Extron electronic ISM 182 manual Symbols, Default address

Page 47

Ethernet connection

The cable can be terminated as either a patch cable or a crossover cable (figure 4-2) and must be properly terminated for your application:

Patch (straight) cable — Connection of the ISM to an Ethernet hub, router, or switcher that also hosts a controlling computer.

Crossover cable — Direct connection between the ISM and a computer.

Default address

To access the switcher via the Ethernet port, you will need the switcher’s IP address. If the address has been changed to an address comprised of words and characters, the actual numeric IP address can be determined using the front panel (see IP information in chapter 3, Operation) or the Ping utility (see Ping to determine the switcher’s IP address or Ping to determine the Web IP address in appendix A, Ethernet Connection, for more details). If the address has not been changed, the factory- specified default is 192.168.254.254.

Symbols

Symbols ( Xn values), defined below, are used throughout the discussions of the switcher-initiated messages that begins on the next page and the command/ response table that begins on page 4-8. The symbols represent variables in the switcher-initiated messages and the command/response table fields.

= CR/LF (carriage return/line feed) (hex 0D 0A)

= CR (no line feed)

= Space

Esc = Escape key

X1

= Input number 1 through 8

 

X2

= Output number 1 or 2

 

 

X3

= 000 = off, 001 = on

 

 

 

X4

= Input video type:

 

 

 

 

000

= RGB

005

= Betacam 60

 

001

= RGBcS

006

= HDTV

 

002

= YUVi

007

= S-video

 

003

= YUVp

008

= Composite

 

004

= Betacam 50

 

 

 

X5

= Scaler resolution:

 

 

 

 

00

= 640x480

08

 

= 1360x765

 

01

= 800x600

09

 

= 1365x1024

 

02

= 832x624

10

 

= 720p*

 

03

= 848x480

11

 

= 1080p

 

04

= 852x480

12

 

= 1080i

 

05

= 1024x768*

13

 

= 1400 x 1050

 

06

= 1280x768*

14

 

= 576p

 

07

= 1280x1024*

 

 

 

X6

= Video refresh rate:

 

 

 

 

000

= 50 Hz

003

= 75 Hz

 

001

= 56 Hz

004

= 85 Hz

 

002

= 60 Hz

005

= AFL*

 

 

 

 

Lock or AFL is Accu-RATE Frame Lock

 

 

 

 

 

 

 

 

(PAL = 50 Hz, NTSC =59.94 Hz)

X7

= Output video type:

 

00 = RGBHV, 01 = RGBS

X8

= Output sync polarity:

 

 

 

 

00

= H–/V–

02

= H+/V–

 

01

= H–/V+

03

= H+/V+

X9

= Color value (0 thru 127)

 

 

X10 = Tint value (0 thru 255)

X11

= Brightness and contrast value (000 thru 63)

 

= Size value (range depends on the resolution)

X12

 

= Centering value (range depends on the resolution)

X13

 

= Blanking value (000 thru 200)

X14

 

= Pixel sampling phase (000 through 031)

X15

 

= Horizontal filter value (000 thru 003)

X16

 

= Vertical filter or composite/S-video detail filter (001 thru 007)

X17

 

= Preset number (01 thru 03)

X18

 

= Output 1/ Output 2 selection:

X19

 

Output 1/Output 2

Output 1/Output 2

 

00 = Off/Off

02 = Off/On

 

01 = On/Off

03 = On/On

 

= RGB delay in 0.01 second steps (00 [no delay] to 50 [5.0 secs])

X20

 

= Test pattern type (1 through 10):

X21

 

001 = Color Bars

006

= alternating pixels

 

002 = crosshatch

007

= film aspect ratio 1.78

 

003 = 4x4 crosshatch

008

= film aspect ratio 1.85

 

004 = gray scale

009

= film aspect ration 2.35

 

005 = crop

010

= ramp

 

= Gain/attenuation (–24dB to +9dB, each step = 1dB)

X22

 

= Gain value (numeric dB value, 0 to +9)

X23

 

= Attenuation value (numeric dB value, –1 to –24)

X24

 

= nnn.nn where

 

 

X25

 

 

 

Hrt = horizontal rate (kHz)

 

 

Vrt = vertical rate (Hz)

 

 

 

xxx:xx means signal out of range

 

= Detected input signal standard (0 through 4):

X26

0 = none

1 = NTSC 3.58

2 = PAL

3 = NTSC 4.43

4 = SECAM

= not applicable (occurs when the input is set for RGB, YUV, or progressive YUV)

Integration Scaling Matrix Switcher • Programmer’s Guide

4-3

Image 47
Contents ISM 482 & ISM Integration Scaling Matrix SwitchersInstrucciones de seguridad Español Safety Instructions EnglishConsignes de Sécurité Français Sicherheitsanleitungen DeutschQS-1 Quick Start Integration Scaling Matrix SwitcherQS-2 Quick Start Integration Scaling Matrix Switcher, cont’dTable of Contents Table of Contents, cont’d Integration Scaling Matrix Switcher Table of Contents Iii Iv Integration Scaling Matrix Switcher Table of Contents One About this Manual About the SwitcherIntegration Scaling Matrix Switcher Introduction Introductiontroduction, cont’dExtron ISM Introduction, cont’d FeaturesIntegration Scaling Matrix Switcher Introduction Introduction, cont’d Two Integration Scaling Matrix Switcher Installation Installationstallation, cont’dMounting the Switcher Tabletop placementInput connections Cabling and Rear Panel ViewsCaptive screw connector wiring for inputs Installation, cont’dBNC output connections for Rgbhv and Rgbs video Output connectionsChoosing a network cable Cabling and RJ-45 connector wiringEthernet connection RJ-45 connector pinout tables Wiring the network cableRS-232 connection ConfigurationThree Video/Audio selection button and LEDs Front Panel Controls and IndicatorsIntegration Scaling Matrix Switcher Operation Operationeration, cont’dFront panel input label window Outputs buttons and LEDsInput buttons, LEDs, and label window Black/Mute button and LEDs Picture adjustment buttonsOperation, cont’d Menu control buttons Adjustment knobsLCD display Front Panel Operations PowerExtron Electronics ISM 60-425-01 Version Menu system overviewInput Configuration submenu Video & Audio Configuration menuOutput Resolution submenu Output Configuration menuSync Type and Polarity submenu Resolution 50 Hz 56 Hz 60 Hz 75 Hz 85 Hz Lock at 50/60 HzVideo & Audio Advanced Configuration menuBlanking submenu Blue Only Mode and Edge Smoothing submenuRGB Delay submenu Test Pattern submenuReset submenu Enhanced Mode submenuPixel Phase submenu PAL Film Mode submenuSave Preset submenu User Presets menuExit menu Erase Preset submenu13 Picture adjustments flowchart Picture adjustments14 Front panel security lockout flowchart Front panel security lockout executive modeIP information Optimizing the VideoControls to position the image Setting up a DVD sourceGeneral checks TroubleshootingOptimizing the Audio Problem Cause Specific problemsOperation, cont’d Four Ethernet Link Integration Scaling Matrix Switcher Programmer’s GuideRS-232 Link Default address SymbolsInput and output video type Switcher-Initiated MessagesPower-up Ties creationX2 Col Programmer’s Guide, cont’d Using the command/response table Host-to-Switcher InstructionsSwitcher error responses Command Ascii Command Response Additional description Vertical size BrightnessContrast Horizontal sizeVertical detail filter RGB and component video inputs Pixel phaseBottom blanking Horizontal detail filter RGB and component video inputsTest pattern User presetsAuto Memories FreezeInformation requests Executive modeVerbose mode Resets Command/response table for IP SIS commandsScaler settings Command/response table for special function SIS commandsDelay times Edge smoothing Enhanced modePAL film mode Blue screenAdditional description Command Hex Command ResponseMemory backup Five Control Software for Windows Installing the softwareEthernet protocol settings Integration Scaling Matrix Switcher Switcher SoftwareIf you selected a comm port, proceed to step Using the control programWindows Control program window Switcher Software, cont’dButton-Label Generator Using the help programUsing the software Installing the softwareSix Load the Startup Control Integration Scaling Matrix Switcher Ethernet OperationEthernetOperation,cont’d Control Create a tie Change the RGB delayEthernet Operation, cont’d ControlPreview the scan rate Executive modeFreeze the output Output a test patternSystem Configuration System ConfigurationISM Name field Administration fieldsISM IP Settings fields ISM IP Address fieldFile Management File ManagementI/O Configuration Input configurationOutput resolution, rate, sync format, and polarity Output rate Output resolutionOutput polarity Output formatAAppendix a Ethernet Connection, cont’d Integration Scaling Matrix Switcher Ethernet ConnectionPing to determine the Web IP address Ping to determine the switcher’s IP addressOpen Connect as a Telnet clientTelnet tips Close Escape character and Esc keyLocal echo Set carriage return-line feedEthernet Connection, cont’d AppendixBB Integration Scaling Matrix Switcher Reference Information SpecificationsAudio Part Numbers Optional accessoriesCables and connectors Reference Information, cont’dPlenum BNC-5 Mini HR Cable Assorted connectors BNC connectorsBNC-4 Mini HR Cable BNC-5 Mini HR CableFirmware Upgrade Installation Figure B-1 Removing the ISM cover Button Labels Integration Scaling Matrix Switcher Reference Information Reference Information, cont’d FCC Class B Notice Extron Electronics, USA