Cabletron Systems manual 1 T1 Service Physical Configuration

Page 36

Chapter 3: Local Management for T1 Service

3.3.1T1 Service Physical Configuration

Begin the T1 configuration by accessing the WAN Physical Configuration screen through Local Management (Figure 3-1). Access the WAN Physical Configuration screen from the WAN SETUP menu item in the host platform.

Proceed with the following steps:

1.Use the arrow keys to highlight the WPIM X field at the bottom of the screen. Press the SPACE bar to select the number of the WPIM to be configured, then press ENTER.

2.Use the arrow keys to highlight MgrType. Select PPP.

NOTE

When changing from one protocol to another on a WPIM-T1/DDS that has been operational, save NONE as the protocol before changing to another protocol.

3.Use the arrow keys to highlight Timeslot View. Press the SPACE bar to select New, then press ENTER. The cursor moves to Timeslot #1 of the Timeslot Configuration Table.

4.Insert an interface number (refer to NOTE below) into every timeslot as needed. Type the number, press ENTER, then use the arrow keys to highlight the next timeslot field. Exit this field by using the arrow keys. The cursor automatically moves to the T1 Line Coding field.

NOTE

The value assigned to the timeslots is the interface being used for WAN communication. The next available interface is displayed on the WAN Physical Configuration screen in the Next IF field (seeFigure 3-1). The Next IF number shown must be used to add a new interface. The Next IF will increment as interfaces are added. The previously entered interfaces can be modified by entering the interface number.

The following four steps are based on information supplied by the service provider. Consult the service provider for the correct settings.

5.Use the arrow keys to highlight T1 Line Coding. Press the SPACE bar to select B8ZS or AMI, then press ENTER.

6.Use the arrow keys to highlight T1 Frame Type. Press the SPACE bar to select ESF or D4, then press ENTER.

3-12

WPIM-T1/DDS User’s Guide

Image 36
Contents WPIM-T1/DDS User’s Guide Page WPIM-T1/DDS User’s Guide Industry Canada Notice Cabletron SYSTEMS, INC. Program License Agreement United States Government Restricted Rights Declaration of Conformity WPIM-T1/DDS User’s Guide Contents Viii WPIM-T1/DDS User’s Guide Using this Manual IntroductionStructure of this Guide Related Manuals Document Conventions Following conventions are used throughout this documentGetting Help Your email addressChapter Overview WPIM-T1/DDS Features Firmware RevisionImportant Notice WAN Protocols MIB SupportOverview WPIM-T1/DDS User’s Guide Chapter Setup and Installation Installing the WPIM-T1/DDSUnpacking the WPIM-T1/DDS Pre-Installation Installing the WPIM-T1/DDSPost-Installation Installing the WPIM-T1/DDSChoosing T1 or DDS Mode LEDsRequired Operations WAN Configuration Connecting the WAN Cable to the WPIM-T1/DDS WAN Connection to the WPIM-T1/DDSChapter Local Management for T1 Service WAN Physical Configuration Screen Wpim #WAN Physical Configuration Screen Fields Wpim Line Configuration Fields Saves the chosen configurationWpim Timeslot Configuration Table Sample Timeslot Configuration WAN Interface Configuration Screen ANSI94WAN Interface Configuration Screen Fields Frame Relay as the Protocol ManagerPPP as the Protocol Manager WAN Interface Configuration Screen PPPCommand and Interface Table Fields Full T1 Configuration Using PPP Telco Configuration Information1 T1 Service Physical Configuration 2 T1 Interface Configuration Fractional T1 Configuration Using PPP Fractional T1 Configuration1 T1 Physical Configuration Proceed to the .4.2 to continue configuration Frame Relay Configuration Frame Relay ConfigurationFrame Relay Physical Configuration Frame Relay Configuration Frame Relay Interface Configuration Frame Relay Configuration WPIM-T1/DDS User’s Guide Chapter Local Management for DDS Service Local Management for DDS Service Displays configuration information for two different WPIMs Not used for the WPIM-T1/DDS Invalid Refer to -2for the following parameters displayed for FR Refer to -3for the following parameters displayed for PPP Command and Interface Table Fields DDS Service Configuration DDS Service Physical ConfigurationDDS Service Interface Configuration EnterDDS Service Configuration WPIM-T1/DDS User’s Guide Appendix a Specifications Physical PropertiesEnvironmental Requirements Regulatory ComplianceT1 Interface Cabling Cable Assemblies and PinoutsT1 Interface Cabling PIN Signal DDS Port AssignmentAppendix B FCC Part 68 USER’S InformationAppendix B FCC Part 68 User’s Information Being duly sworn, state My commission expires