Extron electronic ISM 182 Escape character and Esc key, Local echo, Set carriage return-line feed

Page 83

Escape character and Esc key

When Telnet is first started, the utility advises that the Escape character is ‘Ctrl+]’. Many SIS commands include the keyboard Esc key. Consequently, some confusion may exist between the Escape character and the Escape key.

The Telnet Escape character is a key combination, the Ctrl key and the ] key pressed simultaneously, that returns you to the Telnet prompt while leaving the connection to the ISM intact.

The Escape key is the Esc key on the computer keyboard.

Local echo

Once connected to the ISM, by default Telnet does not display your keystrokes on the screen. SIS commands are typed in blindly and the SIS responses are displayed on the screen. To command Telnet to show keystrokes, at the Telnet prompt, type set local_echo and then press [Enter] before you open the connection to the switcher.

With local echo turned on, keystrokes and the switcher’s response are displayed on the same line. For example: 1*1!In1 Out1 All, where 1*1! is the SIS command and In1 Out1 All is the response.

With local echo turned on, all keystrokes are displayed, even those that should be masked, such as the password entry. For example, when entering a password with local echo turned on, you will see a display such as a*d*m*i*n*, where admin is the keyed in password and ***** is the masked response.

Local echo can be turned off by typing unset local_echo and then pressing [Enter] at the Telnet prompt. If you are connected to the ISM and need to access the Telnet prompt to turn local echo off, type the Escape character ( Ctrl + ] ).

Set carriage return-line feed

Unless commanded otherwise, Telnet transmits a line feed character only (no carriage return) to the connected ISM when you press the Enter key. This is the correct setting for SIS communication with the switcher. The Telnet set crlf command forces Telnet to transmit carriage return and line feed characters when Enter is pressed, but if crlf is set, the SIS link with the switcher will not function properly.

Close

To close the link to the switcher, access the Telnet prompt by typing the Escape character ( Ctrl + ] ). At the Telnet prompt, type close and then press [Enter].

Help

For Telnet command definitions, at the Telnet prompt, type ? and then press [Enter].

Quit

Exit the Telnet utility by typing quit and then press [Enter] at the Telnet prompt. If you are connected to the ISM, access the Telnet prompt beforehand by typing the Escape character ( Ctrl + ] ).

Integration Scaling Matrix Switcher Ethernet Connection

A-5

Image 83
Contents ISM 482 & ISM Integration Scaling Matrix SwitchersInstrucciones de seguridad Español Safety Instructions EnglishConsignes de Sécurité Français Sicherheitsanleitungen DeutschQS-1 Quick Start Integration Scaling Matrix SwitcherQS-2 Quick Start Integration Scaling Matrix Switcher, cont’dTable of Contents Table of Contents, cont’d Integration Scaling Matrix Switcher Table of Contents Iii Iv Integration Scaling Matrix Switcher Table of Contents One About this Manual About the SwitcherIntegration Scaling Matrix Switcher Introduction Introductiontroduction, cont’dExtron ISM Introduction, cont’d FeaturesIntegration Scaling Matrix Switcher Introduction Introduction, cont’d Two Integration Scaling Matrix Switcher Installation Installationstallation, cont’dMounting the Switcher Tabletop placementInput connections Cabling and Rear Panel ViewsCaptive screw connector wiring for inputs Installation, cont’dBNC output connections for Rgbhv and Rgbs video Output connectionsChoosing a network cable Cabling and RJ-45 connector wiringEthernet connection RJ-45 connector pinout tables Wiring the network cableRS-232 connection ConfigurationThree Video/Audio selection button and LEDs Front Panel Controls and IndicatorsIntegration Scaling Matrix Switcher Operation Operationeration, cont’dFront panel input label window Outputs buttons and LEDsInput buttons, LEDs, and label window Black/Mute button and LEDs Picture adjustment buttonsOperation, cont’d Menu control buttons Adjustment knobsLCD display Front Panel Operations PowerExtron Electronics ISM 60-425-01 Version Menu system overviewInput Configuration submenu Video & Audio Configuration menuOutput Resolution submenu Output Configuration menuSync Type and Polarity submenu Resolution 50 Hz 56 Hz 60 Hz 75 Hz 85 Hz Lock at 50/60 HzVideo & Audio Advanced Configuration menuBlanking submenu Blue Only Mode and Edge Smoothing submenuRGB Delay submenu Test Pattern submenuReset submenu Enhanced Mode submenuPixel Phase submenu PAL Film Mode submenuSave Preset submenu User Presets menuExit menu Erase Preset submenu13 Picture adjustments flowchart Picture adjustments14 Front panel security lockout flowchart Front panel security lockout executive modeIP information Optimizing the VideoControls to position the image Setting up a DVD sourceGeneral checks TroubleshootingOptimizing the Audio Problem Cause Specific problemsOperation, cont’d Four Ethernet Link Integration Scaling Matrix Switcher Programmer’s GuideRS-232 Link Default address SymbolsInput and output video type Switcher-Initiated MessagesPower-up Ties creationX2 Col Programmer’s Guide, cont’d Using the command/response table Host-to-Switcher InstructionsSwitcher error responses Command Ascii Command Response Additional description Vertical size BrightnessContrast Horizontal sizeVertical detail filter RGB and component video inputs Pixel phaseBottom blanking Horizontal detail filter RGB and component video inputsTest pattern User presetsAuto Memories FreezeInformation requests Executive modeVerbose mode Resets Command/response table for IP SIS commandsScaler settings Command/response table for special function SIS commandsDelay times Edge smoothing Enhanced modePAL film mode Blue screenAdditional description Command Hex Command ResponseMemory backup Five Control Software for Windows Installing the softwareEthernet protocol settings Integration Scaling Matrix Switcher Switcher SoftwareIf you selected a comm port, proceed to step Using the control programWindows Control program window Switcher Software, cont’dButton-Label Generator Using the help programUsing the software Installing the softwareSix Load the Startup Control Integration Scaling Matrix Switcher Ethernet OperationEthernetOperation,cont’d Control Create a tie Change the RGB delayEthernet Operation, cont’d ControlPreview the scan rate Executive modeFreeze the output Output a test patternSystem Configuration System ConfigurationISM Name field Administration fieldsISM IP Settings fields ISM IP Address fieldFile Management File ManagementI/O Configuration Input configurationOutput resolution, rate, sync format, and polarity Output rate Output resolutionOutput polarity Output formatAAppendix a Ethernet Connection, cont’d Integration Scaling Matrix Switcher Ethernet ConnectionPing to determine the Web IP address Ping to determine the switcher’s IP addressOpen Connect as a Telnet clientTelnet tips Close Escape character and Esc keyLocal echo Set carriage return-line feedEthernet Connection, cont’d AppendixBB Integration Scaling Matrix Switcher Reference Information SpecificationsAudio Part Numbers Optional accessoriesCables and connectors Reference Information, cont’dPlenum BNC-5 Mini HR Cable Assorted connectors BNC connectorsBNC-4 Mini HR Cable BNC-5 Mini HR CableFirmware Upgrade Installation Figure B-1 Removing the ISM cover Button Labels Integration Scaling Matrix Switcher Reference Information Reference Information, cont’d FCC Class B Notice Extron Electronics, USA
Related manuals
Manual 3 pages 47.89 Kb