Network Technologies CS-16/8 Advanced Settings, Change administrator password, Keypad

Page 28

NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH

3.1.6 Advanced Settings

From the "Administrator main menu", press [7] to display the “Advanced settings” menu.

 

Figure 18- Administrator's Advanced settings menu

From the "Advanced settings" menu the administrator can perform the following functions:

 

 

 

Setting

Description

Value

Administrator

Define the password to be used by the

Max. 31 characters.

Password

administrator

This can only be changed if old password is known.

 

 

(If SERIMUX is re-initialized (pg 30), the default password

 

 

(“nti”) will be restored)

Administrator

the time interval of administrator

0-90 minutes 0 = Never

Timeout

inactivity, prior to logging out.

 

Unit name

Name assigned to the SERIMUX

Max. 40 characters

User to auto login

User assigned to automatically login at

Index number of any enabled user that has access to the port

 

power up without a password.

being used for the user port

 

 

 

Connect two host

Connect two host ports together

Enter host port index number, press [Enter], second host port

ports

 

index number, and press [Enter] again

Firmware

Display the firmware menu

See pg. 19

Auto Refresh Period

Refreshes the admin screen after xx

0-90

 

minutes

 

Local KeyPad PIN

Defines the PIN number for Local

4 digit value 0000-9999 (default value is 9999)

 

keypad

 

FYI: If at power up the auto-login user does not have access to port being used, a login by a valid user with access rights will be required.

3.1.6.1 Change administrator password

For security purposes the administrator should change the factory default administrator password to a unique password. This will prevent unauthorized access to switch functions and CPUs. The password is needed to log in from any device, connected to any SERIMUX port in buffer mode.

To change the administrator password, from the Administrator main menu;

-press [7] to choose Advanced settings and press [Enter]. The Advanced settings menu will appear (Figure 18)

-press [1] and a prompt for the old password will appear

-enter the old password (factory default password is "nti") and press [Enter]

-enter a new password (maximum 31 ASCII characters), using the [Backspace] key to erase any characters entered in error, and press [Enter]

-re-enter the password to confirm it, and press [Enter]

-a message "OK" will appear, press any key to return to the Advanced settings menu

Note: The password entered will be case sensitive so be sure to note what characters are used and what case they are in if any are alphabetical. The password characters are displayed as ‘*’ (asterisk) characters while entering them.

Note: If the administrator password is not known, the administrator must re-initialize the SERIMUX following the "Reset SERIMUX Console Switch to default settings" instructions on page 30.

23

Image 28
Contents SERIMUX-TERM-CS-16/8 Trademark Table of Contents 1 VT100, VT220 and Console Ansi Command Guide Table of Figures Features IntroductionTerminal Converter Multiple RS-232 EmulationsConsole Switch Materials DB25M-RJ45F-C DB9F-RJ45FFeatures and Functions Front and Rear Views of SERIMUX-TERM-CS-16Rack Mounting Instructions Installation#10-32x3/4 Rack Screws supplied Cage Nuts Supplied Connect Devices, Hosts, and Power IEC Power ConnectorPowercord RJ45 Male ConnectorPower Up The SERIMUX-TERM-CS-16 Connect the Serimux and Terminal to a NetworkConnect the Monitor and Keyboard MonitorSetup The Terminal Getting StartedSaving and Exiting Setup F2- Genrl Setup MenuF4- Comm Setup Menu Connect to the SerimuxStartup- Accessible host list Using the Serimux Console Switch Default keypad PIN number isTerminal Control Serial ControlAdministrator Controls Login as the administratorPort List Port list displays the status of all portsPort Settings Port settings menuSetting Description Value Port serial settings Data bitStop Bit ParityFlow control Command Inter-character delayXon or Xoff Characters DTR line behaviorModem settings Copy Port Serial SettingsDisplay serial settings for different port number Function KeystrokePort data buffer Display modem settings for different port numberClear Port data buffer User List User ListUser Settings User settings menuCopy User Settings Port accessOption Description Advanced Settings Change administrator passwordSetting Description Value Local KeyPad PIN Defines the PIN number for LocalFunction Description FirmwareLoad new firmware Save current firmware Serimux is waiting to save its firmware User Accessible host list screen User ControlsUser main menu User main menuLimited user accessible Port list Port List screenUser Terse mode Terse mode commands ¾ Connect to port¾ Accessible host list ¾ Port info¾ Verbose mode System Reset button¾ User Logout Firmware Upgrade Firmware upload windowLast confirmation before firmware update Login the administrator Keypad ControlFunctions of the Keypad Action from Keypad Reaction of SerimuxLogin a user to the administrator main menu Login user to a portConnect 2 host ports Disconnect and logout a userAction from Keypad Disconnect 2 ports Reset Serimux Console Switch to default settingsTo detach a modem Using the Terminal How To Setup The TerminalF2- Genrl Setup Menu F1- Disp Setup MenuChanging The Terminal Operating Parameters F4- Comm Setup Menu F3- Keybd Setup MenuPrinter F5- Misc Setup Menu F7- FKeys SET-UP Definition Setup MenuF6-Tabs SET-UP Menu Printer RCV ON/OFFF9- Lan Setup Menu F8- Ansbk SET-UP MenuF10- Colr1 Set-up Menu Programmable KeysColor Association = OFF/ON Color Setup Menu F11- Colr2 Set-up MenuAttribute = Bold/Blink OptionColor Palettes Palette Display Attribute Foreground Color Background ColorColor Palettes Contd Local Keyboard Commands Command Enhanced PCTerminal Command Guide Commands Supported in Ascii PersonalitiesSame WyseNative Mode Wyse Select bell volumeStop parity word Key/fkey DELSequence DEL Key/fkey Sequence Sequence DELESC . cursor1 Message CRESC a mf attr AttrFcolor Bcolor mapLine col ColCcc C Clearing Data Editing ContdSending data Print Functions Character SetsSet Pp bb...bbVariable Values for Commands Variable Values for Commands Contd Length Line/ColumnDefinition Max Maximum SpeedBell Volume Function KeyPalette Color Pallette Parity Bits1 VT100, VT220 and Console Ansi Command Guide Ansi Command GuideSupported VT100,VT220 and Console Ansi Commands Supported VT100, VT220 and Console Ansi Commands, Contd Character Set SelectionESC Ps final Label assignedSupported VT100, VT220 and Console Ansi Commands Contd Final characterValues for Ps above Character AttributeValues for Psn in table on Editing FunctionsClear Key Lock See tables below an on next page for values Kc/hc ST StringShifted function key Redefine keys with string Unshifted function keyKey Value Values of Fn for Numeric Keypad keysMore Terminal Control Commands Terminal ResetsAuxiliary Keypad Modes Transmission/Printer Control2 VT52 Command Guide Command VT52See table below for values of Ps Keyboard LanguageUsing Printer Server via Ethernet Connection Basic SetupSetup for LPD LPD printing Setup for TftpTftp Printing Hardware Specifications Serimux Hardware Specifications TerminalHardware Information Pin assignment at Wire Color Standard End Crossed End CPU-to-RACKMUX Ethernet Crossover CableSerial Port Cabling Serial Port PinoutsRJ45 Signal Cable AdaptersDB25F Terminal Connector Pin Assignments SUB-D Female connector3 4 Mating face of an RJ45 FemaleAppendix a Serimux Port Characteristics Description Acceptable Value Default ValueAppendix B Serimux User and Administrator Characteristics AdministratorWarranty Information Index