTROL PANEL BSP5500L Generator INSTRUCCIONES DE SEGURIDAD TABLA DE CONTENIDOSDESCRIPCIÓN DEL EQUIPO ADVERTENCIAPRECAUCIÓN CONOZCA SU GENERADOR Agregue Gasolina ANTES DE DARLE ARRANQUE AL MOTORAgregar Aceite al Motor Encienda el Motor CONEXION A TIERRA DEL GENERADOROPERANDO EL GENERADOR Parado Del Motor RECEPTÁCULOSConexion De Cargas Electricas 120 Volt AC, 20 Amp, Receptáculos DoblesControl de la Energía NO SOBRECARGUE EL GENERADORCapacidad ALMACENAMIENTO ESPECIFICACIONESRECOMENDACIONES GENERALES DE MANTENIMIENTO Mantenimiento del MotorNOTAS Causa ProblemoDIAGNOSITICOS DE AVERÍAS AccionREGRAS DE SEGURANÇA ÍNDICEDESCRIÇÃO DO EQUIPAMENTO ATENÇÃOCUIDADO CONHEÇA SEU GERADOR Abasteça de Gasolina ANTES DE DAR A PARTIDA NO MOTORAbasteça de Óleo Partida do Motor ATERRAMENTO DO GERADOROPERAÇÃO DO GERADOR Conexão das Cargas ElétricasTomada com Trava120/240 V CA, 30 A TOMADASParada do Motor Tomada Duplex 120 V CA, 20 ACapacidade Administração da PotênciaNÃO SOBRECARREGUE SEU GERADOR ARMAZENAMENTO ESPECIFICAÇÕESRECOMENDAÇÕES DE MANUTENÇÃO Limpeza do GeradorNOTAS Correção SOLUÇÃO DE PROBLEMASProblema Válidos desde 1 de junho de GARANTIA LIMITADAPRAZO DE GARANTIA EquipamentoEfectiva desde el 1ro de Junio, GARANTÍA LIMITADA PERIODO DE GARANTÍAEquipo Para Uso Del ConsumidorAbout your equipment warranty LIMITED WARRANTYWARRANTY PERIOD Equipment