Briggs & Stratton bsp5500l Troubleshooting, Problem, Cause, Solution, BSP5500L Generator

Page 11
TROUBLESHOOTING

BSP5500L Generator

TROUBLESHOOTING

Problem

Cause

Solution

 

1.

Circuit breaker is open.

1.

Reset circuit breaker.

Engine is running, but

2.

Poor connection or defective cord set.

2.

Check and repair.

3.

Connected device is bad.

3.

Connect another device that is in good

no AC output is

 

 

 

condition.

available.

 

 

 

4.

Fault in generator.

4.

Contact Briggs and Stratton service

 

 

 

 

 

facility.

 

1.

Short circuit in a connected load.

1.

Disconnect shorted electrical load.

 

2.

Generator is overloaded.

2.

See “Don’t Overload the Generator” on

Engine runs good but

 

 

 

page 8.

bogs down when

3.

Engine speed is too slow.

3.

Contact Briggs and Stratton service

loads are connected.

 

 

 

facility.

 

4.

Shorted generator circuit.

4.

Contact Briggs and Stratton service

 

 

 

 

facility.

 

1.

Rocker switch set to “Off”.

1.

Set switch to “On”.

 

2.

Fuel valve is in the “Closed” position.

2.

Turn fuel valve to the “Open” position.

 

3.

Low oil level.

3.

Fill crankcase to proper level.

 

4.

Dirty air cleaner.

4.

Clean or replace air cleaner.

 

5.

Out of gasoline.

5.

Fill fuel tank.

 

6.

Stale gasoline.

6.

Drain gas tank and fill with fresh fuel.

Engine will not start;

7.

Spark plug wire not connected to

7.

Connect wire to spark plug.

 

spark plug.

 

 

or starts and runs

8.

Bad spark plug.

8.

Replace spark plug.

rough.

9.

Water in gasoline.

9.

Drain gas tank; fill with fresh fuel.

 

10.

Overchoking.

10.

Set choke to “Off” position.

 

11.

Excessively rich fuel mixture.

11.

Contact Briggs and Stratton service

 

 

 

 

facility.

 

12.

Intake valve stuck open or closed.

12.

Contact Briggs and Stratton service

 

 

 

 

facility.

 

13.

Engine has lost compression.

13.

Contact Briggs and Stratton service

 

 

 

 

facility.

Engine shuts down

1.

Out of gasoline.

1.

Fill fuel tank.

2.

Fault in engine.

2.

Contact Briggs and Stratton service

during operation.

 

 

 

facility.

 

 

 

 

 

1.

Load is too high.

1.

See “Don’t Overload the Generator” on

Engine lacks power.

 

 

 

page 8.

 

2.

Dirty air filter.

2.

Replace air filter.

 

 

 

 

 

 

1.

Choke is opened too soon.

1.

Move choke to halfway position till engine

Engine “hunts” or

 

 

 

runs smoothly.

falters.

2.

Carburetor is running too rich or too

2.

Contact Briggs and Stratton service

 

 

lean.

 

facility.

11

Image 11
Contents BSP5500L Questions?Preguntas? Perguntas?DANGER TABLE OF CONTENTSSAFETY RULES EQUIPMENT DESCRIPTIONFire or explosion can cause severe burns or death KNOW YOUR GENERATOR Add Gasoline BEFORE STARTING THE ENGINEAdd Oil Starting the Engine GROUNDING THEGENERATOR OPERATING THE GENERATOR120/240 Volt AC, 30 Amp, Locking Receptacle Connecting Electrical LoadsRECEPTACLES Stopping the EngineCapacity Power ManagementDONT OVERLOAD YOUR GENERATOR Engine Maintenance SPECIFICATIONSGENERAL MAINTENANCE RECOMMENDATIONS To Clean the GeneratorBSP5500L Generator Cause TROUBLESHOOTINGProblem SolutionSCHEMATIC WIRING DIAGRAM EXPLODED VIEW - MAIN UNIT Qty Description PARTS LIST - MAIN UNITEXPLODED VIEW AND PARTS LIST - CONTROL PANEL BSP5500L Generator ADVERTENCIA TABLA DE CONTENIDOSDESCRIPCIÓN DEL EQUIPO INSTRUCCIONES DE SEGURIDADPRECAUCIÓN CONOZCA SU GENERADOR Agregue Gasolina ANTES DE DARLE ARRANQUE AL MOTORAgregar Aceite al Motor Encienda el Motor CONEXION A TIERRA DEL GENERADOROPERANDO EL GENERADOR 120 Volt AC, 20 Amp, Receptáculos Dobles RECEPTÁCULOSConexion De Cargas Electricas Parado Del MotorControl de la Energía NO SOBRECARGUE EL GENERADORCapacidad Mantenimiento del Motor ESPECIFICACIONESRECOMENDACIONES GENERALES DE MANTENIMIENTO ALMACENAMIENTONOTAS Accion ProblemoDIAGNOSITICOS DE AVERÍAS CausaATENÇÃO ÍNDICEDESCRIÇÃO DO EQUIPAMENTO REGRAS DE SEGURANÇACUIDADO CONHEÇA SEU GERADOR Abasteça de Gasolina ANTES DE DAR A PARTIDA NO MOTORAbasteça de Óleo Conexão das Cargas Elétricas ATERRAMENTO DO GERADOROPERAÇÃO DO GERADOR Partida do MotorTomada Duplex 120 V CA, 20 A TOMADASParada do Motor Tomada com Trava120/240 V CA, 30 ACapacidade Administração da PotênciaNÃO SOBRECARREGUE SEU GERADOR Limpeza do Gerador ESPECIFICAÇÕESRECOMENDAÇÕES DE MANUTENÇÃO ARMAZENAMENTOBSP5500L Gerador Correção SOLUÇÃO DE PROBLEMASProblema Equipamento GARANTIA LIMITADAPRAZO DE GARANTIA Válidos desde 1 de junho dePara Uso Del Consumidor PERIODO DE GARANTÍAEquipo Efectiva desde el 1ro de Junio, GARANTÍA LIMITADAEquipment LIMITED WARRANTYWARRANTY PERIOD About your equipment warranty