Intel SE7500CW2 manual Attaching the Heat Sink Fan, Attaching Intake and Exhaust Assemblies

Page 59

Attaching the Heat Sink Fan

Attach the fan to the wind tunnel air intake section as shown in Figure 16. The fan label (Figure 16, A) must point into the air intake section.

A

OM14476

Figure 16. Attaching the Heat Sink Fan

Attaching Intake and Exhaust Assemblies

NOTE

System airflow should be from front to back. Make sure the wind tunnel is aligned so the fan is toward the front of the chassis and the airflow is toward the I/O shield. If two processors are installed, the fans should be side by side.

1.Attach the air intake fan assembly to the side of the heat sink wind tunnel nearest to the front of the chassis. Align the tabs on the assembly with the slots in the wind tunnel section, then snap the lower portion of the fan holder over the tabs on the center section.

2.Attach the exhaust portion of the processor wind tunnel assembly.

3.Attach CPU Fan 1 cable to the server board at location J15 and/or attach CPU Fan 2 cable at location J16.

OM14477

Figure 17. Attaching Intake and Exhaust Assemblies

Server Board Installation

59

Image 59
Contents Intel Server Board SE7500CW2 Product Guide Disclaimer Contents Upgrading Solving ProblemsIndex Technical ReferenceRegulatory and Integration Information Tables Description Server Board FeaturesServer Board Features FeatureSystem I/O Power Security Form Factor Back Panel Connectors Back Panel ConnectorsServer Board Connector and Component Locations Server Board Connector and Component LocationsBoxed Processor Fan Heat sink ProcessorDual Processor Operation MCH Intel E7500 ChipsetParallel Port Keyboard and Mouse ConnectorsSuper I/O Serial PortsPCI I/O Subsystem MemoryBit / 100 MHz PCI-X Capable Subsystem Bit / 133 MHz PCI-X Capable Subsystem32-bit/33 MHz PCI Subsystem Video ControllerNetwork Interface Controller NIC Wake on LAN AC Link ModeSecurity Operation Summary Password ProtectionSecurity Using Passwords Password Clear JumperIntel Server Board SE7500CW2 Product Guide Description and brief procedure Configuration Software and UtilitiesPower-On Self-Test Post Configuration UtilitiesSetup Menus Using Bios Setup UtilityIf You Cannot Access Setup Starting SetupPress Keyboard CommandsMenu Selection Bar Main Advanced Security Power Boot SystemMenu Selection Bar On-Screen OptionsChoices 44 MB, 3 ½ defaultMain Menu Main MenuPrimary/Secondary, Master/Slave Submenu Disabled defaultEnabled default Description Primary/Secondary, Master/Slave SubmenusAdvanced Menu Win2000/.NET DefaultAdvanced Menu Enabled default Disabled default No defaultDOS default Auto Detect defaultO Device Configuration Submenu Device Configuration SubmenuDMA 3 default ECP default DefaultIRQ7 default On Board Device Submenu On Board Device SubmenuPCI Configuration Submenu PCI Configuration SubmenuOption ROM Scan Submenu Choices Enabled defaultChoices Disabled default Server Menu SubmenuConsole Redirection Submenu Console Redirection SubmenuEvent Logging Submenu Enabled default No defaultEvent Logging Submenu Hardware Monitor Submenu Hardware Monitor SubmenuSecurity Menu If no password entered previously FeatureEnabled default User default Security MenuLast State default Power MenuBoot Menu Power MenuDevice Boot MenuBoot Priority System Menu Feature ChoicesSystem Menu Exit Menu Port On Board Connector DesignatorExit Menu Obtaining the Upgrade Utility Upgrading the BiosPreparing for the Upgrade Recording the Current Bios SettingsCreating the Bios Upgrade Diskette Upgrading the BiosRecovering the Bios Changing the Bios Language Sensor Type Hardware MonitoringMonitored Headers and Sensors Intel Server Board SE7500CW2 Product Guide Before You Begin Server Board InstallationSafety Cautions Tools and Supplies NeededSafety and Regulatory Compliance Processor Installation NotesPower Supply Minimum Hardware RequirementsAttaching the Gasket to the I/O Shield Installation ProceduresInstalling the I/O Gasket and Shield Attaching the Label to the I/O Shield Installing the I/O ShieldConfiguring Chassis Standoffs Configuring Chassis StandoffsInstalling Rubber Bumpers Installing Rubber BumpersAttaching the Server Board Installing the Server BoardPlacing the Server Board into the Chassis Installing Memory Installing MemoryInstalling the Retention Brackets Installing the ProcessorsApplying Thermal Grease Attaching the ProcessorAttaching the Heat Sink Installing the Processor Wind TunnelAttaching the Processor Wind Tunnel Assembly Attaching Intake and Exhaust Assemblies Attaching the Heat Sink FanInstalling the Optional Scsi Add-in Card Making Connections to the Server Board Making Connections to the Server BoardIDE Cables Cable RoutingRouting the Floppy Drive Cable Floppy Drive CableMaking Back Panel Connections Finishing UpUpgrading Memory Installing DIMMsProcessors Adding or Replacing a Processor Attaching the Processor Installing the Processor Wind Tunnel OM14477 Removing a Processor Replacing the Backup BatteryVarning Intel Server Board SE7500CW2 Product Guide Initial System Startup Solving ProblemsResetting the System ChecklistAfter the System Has Been Running Correctly Running New Application SoftwareMonitoring Post More Problem Solving ProceduresPreparing the System for Diagnostic Testing Confirming Loading of the Operating System Specific Problems and Corrective ActionsPower Light Does Not Light Verifying Proper Operation of Key System LightsCharacters Are Distorted or Incorrect No Characters Appear on ScreenDiskette Drive Activity Light Does Not Light System Cooling Fans Do Not Rotate ProperlyCannot Connect to a Server Problems with NetworkHard Disk Drive Activity Light Does Not Light CD-ROM Drive Activity Light Does Not LightPCI Installation Tips Problems with Application SoftwareBootable CD-ROM Is Not Detected World Wide Web Telephone Getting HelpIntel Server Board SE7500CW2 Product Guide Jumper Name Configuration JumpersPins What happens at system reset Technical ReferenceLocation Pins DescriptionFront Panel Header Front Panel Header Connection DescriptionsProduct EMC Compliance Product Safety ComplianceRegulatory and Integration Information Product Regulatory ComplianceProduct Certification Markings Electromagnetic Compatibility NoticesProduct Regulatory Compliance Markings Taiwan Declaration of Conformity Europe CE Declaration of ConformityAustralia / New Zealand Korean RRL ComplianceESD IndexPCI
Related manuals
Manual 17 pages 57.58 Kb