Xerox 2750 manual Recent errors, Activity counters, Sheets 1s 3 0 5

Page 38

To edit the operator’s program list, select Assign Folds from the SYSTEM MENU. The control panel displays:

Fold Menu: #2

Fold Table: Number

Description

1: Change 4: Quit

NOTE: “Table” = Program number in the folder firmware, see Section 9.

The #2 menu selection is the first one available for editing because the first selection is always STACK, which cannot be changed. To change or delete the selection press 1. The control panel displays:

1:Set By Fold Table #

2:Choose from List

3:Remove from Menu

4:Quit

If you do not know the “table” (fold program), or do not have Section 9 available, press the 2 button to enter the list, then scroll through to select (press 1 to “Add”). To delete the current fold program from the Fold Bank, press the 3 button (this does not erase the program from the firmware). Press 4 to return to the previous display.

The maximum number of fold programs that can be included in the operator’s program list (NVRAM) is 20.

Recent errors

Displays the last 21 fault conditions, and the number of prints successfully passed between events. Event #1 is the most recent. Example:

Event #

Error code

Quantity

1.

0042 (occurred after)

1957 (prints passed since previous event)

2.

0010

4350

3.

F142

5128

Activity counters

1.Mechanical counter

The mechanical (electromagnetic) counter situated below the power switch records linear feet.

2.Software sheet counter

In addition to linear feet displayed by the mechanical counter, the folder also keeps track in software of the number of sheets ("clicks") processed. This is displayed in the Parameters menu as follows (two lines due to display limitations):

SHEETS (Ks) 1 4 8 7 = 1,487,000

SHEETS (1s) 3 0 5 305

Total 1,487,305

2750 op#4 R3.doc 10-02

Page 4-4

Image 38
Contents PRINTFOLD Synergix Fold System Engineering Document Folder Main components of the Model 2750 Folder General informationSynergix Fold System Power entry module / counter / communications port Operator’s control panelMain control panel Stacker/Handfeed Instant service accessBridge Automatic document diversionTower in normal folding and bypass modes Manual feed slotAccordion folding overview Standard accordion fold packetType F bookfold packet Crossfolding overview Folds handle easier than Z-foldsLEL = non-standard feed direction Key facts about fold programsSEL = standard feed direction Width sensors at input end of bridge Main features of the 2750 folding system Options availableModel 2750 Folder operator’s side After installationPower entry panel 12 Z-folded packet, portrait style Operator’s controls½ x 11 C-folded packet, landscape style BkaZ ½ x 11 book-folded packet Z fold onlyFold Selection Host controller Start-upOn-line programs Reset procedureFold Selection Standalone Hand feed programsManual document feeding Rear of diverter tower, showing stacker/off-line componentsTo begin hand feeding Hand feeding a documentExiting Handfeed Mode Jam conditions Clearing a jamRaising the bridge lid Bridge and Bridge ExitIf the document is visible Unlocking the bridgeRaising the bridge Access to the towerTower Accordion folder lid in raised position Use the jog feature …Accordion Folder Opening the upper clam shellEjector springs on crank handle Using the crank handle to rotate the drumRaising the drum faceplate shutter Upper section of the crossfolder in raised position CrossfolderCrossfolder latches Crossfolder rear panel Crossfold TransferCrossfold Pocket and Crossfold Exit Unhitching the accordion and cross folderCrossfold pocket Interlock OpenCrank handle engaged in crossfold roll System Error In-feed and accordion folding components Initial phase of the folding programAccordion Folder Completion of the first fold Panel measuring phaseDrum reversal develops a loop Starting the second fold Accordion fold compensating panelsFirst crossfold action Document inversionCrossfolder Single crossfold mode Double crossfold modeOperator’s control panel System MenuJog functions PasswordsCommunications mode Parameter viewing and modificationAccessible only to the Key Operator and technician Device testSheets 1s 3 0 5 Recent errorsActivity counters 721p Synergix Fold System 40 & XES 2750 Series fold tables DescriptionAfnor Fold Banks Peco Fold MIXFold Bank 1 common European sizes Folder Error Messages Message Definition Location or type of error