Xerox 2750 manual Fold Bank 1 common European sizes

Page 42

FOLD BANK 1 (common European sizes)

Position

Fold

Display

Description

 

Table

 

 

1

0

STACK

No fold, flat sheet stack on top of folder cabinet

2

47

DIN 824 TYPE A

Bookfold Style 1 (F = Favors Front), 190mm panels, 20mm binding margin, Z

 

 

 

crossfold

3

43

DIN 824 TYPE B

Bookfold Style 1 (F = Favors Front), 190mm panels, 0mm binding margin, tab, Z

 

 

 

crossfold 297mm

4

44

DIN 824 TYPE C

Endless fold style 210mm panels, Z crossfold 297mm

5

46

210 x 297 BkF Z

Bookfold Style 1 (F = Favors Front), 210mm panels, 0mm binding margin, Z

 

 

0mm

crossfold

6

53

ERICSSON

Special fold program to Ericsson specification

7

56

210 FANFOLD

210mm panels, accordion fold only

8

57

297 FANFOLD

297mm panels, accordion fold only

FOLD BANK 2 (special French/European sizes)

Position

Fold

Display

Description

 

Table

 

 

1

0

STACK

No fold, flat sheet stack on top of folder cabinet

2

73

DIN 824 TYPE C #2

Endless fold style 210mm panels, Z crossfold 297mm, title block trailing

3

58

INV DIN 210 x 297

Special AFNOR LIKE fold program, title block leading

4

51

AFNOR

Special AFNOR fold program

5

68

DIN 824 TYPE A #2

Bookfold Style 1 (F = Favors Front), 190mm panels, 20mm binding margin, Z

 

 

 

crossfold, title block trailing

6

72

DIN 824 TYPE B #2

Bookfold Style 1 (F = Favors Front), 190mm panels, 0mm binding margin, tab, Z

 

 

 

crossfold 297 mm, title block trailing

7

56

210 FANFOLD

210mm panels, accordion fold only

8

57

297 FANFOLD

297mm panels, accordion fold only

9

69

ERICSSON #2

Special fold program to Ericsson specification, title block trailing

10

67

210 x 297 BkF Z

Bookfold Style 1 (F = Favors Front), 210mm panels, 0mm binding margin, Z

 

 

0mm #2

crossfold, title block trailing

11

48

210 x 297 BkF Z

Bookfold Style 1 (F = Favors Front), 180mm panels, 30mm binding margin, Z

 

 

30mm

crossfold

12

55

190 FANFOLD

190mm panels, accordion fold only

13

41

210 x 297 PORT C

210 x 297mm portrait packet with C style crossfold

14

42

210 x 297 LAND C

210 x 297mm landscape packet with C style crossfold

15

49

210 x 297 BkF Z

Bookfold Style 1 (F = Favors Front), 170mm panels, 40mm binding margin, Z

 

 

40mm

crossfold

16

70

INV DIN 20mm

Special AFNOR LIKE Bookfold fold program, 20mm binding margin, title block

 

 

 

leading

17

71

INV DIN 190x 297

Special AFNOR LIKE fold program

18

61

INV AFNOR

210 X 297 mm packet, inverse AFNOR drawing format

2750 op#4 R3.doc 10-02

Page 4-8

Image 42
Contents PRINTFOLD Synergix Fold System Engineering Document Folder General information Synergix Fold SystemMain components of the Model 2750 Folder Power entry module / counter / communications port Operator’s control panelMain control panel Stacker/Handfeed Instant service accessBridge Automatic document diversionTower in normal folding and bypass modes Manual feed slotAccordion folding overview Standard accordion fold packetType F bookfold packet Crossfolding overview Folds handle easier than Z-foldsKey facts about fold programs SEL = standard feed directionLEL = non-standard feed direction Width sensors at input end of bridge Main features of the 2750 folding system Options availableAfter installation Power entry panelModel 2750 Folder operator’s side 12 Z-folded packet, portrait style Operator’s controls½ x 11 C-folded packet, landscape style BkaZ ½ x 11 book-folded packet Z fold onlyFold Selection Host controller Start-upOn-line programs Reset procedureFold Selection Standalone Hand feed programsManual document feeding Rear of diverter tower, showing stacker/off-line componentsTo begin hand feeding Hand feeding a documentExiting Handfeed Mode Jam conditions Clearing a jamRaising the bridge lid Bridge and Bridge ExitIf the document is visible Unlocking the bridgeAccess to the tower TowerRaising the bridge Accordion folder lid in raised position Use the jog feature …Accordion Folder Opening the upper clam shellUsing the crank handle to rotate the drum Raising the drum faceplate shutterEjector springs on crank handle Crossfolder Crossfolder latchesUpper section of the crossfolder in raised position Crossfolder rear panel Crossfold TransferCrossfold Pocket and Crossfold Exit Unhitching the accordion and cross folderInterlock Open Crank handle engaged in crossfold rollCrossfold pocket System Error Initial phase of the folding program Accordion FolderIn-feed and accordion folding components Panel measuring phase Drum reversal develops a loopCompletion of the first fold Starting the second fold Accordion fold compensating panelsDocument inversion CrossfolderFirst crossfold action Single crossfold mode Double crossfold modeOperator’s control panel System MenuJog functions PasswordsCommunications mode Parameter viewing and modificationAccessible only to the Key Operator and technician Device testRecent errors Activity countersSheets 1s 3 0 5 721p Synergix Fold System 40 & XES 2750 Series fold tables DescriptionAfnor Fold Banks Peco Fold MIXFold Bank 1 common European sizes Folder Error Messages Message Definition Location or type of error