Cabletron Systems T1 Appendix a Specifications, Physical Properties, Environmental Requirements

Page 59

APPENDIX A

SPECIFICATIONS

This appendix provides operating specifications for the Cabletron Systems WPIM-T1/DDS. Cabletron Systems reserves the right to change these specifications at any time without notice.

A.1 PHYSICAL PROPERTIES

Dimensions

1.94 H x 6.2 W x 15.06

D (cm)

.762 H x 2.44 W x 5.93

D (in)

 

 

 

 

Weight

113.6 g (4 ounces)

 

 

 

 

MTBF (Predicted)

200,000 hours

 

 

 

 

A.2 ENVIRONMENTAL REQUIREMENTS

Operating Temperature

5°C to 40°C (41°F to 104°F)

 

 

Storage Temperature

-30°C to 90°C (-22°F to °F)

 

 

Relative Humidity

5% to 95% (non-condensing)

 

 

A.3 REGULATORY COMPLIANCE

This equipment meets the following safety and electromagnetic compatibility (EMC) requirements:

Safety

UL 1950, CSA C22.2 No. 950,

EN 60950, IEC 950, and 73/23/EEC

 

 

 

Electromagnetic Compatibility

FCC Part 15, EN 55022, VCCI V-3,

CSA C108.8, EN 50082-1,

(EMC)

AS/NZS 3548, 89/336/EEC

 

 

 

Telecommunications

FCC CFR47 Part 68, CS-03

 

 

WPIM-T1/DDS User’s Guide

A-1

Image 59
Contents WPIM-T1/DDS User’s Guide Page WPIM-T1/DDS User’s Guide Industry Canada Notice Cabletron SYSTEMS, INC. Program License Agreement United States Government Restricted Rights Declaration of Conformity WPIM-T1/DDS User’s Guide Contents Viii WPIM-T1/DDS User’s Guide Structure of this Guide Using this ManualIntroduction Related Manuals Following conventions are used throughout this document Document ConventionsYour email address Getting HelpChapter Overview Important Notice WPIM-T1/DDS FeaturesFirmware Revision MIB Support WAN ProtocolsOverview WPIM-T1/DDS User’s Guide Unpacking the WPIM-T1/DDS Chapter Setup and InstallationInstalling the WPIM-T1/DDS Installing the WPIM-T1/DDS Pre-InstallationInstalling the WPIM-T1/DDS Post-InstallationRequired Operations Choosing T1 or DDS ModeLEDs WAN Configuration WAN Connection to the WPIM-T1/DDS Connecting the WAN Cable to the WPIM-T1/DDSChapter Local Management for T1 Service Wpim # WAN Physical Configuration ScreenWAN Physical Configuration Screen Fields Saves the chosen configuration Wpim Line Configuration FieldsWpim Timeslot Configuration Table Sample Timeslot Configuration ANSI94 WAN Interface Configuration ScreenFrame Relay as the Protocol Manager WAN Interface Configuration Screen FieldsWAN Interface Configuration Screen PPP PPP as the Protocol ManagerCommand and Interface Table Fields Telco Configuration Information Full T1 Configuration Using PPP1 T1 Service Physical Configuration 2 T1 Interface Configuration Fractional T1 Configuration Fractional T1 Configuration Using PPP1 T1 Physical Configuration Proceed to the .4.2 to continue configuration Frame Relay Configuration Frame Relay ConfigurationFrame Relay Physical Configuration Frame Relay Configuration Frame Relay Interface Configuration Frame Relay Configuration WPIM-T1/DDS User’s Guide Chapter Local Management for DDS Service Local Management for DDS Service Displays configuration information for two different WPIMs Not used for the WPIM-T1/DDS Invalid Refer to -2for the following parameters displayed for FR Refer to -3for the following parameters displayed for PPP Command and Interface Table Fields DDS Service Physical Configuration DDS Service ConfigurationEnter DDS Service Interface ConfigurationDDS Service Configuration WPIM-T1/DDS User’s Guide Regulatory Compliance Appendix a SpecificationsPhysical Properties Environmental RequirementsCable Assemblies and Pinouts T1 Interface CablingT1 Interface Cabling DDS Port Assignment PIN SignalFCC Part 68 USER’S Information Appendix BAppendix B FCC Part 68 User’s Information Being duly sworn, state My commission expires