Lenovo 6447, 6446, 6445, 6444 manual Installing a memory module

Page 24
Installing a memory module

2.If you are planning to install or remove a microprocessor, memory module, PCI adapter, battery, or other non-hot-swap optional device, turn off the server and all attached devices and disconnect all external cables and power cords (see “Turningoff the server” on page 39).

Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply.

3.Press down on the left and right side latches and pull the server out of the rack enclosure until both slide rails lock.

Note: You can reach the cables on the back of the server when the server is in the locked position.

4.Lift the cover-release latch 1. Lift the cover off the server and set the cover aside.

Attention: For proper cooling and airflow, replace the cover before you turn on the server. Operating the server for extended periods of time (more than 30 minutes) with the cover removed might damage server components.

Installing a memory module

The following notes describe the types of dual inline memory modules (DIMMs) that the server supports and other information that you must consider when installing DIMMs:

vThe server supports up to 12 Fully Buffered DIMM PC2-5300 512 MB, 1 GB, 2 GB, and 4 GB DIMMs, for a maximum of 48 GB of system memory. See http://www.lenovo.com/accessories for a list of memory modules that you can use with the server.

Note: Because some memory is reserved for system operation, the actual usable memory size that is reported by the operating system is less than the total installed size.

vThe server comes with a minimum of two 512 MB DIMMs, installed in slots 1 and 4. When you install additional DIMMs, you must install two identical DIMMS at a time, in the order shown in the following table, to maintain performance.

10ThinkServer RD120 Types 6444, 6445, 6446, and 6447: Installation Guide

Image 24
Contents Installation Guide ThinkServer RD120 Types 6444, 6445, 6446, andPage Installation Guide First Edition October Copyright Lenovo Contents Chapter 3. Server controls, LEDs, and powerChapter 4. Configuring the server Appendix A. Getting help and technical assistance Safety Each caution and danger statement in this document is labeled with a number. This number is used to cross reference an English-language caution or danger statement with translated versions of the caution or danger statement in the Safety Information document Statement DANGER Statement Class 1 Laser Product Laser Klasse Laser Klass Luokan 1 Laserlaite ` Appareil A Laser de Classe≥ 18 kg 39.7 lb ≥ 32 kg 70.5 lb≥ 55 kg 121.2 lb Statement This server is suitable for use on an IT power-distribution system whose maximum phase-to-phase voltage is 240 V under any distribution fault condition Chapter 1. Introduction Hardware and software requirements The Lenovo ThinkServer Documentation DVDFeatures and specifications Notices and statements in this documentTable 1. Features and specifications MicroprocessorMajor components of the server Power backplane Chapter 2. Installing optional devices Installation guidelinesWorking inside the server with the power on System reliability guidelinesHandling static-sensitive devices Removing the coverInstalling a memory module DIMM connectors Pair1 1 and 2 7 and 3 2 and 4 8 and 5 3 and 6 9 and Page Memory mirroring Online-spare memory 1 1, 4, 7, and 2 2, 5, 8, and 3 3, 6, 9, andIn the configuration that you use, install the largest DIMMs first Table 5. Online-spare DIMM configurations, basic schemeInstalling a hard disk drive 3.5-inch drivesInstalling a tape drive 2.5-inch drivesInstalling an additional microprocessor connector Voltage regulator moduleMicroprocessor socket dust cover 4. Remove the microprocessor air baffle Note The microprocessor fits only one way on the socket 8. Install a heat sink on the microprocessor Installing an adapter Low-profile PCI Express adapterPCI riser card Access holes Release tabsInstalling a Remote Supervisor Adapter II SlimLine Hard disk drive cable connector 4Hard disk drive cable connector 0 Battery3. Remove the cover 4. Remove the PCI riser-card assembly Replacing the ServeRAID SAS controller Completing the installation Installing the cover Connecting the cablesFront view Updating the server configuration Rear viewIf you have installed or removed a hard disk drive, see “Usingthe RAID configuration programs” on page 44 for information about reconfiguring the disk arrays Page Chapter 3. Server controls, LEDs, and power Front viewPower-on LED System-error LEDPower-control button Hard disk drive activity LEDRear view Chapter 3. Server controls, LEDs, and powerServer power features Turning on the server Turning off the serverPage Chapter 4. Configuring the server Using the ThinkServer EasyStartup programUser Guide on the ThinkServer Documentation DVD Page Using ThinkServer EasyManage products Using the Configuration/Setup Utility programConfiguring the Gigabit Ethernet controllers Using the RAID configuration programs Using the IBM ServeRAID Configuration Utility programUsing ServeRAID Manager Starting the IBM ServeRAID Configuration Utility programIBM ServeRAID Configuration Utility menu choices Configuring the RAID controllerViewing the configuration 2. Click Express configuration2. Click Custom configuration Using the baseboard management controller BIOS update and configurationLinux configuration Red Hat Enterprise Linux ES 4 configurationLILO configuration If you are using LILO, complete the following steps Original /etc/lilo.conf contents 2. Run the lilo command to store and activate the LILO configuration Original /boot/grub/grub.conf contents SUSE SLES 9.0 configuration Modified /boot/grub/grub.conf contentsOriginal /boot/grub/menu.lst contents Modified /boot/grub/menu.lst contentsb. Add the following line before the first title line c. Append the following text to the first title lineMicrosoft Windows 2003 Standard Edition configuration COM1 and that redirectbaudrate is set toInstalling the OSA SMBridge management utility program 3. Follow the prompts to complete the installation 3. Type mount/mnt/cdromUsing the baseboard management controller utility programs Page Page Chapter 5. Solving problems Diagnostic tools overviewPOST beep codes v Diagnostics DVDOther beep codes POST error codes problem foundPOST Failing device orEasyStartup problems SymptomTable 8. ThinkServer EasyStartup DVD ActionTroubleshooting tables CD-RW/DVD drive problemsGeneral problems Hard disk drive problemsIntermittent problems the Hardware Maintenance ManualUSB keyboard, mouse, or pointing-device problems Memory problems Hardware Maintenance ManualMicroprocessor problems LEDs” in the Hardware Maintenance ManualMonitor problems Page Optional-device problems Power problemsSymptom Serial port problems Software problems Universal Serial Bus USB port problems Video problemsLight path diagnostics Diagnosing problems using light path diagnostics Light path diagnostics LEDsthe User Guide on the ThinkServer Documentation DVD for Description Using the documentation Appendix A. Getting help and technical assistanceBefore you call Calling for service Getting help and information from the World Wide WebUsing other services Purchasing additional servicesLenovo product service Appendix A. Getting help and technical assistancePage Appendix B. Notices Lenovo United States, Inc 1009 Think Place - Building OneMorrisville, NC U.S.A Attention Lenovo Director of Licensing Trademarks Important notesWaste electrical and electronic equipment WEEE notices Appendix B. NoticesBattery return program For the European UnionGerman Ordinance for Work gloss statement Electronic emissions noticesFederal Communications Commission FCC statement For CaliforniaUnited Kingdom telecommunications safety requirement Industry Canada Class A emission compliance statementAvis de conformité à la réglementation dIndustrie Canada Australia and New Zealand Class A statementJapanese Voluntary Control Council for Interference VCCI statement DeutschlandBetriebsmittein Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und ENTaiwanese Class A warning statement Chinese Class A warning statement Korean Class A warning statementIndex A See SAS software problems connectorsIndex Page Page Part Number 46U0862 Printed in USA 1P P/N 46U0862