Cabletron Systems T1 manual WAN Physical Configuration Screen Fields

Page 27

The WAN Physical Configuration Screen

3.1.1WAN Physical Configuration Screen Fields

The following sections describe WAN Physical Configuration screen fields and provide instructions for setting them. The WAN Physical Configuration screen lets you configure the WPIM or “Physical Interface.”

NOTE

The Type field displays either T1 or DDS, depending on the mode selected using Network Tools.

To select the WPIM you wish to configure, proceed as follows:

1.Use the arrow keys to highlight the WPIM X command field at the bottom of the screen.

2.Use the SPACE bar to select the appropriate WPIM, then press ENTER. The WAN Configuration screen automatically displays unique configuration fields for each WPIM as shown in Figure 3-1.

The WAN Physical Configuration screen displays the following information for each WPIM:

WPIM 1-2(Read-Only)

Displays configuration information for up to two different WPIMs.

Type (Read-Only)

Displays the type of WPIM installed. For the WPIM-T1/DDS, the Type field displays the service selected. When T1 service is selected, T1 is displayed. When DDS service is selected, DDS is displayed.

WPIM # (Read-Only)

Displays the number of the slot in which the WPIM resides.

Mgr Type (Selectable)

Used to select the type of protocol manager. For the T1 mode of the WPIM-T1/DDS, the available options are PPP, FR PtoMP, FR PtoP, HDLC and NONE. The field defaults to NONE.

Max VCs (Modifiable)

Displays the maximum number of virtual circuits (interfaces) available to be configured. The default number displayed depends on the Protocol Manager chosen.

Next IF (Read-Only)

Displays the next interface available to be used.

WPIM-T1/DDS User’s Guide

3-3

Image 27
Contents WPIM-T1/DDS User’s Guide Page WPIM-T1/DDS User’s Guide Industry Canada Notice Cabletron SYSTEMS, INC. Program License Agreement United States Government Restricted Rights Declaration of Conformity WPIM-T1/DDS User’s Guide Contents Viii WPIM-T1/DDS User’s Guide Using this Manual IntroductionStructure of this Guide Related Manuals Following conventions are used throughout this document Document ConventionsYour email address Getting HelpChapter Overview WPIM-T1/DDS Features Firmware RevisionImportant Notice MIB Support WAN ProtocolsOverview WPIM-T1/DDS User’s Guide Chapter Setup and Installation Installing the WPIM-T1/DDSUnpacking the WPIM-T1/DDS Installing the WPIM-T1/DDS Pre-InstallationInstalling the WPIM-T1/DDS Post-InstallationChoosing T1 or DDS Mode LEDsRequired Operations WAN Configuration WAN Connection to the WPIM-T1/DDS Connecting the WAN Cable to the WPIM-T1/DDSChapter Local Management for T1 Service Wpim # WAN Physical Configuration ScreenWAN Physical Configuration Screen Fields Saves the chosen configuration Wpim Line Configuration FieldsWpim Timeslot Configuration Table Sample Timeslot Configuration ANSI94 WAN Interface Configuration ScreenFrame Relay as the Protocol Manager WAN Interface Configuration Screen FieldsWAN Interface Configuration Screen PPP PPP as the Protocol ManagerCommand and Interface Table Fields Telco Configuration Information Full T1 Configuration Using PPP1 T1 Service Physical Configuration 2 T1 Interface Configuration Fractional T1 Configuration Fractional T1 Configuration Using PPP1 T1 Physical Configuration Proceed to the .4.2 to continue configuration Frame Relay Configuration Frame Relay ConfigurationFrame Relay Physical Configuration Frame Relay Configuration Frame Relay Interface Configuration Frame Relay Configuration WPIM-T1/DDS User’s Guide Chapter Local Management for DDS Service Local Management for DDS Service Displays configuration information for two different WPIMs Not used for the WPIM-T1/DDS Invalid Refer to -2for the following parameters displayed for FR Refer to -3for the following parameters displayed for PPP Command and Interface Table Fields DDS Service Physical Configuration DDS Service ConfigurationEnter DDS Service Interface ConfigurationDDS Service Configuration WPIM-T1/DDS User’s Guide Regulatory Compliance Appendix a SpecificationsPhysical Properties Environmental RequirementsCable Assemblies and Pinouts T1 Interface CablingT1 Interface Cabling DDS Port Assignment PIN SignalFCC Part 68 USER’S Information Appendix BAppendix B FCC Part 68 User’s Information Being duly sworn, state My commission expires