Setting the Projector Using
SETUP MENU (Main Menu)
▼SETUP MENU
SETUP | ||
| ||
[1]IP Address | [2]Subnet Mask | [3]Default Gateway |
[4]User Name | [5]Password |
|
[7]Projector Name |
| |
[A]Advanced Setup |
| [D]Disconnect All |
[V]View All Setting | [S]Save & Quit | [Q]Quit Unchanged |
setup> |
|
|
|
|
|
[1]IP Address (Factory default setting : 192.168.150.2)
IP address settings. (Page 33)
[2]Subnet Mask (Factory default setting : 255.255.255.0)
Subnet mask settings. (Page 33)
[3]Default Gateway (Factory default setting : Not Used)
Default gateway settings. (Page 33)
[4]User Name (Factory default setting : Not Re- quired)
Setting of user name for security protection. (Page 34)
[5]Password (Factory default setting : Not Required)
Setting of password for security protection. (Page 34)
Baud rate settings for the
34)
[7]Projector Name (Factory default setting : EIP- 4500)
It is possible to assign a projector name. (Page 34)
[A]Advanced Setup
Enters ADVANCED SETUP MENU. (Page 35)
[D]Disconnect All
Disconnect all connections. (Page 35)
[V]View All Setting
Displays all setting values. (Page 31)
Can also be used with ADVANCED SETUP MENU.
[S] Save & Quit
Save set values and quit menu. (Page 32)
[Q]Quit Unchanged
Quit menu without saving setting values. (Page 32)
ADVANCED SETUP MENU
▼ADVANCED SETUP MENU
******************** ADVANCED SETUP MENU ***********************
[1]Auto Logout Time | [2]Data Port |
[5]Network Ping Test |
|
[6]Accept IP Addr(1) | [7]Accept IP Addr(2) [8]Accept IP Addr(3) |
[9]Accept All IP Addr | [0]Search Port |
[!]Restore Default Setting [Q]Return to Main Menu
advanced>
[1]Auto Logout Time (Factory default setting : 5 min- utes)
Setting of time until automatic disconnection of net- work connection. (Page 35)
[2]Data Port (Factory default setting : 10002)
Setting the TCP port number used when exchang- ing data. (Page 35)
[5]Network Ping Test
It is possible to confirm that a network connection between the projector and a computer etc. is work- ing normally. (Page 36)
[6]Accept IP Addr(1) [7]Accept IP Addr(2) [8]Accept IP Addr(3)
[9]Accept All IP Addr (Factory default setting : Ac- cept All)
For improved security, it is possible to set up to three IP addresses allowing connection to the projector. Set IP addresses can be cancelled using [9] Accept All IP Addr. (Page 36)
[0] Search Port (Factory default setting : 9300)
Setting the port number used when searching for the projector. (Page 37)
[!]Restore Default Setting
Restores all setting values that can be set using the
menu to the default state. (Page 37)
[Q]Return to Main Menu
Return to the main SETUP MENU. (Page 37)
30