Xerox 2750 manual Afnor

Page 40

34

8.5 x 11 BkB 1.0

No

Bookfold Style B, 7 ½” panels, 1" binding margin, Z crossfold

35

8.5 x 11 BkB Z 1.25

No

Bookfold Style B, 7¼" panels, 1¼" binding margin, Z crossfold

36

8.5 x 11 BkB Z 1.50

No

Bookfold Style B, 7" panels, 1½" binding margin, Z crossfold

37

8.5 x 11 BkB Z 1.75

No

Bookfold Style B, 6¾" panels, 1¾" binding margin, Z crossfold

38

8.5 x 11 BkB Z 2.00

No

Bookfold Style B, 6½" panels, 2" binding margin, Z crossfold

39

 

 

Reserved

40

 

 

Reserved

41

210 x 297 PORT C

Yes

210 x 297mm portrait packet with C style crossfold

42

210 x 297 LAND C

Yes

210 x 297mm landscape packet with C style crossfold

43

DIN 824 TYPE B

No

Bookfold Style F, 190mm panels, 0mm binding margin, tab, Z crossfold, 297 mm, title

 

 

 

block leading

44

DIN 824 TYPE C

Yes

Endless fold style 210mm panels, Z crossfold, 297mm, title block leading

45

 

 

Reserved

46

210 x 297 BkF Z 0mm

No

Bookfold Style F, 210mm panels, 0mm binding margin, Z crossfold, title block leading

47

DIN 824 TYPE A

Yes

Bookfold Style F, 190mm panels, 20mm binding margin, Z crossfold

48

210 x 297 BkF Z 30mm

No

Bookfold Style F, 180mm panels, 30mm binding margin, Z crossfold

49

210 x 297 BkF Z 40mm

No

Bookfold Style F, 170mm panels, 40mm binding margin, Z crossfold

50

7080/85 FOLDS –

No

Emulation of 7080/7085 Z folds for DIN sizes, 190mm panels, 20mm binding margin, Z

 

210 x 298mm

 

crossfold

51

AFNOR

No

AFNOR fold program

52

 

 

Reserved

53

ERICSSON

No

Special fold program to Ericsson specifications, title block leading

54

 

 

Reserved

55

190 FANFOLD

Yes

190mm panels, accordion fold only

56

210 FANFOLD

Yes

210mm panels, accordion fold only

57

297 FANFOLD

Yes

297mm panels, accordion fold only

58

INV DIN 210 x 297

No

210 x 297mm portrait packet for Inverse DIN drawing format, Z crossfold

59

 

 

Reserved

60

ANSI-ARCH MIX

No

Special mixed fold table

61

INV AFNOR

No

210 x 297mm portrait packet for Inverse AFNOR drawing format

62

7.5 x 10 LAND C

No

7½" x 10" portrait packet, C crossfold

63

 

 

Reserved

64

8.5 x 11 LAND C

No

8½" x 11" landscape packet, special for AZ Public Service

65

9 x 6 / 9 x 12 MIX

No

Special 9" fan fold with either 6" or 12" crossfold depending on roll size, for insertion in

 

 

 

mailers, etc.

66

 

 

Reserved

67

210 x 297 BkF Z 0mm

No

Bookfold Style F, 210mm panels, 0mm binding margin, Z crossfold, title block trailing

 

#2

 

 

68

DIN 824 TYPE A #2

No

Bookfold Style F, 190mm panels, 20mm binding margin, Z crossfold, title block trailing

69

ERICSSON #2

No

Special fold program to Ericsson specifications, title block trailing

70

INV DIN 20mm

No

Bookfold fold program for Inverse DIN drawing format, 20mm binding margin, title block

 

 

 

leading

71

INV DIN 190 x 297

No

190 x 297mm portrait packet for Inverse DIN drawing format

2750 op#4 R3.doc 10-02

Page 4-6

Image 40
Contents PRINTFOLD Synergix Fold System Engineering Document Folder Synergix Fold System General informationMain components of the Model 2750 Folder Power entry module / counter / communications port Operator’s control panelMain control panel Instant service access BridgeStacker/Handfeed Automatic document diversionTower in normal folding and bypass modes Manual feed slotAccordion folding overview Standard accordion fold packetType F bookfold packet Crossfolding overview Folds handle easier than Z-foldsSEL = standard feed direction Key facts about fold programsLEL = non-standard feed direction Width sensors at input end of bridge Main features of the 2750 folding system Options availablePower entry panel After installationModel 2750 Folder operator’s side Operator’s controls ½ x 11 C-folded packet, landscape style12 Z-folded packet, portrait style BkaZ ½ x 11 book-folded packet Z fold onlyFold Selection Host controller Start-upReset procedure Fold Selection StandaloneOn-line programs Hand feed programsManual document feeding Rear of diverter tower, showing stacker/off-line componentsTo begin hand feeding Hand feeding a documentExiting Handfeed Mode Jam conditions Clearing a jamBridge and Bridge Exit If the document is visibleRaising the bridge lid Unlocking the bridgeTower Access to the towerRaising the bridge Use the jog feature … Accordion FolderAccordion folder lid in raised position Opening the upper clam shellRaising the drum faceplate shutter Using the crank handle to rotate the drumEjector springs on crank handle Crossfolder latches CrossfolderUpper section of the crossfolder in raised position Crossfold Transfer Crossfold Pocket and Crossfold ExitCrossfolder rear panel Unhitching the accordion and cross folderCrank handle engaged in crossfold roll Interlock OpenCrossfold pocket System Error Accordion Folder Initial phase of the folding programIn-feed and accordion folding components Drum reversal develops a loop Panel measuring phaseCompletion of the first fold Starting the second fold Accordion fold compensating panelsCrossfolder Document inversionFirst crossfold action Single crossfold mode Double crossfold modeOperator’s control panel System MenuPasswords Communications modeJog functions Parameter viewing and modificationAccessible only to the Key Operator and technician Device testActivity counters Recent errorsSheets 1s 3 0 5 721p Synergix Fold System 40 & XES 2750 Series fold tables DescriptionAfnor Fold Banks Peco Fold MIXFold Bank 1 common European sizes Folder Error Messages Message Definition Location or type of error