Tripp Lite B064-016-02-IPG, B064-032-04-IPG Hardware Setup, General Safety Instructions

Page 7

Hardware Setup

General Safety Instructions

Read all of these instructions. Save them for future reference.

Follow all warnings and instructions marked on the device.

Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.

This device is designed for IT power distribution systems with up to 230V phase-to-phase voltage.

Do not place the device on any unstable surface (cart, stand, table, etc.). If the device falls, serious damage will result.

Do not use the device near water.

Do not place the device near, or over, radiators or heat registers.

The device cabinet is provided with slots and openings to permit adequate ventilation. To ensure reliable operation and protect against overheating, these openings must never be blocked or covered.

The device should not be placed on a soft surface (bed, sofa, rug, etc.), as this will block its ventilation openings. Likewise, the device should not be placed in a built-in enclosure unless adequate ventilation has been provided.

Never spill liquid of any kind on the device.

Unplug the device from the wall outlet before cleaning. Use a damp cloth for cleaning. Do not use liquid or aerosol cleaners.

The device should be operated from the type of power source indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company.

To prevent damage to your installation, ensure that all devices are properly grounded.

The device is equipped with a 3-wire grounding type plug. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not attempt to defeat the purpose of the grounding-type plug. Always follow your local/ national wiring codes.

Position system cables and power cables carefully to ensure that nothing rests on any cable. Route the power cord and cables so that they cannot be stepped on or tripped over.

If an extension cord is used with this device, make sure that the total ampere rating of all products used on the cord does not exceed the extension cord ampere rating. Make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes.

To help protect your system from sudden transient increases and decreases in electrical power, it is recommended that you plug your devices into a Tripp Lite surge suppressor, line conditioner, or uninterruptible power supply (UPS).

When connecting or disconnecting power to hot-pluggable power supplies, observe the following precautions:

>Install the power supply before connecting the power cable to the power supply

>Unplug the power cable before removing the power supply

>If the system has multiple sources of power, disconnect power from the system by unplugging all power cables from the power supplies

>Never push objects of any kind into or through cabinet slots. They may touch dangerous voltage points or short out parts, resulting in a risk of fire or electrical shock

>Do not attempt to service the device yourself. Refer all servicing to qualified service personnel

If the following conditions occur, unplug the device from the wall outlet and bring it to qualified service personnel for repair:

>The power cord or plug has become damaged or frayed

>Liquid has been spilled into the device

>The device has been exposed to rain or water

>The device has been dropped or the cabinet has been damaged

>The device exhibits a distinct change in performance, indicating a need for service

>The device does not operate normally when the operating instructions are followed

Adjust only those controls that are covered in the operating instructions. Improper adjustment of other controls may result in damage that will require extensive repair work by a qualified technician.

Do not connect the RJ11 connector marked “UPGRADE” to a public telecommunication network.

7

Image 7
Contents Models NetDirector Cat5 IP KVM SwitchesTable of Contents Introduction FeaturesRemote Console Computer Requirements Supported Operating Systems Supported Video ResolutionsConnected Computer/Server Requirements Server Interface Units SIUsNo.. Component Description Supported BrowsersComponents Front ViewRear View General Safety Instructions Hardware SetupRack Mounting Single-Stage InstallationRack Mounting Safety Instructions StackingTwo-Stage Installation Hot Plugging Powering Off & RestartingSingle-Stage Installations Two-Stage InstallationsLocal Console Super Administrator SetupFirst Time Setup Network Setup IP Address DeterminationRedundant NIC IP InstallerNIC Settings BrowserChanging the Super Administrator Login Logging Into the B064-Series KVM SwitchLocal Console Login AP Windows Client Login Browser LoginConnection Screen AP Java Client LoginFile Menu AP Client Main OSD OperationOSD Main Web Browser MainIcon Description Port AccessOSD Tab Bar Local Console MainInternet Explorer ConnectionsNon-Windows Browser Scan Panel Array ModePort Selection List Port NamingSection Description HistoryPort Level Attribute DescriptionAdding a Favorite FavoritesModifying a Favorite Scan Duration Setting DescriptionDisable it. The default setting is enabled User PreferencesSessions AccessVirtual media mounted to the selected port Port ConfigurationAccess Click until you toggle to the desired settingAssociated Link Port PropertyTime. Choices are Exclusive, Occupy and Share Adding User Accounts User ManagementField Description Groups Creating Groups Modifying User AccountsDeleting User Accounts GroupsGroups Deleting Groups Groups Modifying GroupsAssigning Users to Groups Removing Users From a Group via the User’s Notebook Assigning Users to a Group via the User’s NotebookRemoving Users From a Group via the Group’s Notebook Assigning Users to a Group via the Group’s NotebookDevice Assignment OSD Operation for details Power Supply DetectionDevice Management Device InformationNetwork Operating ModeWhen using them to connect to the KVM switch Advanced Network Management Settings Ldap / Ldaps Authentication and Authorization Settings AuthenticationDisable Local Authentication Radius SettingsInstall the Active Directory Schema Snap-in Install the Windows 2003 Support ToolsCreating a Start Menu Shortcut Entry Minimum Maximum Extend and Update the Active Directory SchemaSelect New Attribute Common Name userprofile Ldap Display Name userprofileClick Edit to bring up the String Attribute Editor OpenLDAP Server OpenLDAP Server InstallationLdap DIT Design and Ldif File OpenLDAP Server ConfigurationCustomizing the OpenLDAP Schema Starting the OpenLDAP ServerDIT Creation Using the New SchemaEnable Dial Out Enable Dial BackSecurity Connection Setup Example Windows XPTo delete an IP filter Login FailuresFiltering IP FilteringAccount Policy MAC Filtering Login StringEncryption Private Certificate Working ModeCertificate Signing Request Email Address Administrator@yourcompany.comField Example Time Zone Date/TimeNetwork Time Log Notification SettingsLog Information Main Screen MaintenanceUpgrade Main Firmware Main Firmware Upgrade RecoverySIU Firmware Upgrade Recovery Upgrade AdaptersPing Host Backup/RestoreBackup RestoreDownload Reset on ExitSystem Operation Control Panel Remote Session OperationHotkey Description HotkeysSystem Macros User MacrosRGB Choosing a pre-determined configurationGamma Adjustment Message Display Panel USB Ports on Front Panel of KVM SwitchUser List Panel Compose PanelVirtual Media via Remote Session Virtual MediaMac and Linux Considerations Virtual Media via Local ConsoleWindows XP and later Mouse Synchronization ProceduresManual Mouse Synchronization WindowsRemote Session Operation Remote Session Operation Icon in the Toolbar OSD ToolbarToolbar Hotkeys Hotkey ActionPanel Array Toolbar Auto Scanning Multiuser OperationMenu Bar InstallationLog Server Starting UpDelete ConfigureAdd EditEvents MaintenanceSearch Log Server Main Screen Overview Contents Network RetryOptions HelpThey will not be able to communicate List PanelEvent Panel RecordingAppendix General Operation TroubleshootingAdministration Troubleshooting Problem ActionVirtual Media Troubleshooting Mouse TroubleshootingAP Windows Client Troubleshooting Panel Array Mode Troubleshooting WinClient ActiveX Viewer TroubleshootingJava Applet & AP Java Client Troubleshooting Sun Systems Troubleshooting Log Server TroubleshootingSwitch RJ45 Pins Modem DB9 SpecificationsFactory Default Settings Setting DefaultFan Location & Speed Information Temperature Sensor LocationFan Speed Year Limited Warranty Warranty Registration
Related manuals
Manual 4 pages 42.85 Kb

B064-016-02-IPG, B064-032-02-IPG, B064-016-04-IPG, B064-032-04-IPG specifications

The Tripp Lite B064-032-04-IPG is a highly efficient and versatile KVM switch that offers seamless control over multiple computers or servers from a single console. This device is engineered for professionals and IT administrators who require robust management of servers or machines located in different physical locations, particularly in demanding environments like data centers or server rooms.

One of the standout features of the B064-032-04-IPG is its ability to facilitate access to up to 32 computers using a single set of keyboard, video monitor, and mouse. This not only streamlines workflows but also reduces clutter, as users no longer need multiple sets of peripherals for each machine. The switch supports both USB and PS/2 connection types, making it compatible with a wide range of devices.

The B064-032-04-IPG leverages advanced technology to offer a responsive and high-resolution video output, supporting resolutions up to 1920 x 1200. This ensures that users can easily view and interact with multiple systems without sacrificing visual quality. Additionally, the switch features a built-in web interface that allows administrators to configure settings with ease, enabling effective management in remote or local scenarios.

Security is a top priority with the B064-032-04-IPG, which supports user authentication and multi-level password protection. This guarantees that only authorized personnel can access sensitive systems, bolstering the overall security posture of the network. Furthermore, the switch includes features for firmware updates, ensuring that it stays current with the latest security protocols and enhancements.

Another key characteristic of this KVM switch is its support for hot-swappable functionality, which allows users to add or remove servers without needing to power down the entire system. This greatly enhances operational efficiency and minimizes downtime during maintenance or upgrades.

Built with a sturdy and reliable design, the Tripp Lite B064-032-04-IPG is suitable for various environments, including those that require ruggedness and durability. Its compact form factor makes installation straightforward, and its fanless design ensures silent operation, which is ideal for noise-sensitive areas.

In conclusion, the Tripp Lite B064-032-04-IPG is a powerful KVM switch that combines multiple advanced features, technologies, and characteristics, making it an excellent choice for large-scale server management. With its ease of use, security features, and high performance, it provides a seamless solution for IT professionals looking to optimize their hardware management in complex environments.