Extron electronic ISM 182 manual Programmer’s Guide, cont’d

Page 50

Programmer’s Guide, cont’d

1Blu X19

The blue-only mode has been turned on or off for one or both outputs from the front panel. X19 is the on/off status for the either or both outputs. The leading “1” is meaningless.

1Fil X19

The edge enhancement mode has been turned on or off for one or both outputs from the front panel. X19 is the on/off status for the either or both outputs. The leading “1” is meaningless.

RGB delay

X2 Dly X20

A front panel RGB delay adjustment has occurred. X2 is output number and the delay value, in 0.01 second steps. X20 can be as much as 50 = 5.0 seconds.

X20

is

Test pattern

Tst X19 * X21

A test pattern has been turned on or off for one or both outputs from the front panel. X19 is the on/off status for the two outputs and X21 is the test pattern selected.

Audio gain and attenuation

X1 Aud X22

A front panel audio input level adjustment has occurred. X22 is the audio gain or attenuation level.

X1

is input number and

Video and audio mute

X2 Vmt X3

A front panel video mute operation has occurred. X2 is output number and the mute status: 0 =off (video not muted, 1 = on (video muted).

X3

is

X2 Amt X3

A front panel audio mute operation has occurred. X2 is output number and the mute status: 0 =off (audio not muted, 1 = on (audio muted).

X3

is

PAL film mode

X1 Flm X3

The PAL film mode has been selected or deselected from the front panel for the selected input. X1 is input number and X3 is the on/off status for PAL film mode.

Automated adjustments

Img X3

The Auto Image feature has been turned on or off from the front panel for all tie creations. X3 is the on/off status.

Aut X3

The auto presets feature has been turned on or off from the front panel for all tie creations. X3 is the on/off status.

4-6 Integration Scaling Matrix Switcher • Programmer’s Guide

Image 50
Contents Integration Scaling Matrix Switchers ISM 482 & ISMSicherheitsanleitungen Deutsch Safety Instructions EnglishConsignes de Sécurité Français Instrucciones de seguridad EspañolQuick Start Integration Scaling Matrix Switcher QS-1Quick Start Integration Scaling Matrix Switcher, cont’d QS-2Table of Contents Table of Contents, cont’d Integration Scaling Matrix Switcher Table of Contents Iii Iv Integration Scaling Matrix Switcher Table of Contents One Introductiontroduction, cont’d About the SwitcherIntegration Scaling Matrix Switcher Introduction About this ManualExtron ISM Features Introduction, cont’dIntegration Scaling Matrix Switcher Introduction Introduction, cont’d Two Tabletop placement Installationstallation, cont’dMounting the Switcher Integration Scaling Matrix Switcher InstallationCabling and Rear Panel Views Input connectionsInstallation, cont’d Captive screw connector wiring for inputsOutput connections BNC output connections for Rgbhv and Rgbs videoChoosing a network cable Cabling and RJ-45 connector wiringEthernet connection Wiring the network cable RJ-45 connector pinout tablesConfiguration RS-232 connectionThree Operationeration, cont’d Front Panel Controls and IndicatorsIntegration Scaling Matrix Switcher Operation Video/Audio selection button and LEDsFront panel input label window Outputs buttons and LEDsInput buttons, LEDs, and label window Black/Mute button and LEDs Picture adjustment buttonsOperation, cont’d Menu control buttons Adjustment knobsLCD display Power Front Panel OperationsMenu system overview Extron Electronics ISM 60-425-01 VersionVideo & Audio Configuration menu Input Configuration submenuOutput Configuration menu Output Resolution submenuResolution 50 Hz 56 Hz 60 Hz 75 Hz 85 Hz Lock at 50/60 Hz Sync Type and Polarity submenuAdvanced Configuration menu Video & AudioTest Pattern submenu Blue Only Mode and Edge Smoothing submenuRGB Delay submenu Blanking submenuPAL Film Mode submenu Enhanced Mode submenuPixel Phase submenu Reset submenuUser Presets menu Save Preset submenuErase Preset submenu Exit menuPicture adjustments 13 Picture adjustments flowchartFront panel security lockout executive mode 14 Front panel security lockout flowchartOptimizing the Video IP informationSetting up a DVD source Controls to position the imageGeneral checks TroubleshootingOptimizing the Audio Specific problems Problem CauseOperation, cont’d Four Ethernet Link Integration Scaling Matrix Switcher Programmer’s GuideRS-232 Link Symbols Default addressTies creation Switcher-Initiated MessagesPower-up Input and output video typeX2 Col Programmer’s Guide, cont’d Using the command/response table Host-to-Switcher InstructionsSwitcher error responses Command Ascii Command Response Additional description Horizontal size BrightnessContrast Vertical sizeHorizontal detail filter RGB and component video inputs Pixel phaseBottom blanking Vertical detail filter RGB and component video inputsFreeze User presetsAuto Memories Test patternInformation requests Executive modeVerbose mode Command/response table for IP SIS commands ResetsScaler settings Command/response table for special function SIS commandsDelay times Blue screen Enhanced modePAL film mode Edge smoothingAdditional description Command Hex Command ResponseMemory backup Five Integration Scaling Matrix Switcher Switcher Software Installing the softwareEthernet protocol settings Control Software for WindowsUsing the control program If you selected a comm port, proceed to stepSwitcher Software, cont’d Windows Control program windowUsing the help program Button-Label GeneratorInstalling the software Using the softwareSix Load the Startup Control Integration Scaling Matrix Switcher Ethernet OperationEthernetOperation,cont’d Control Control Change the RGB delayEthernet Operation, cont’d Create a tieOutput a test pattern Executive modeFreeze the output Preview the scan rateSystem Configuration System ConfigurationISM IP Address field Administration fieldsISM IP Settings fields ISM Name fieldFile Management File ManagementInput configuration I/O ConfigurationOutput resolution, rate, sync format, and polarity Output resolution Output rateOutput format Output polarityAAppendix a Integration Scaling Matrix Switcher Ethernet Connection Ethernet Connection, cont’dPing to determine the switcher’s IP address Ping to determine the Web IP addressOpen Connect as a Telnet clientTelnet tips Set carriage return-line feed Escape character and Esc keyLocal echo CloseEthernet Connection, cont’d AppendixBB Specifications Integration Scaling Matrix Switcher Reference InformationAudio Reference Information, cont’d Optional accessoriesCables and connectors Part NumbersBNC-5 Mini HR Cable Assorted connectors BNC connectorsBNC-4 Mini HR Cable Plenum BNC-5 Mini HR CableFirmware Upgrade Installation Figure B-1 Removing the ISM cover Button Labels Integration Scaling Matrix Switcher Reference Information Reference Information, cont’d FCC Class B Notice Extron Electronics, USA