Cisco Systems 7507 quick start Install Power Supplies in the Router

Page 13

Install the Hardware

Install Power Supplies in the Router

tive

 

 

 

 

allation

DC

 

 

FAIL

 

 

AC

ew

POWER

 

I

0

This procedure applies to AC-input and DC-input power supplies, with differences clearly noted. Do not mix AC-input and DC-input power supplies in the same chassis. Install the first power supply in the lower power supply bay and the second, if any, in the upper bay. In systems with dual power supplies and

separate available power sources, connect each power supply to separate input lines—the second power source will likely be available during a failure.

Step 1 For AC-input power supplies, confirm that the power on the power supply is off.

For DC-input power supplies, turn off the circuit breaker to which you will connect power, and tape the breaker switch to the off position.

Step 2 Hold the power supply by the handle and place your other hand underneath it.

Caution Use two hands to remove and install power supplies.

Step 3 Place the power supply inside the bay, and align it to go straight into the bay.

Step 4 Push the power supply back into the bay until its front panel is flush with the chassis rear panel.

11

Image 13
Contents Quick Start Guide Page Packing List Install the HardwareFor rack-mounting optional Prepare to Install the RouterInstall the Router Grommets Rack-Mount the Router OptionalMount Brackets to the Rack Posts Step Secure the SpacersAttach the Chassis Ears Mount the Chassis in the Rack Remove the Chassis Foot Install Interface Processors, Fillers, VIPs, or RSPs Install Power Supplies in the Router Page On terminal block cover Install the DC-Input Power SupplyPage Connect the RSP Connect the Console and the Auxiliary Y-Cables Start and Configure the System Start a Basic Configuration Perform a Basic Configuration Using Setup At the # prompt, enter the copy Configure an Ethernet Interface Hostname# copy running-config startup-config Perform a Basic Configuration Using Configuration Mode Flash Memory Cards Install Field Replaceable Units FRUsPage Copy Files to Flash Memory Format a Flash Memory CardEnable Booting from Flash Memory Make a Flash Memory Card Image BootablePrepare to Remove and Install an RSP Stop Check the RSP Installation Check the Interface Processor or VIP Installation Copy the Configuration File for an RSP Router# copy startup-config tftp Writing Router-confg Retrieve the Configuration File for RSPs Systemrunning-config Nvramstartup-config command Remove and Install Port Adapters Page Remove and Replace the Power Supply H2530 Headquarters