You can also connect an MKP 1000 remote keypad or MCP 1000 slave unit to the MCP 1000 master unit. Refer to the MCP 1000 Remote Control Panel User’s Manual and the MKP 1000 User’s Manual for details.
See chapter 4, Programmer’s Guide, for definitions of the SIS commands and chapter 5, Matrix Software for details on how to install and use the control software.
The Matrix 50 Series Switchers are factory configured for
External sync connection
When the switching between inputs, the resulting image change should be seamless, or clean. The Matrix 50 Series switchers can use an external signal to synchronize switching during the vertical interval. Without the external sync locking feature, switching between inputs can result in a brief rolling (sync loss) or a brief change in the picture size.
7External Sync In connector — Connect an external sync signal to this BNC connection for genlocking the video signal in broadcast or other
External Sync Out connector — Connect any downstream equipment that requires genlocking to this BNC connector to route the external sync signal throughout the system in broadcast or other
Figure 2-8 shows a basic external sync configuration. The Ext Sync In connector receives a timing signal. The Ext Sync Out connector allows the signal to be passed on to another video device, if required.
Figure 2-9 shows a configuration in which the timing source passes through three video cameras and a video scan converter before connecting to the switcher. This type of video camera is capable of synchronizing with the external timing source for video editing applications.
If no external sync timing source is connected to the switcher, switching occurs immediately.
Timing source
Matrix 50
switcher
OUT |
To next device
Figure 2-8 —Simple external sync connection example
Matrix 50 Series Switchers • Installation |