Network Technologies CS-16/8 Appendix a Serimux Port Characteristics, Users, Administrator

Page 78

NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH

Appendix A - SERIMUX Port Characteristics

Every port is defined through the following parameters:

 

Description

 

 

Acceptable Value

 

 

Default Value

 

 

 

 

 

 

 

 

Number

0-8/16/24/32

 

Same (not changeable)

 

Name

 

Up to 15 characters

 

 

“Port00” to “Port32”

 

Type – port 0

 

User

 

 

User (not changeable)

 

Type – except port 0

 

User or Host

 

 

Host

 

Baud rate – port 0

300-115200

 

9600

 

 

Baud rate – except port 0

50-128000

 

9600

 

 

Data bits per character – port 0

7,8

 

8

 

 

Data bits per character – except port 0

5,6,7,8

 

8

 

 

Stop bits – port 0

1, 2

 

1

 

 

Stop bits – except port 0

1, 1-1/2, 2

 

1

 

 

Parity

No parity, even, odd

 

 

No parity

 

Handshake mode (flow control)

 

Xon / Xoff (or in-band, or software),

 

None

 

 

 

 

RTS/CTS (or out-band or hardware),

 

 

 

 

 

 

 

Both,

 

 

 

 

 

 

 

 

None

 

 

 

 

 

Xon character

 

any ASCII nonprintable character

(0-31 range)

 

Ctrl+Q (17)

 

Xoff character

any ASCII nonprintable character

(0-31 range)

 

Ctrl+S (19)

 

Inter-character delay – except port 0

 

1-60 milliseconds, none

 

 

None

 

(no delay allowed on port 0)

 

 

 

 

 

 

 

Line break receive allowance – except port 0

 

Yes or No

 

 

No

 

(no allowance for port 0)

 

 

 

 

 

 

 

Transmitted line break extra duration (added

 

No break transmitted, 1-999 milliseconds

 

No break transmitted

 

to 1 character transmission time) – except

 

 

 

 

 

 

 

port 0 (no extra duration for port 0)

 

 

 

 

 

 

 

In-band disconnect sequence

 

0 (disabled), 1, or 3 characters sequence

 

1-char sequence

 

 

 

 

 

 

 

1 character disconnect sequence

 

Any ASCII nonprintable character (0-31 range)

 

Ctrl+X (24)

 

3 character disconnect sequence

 

Any 3 ASCII characters

 

 

``` (3 back quotes)

 

Connection timeout

 

1-90 minutes, never

 

 

15 minutes

 

DTR output upon disconnect

 

Low, high, or pulsed for 0.5 seconds and then held

 

High

 

 

 

 

high

 

 

 

 

 

Modem Reset string

 

Up to 41 characters

 

 

ATZ

 

Modem Initialization string

 

Up to 41 characters

 

 

AT&F&C1&D2S0=0

 

Modem Disconnect string

 

Up to 41 characters

 

 

ATH

Appendix B - SERIMUX User and Administrator Characteristics

The users and the administrator are defined through the following parameters:

 

Description

 

 

Acceptable Value

 

 

Default Value

 

 

 

 

 

 

 

 

Users:

 

 

 

 

 

 

 

User number

 

1 to 32

 

Same (not changeable)

 

User name

 

Up to 15 characters – case sensitive

 

“User01” to “User32”

 

User password

 

Up to 31 characters – case sensitive

 

“” (empty string)

 

User enabled

 

Yes or No

 

Not enabled, except

 

 

 

 

 

 

 

User 1: enabled

 

Administrative privileges

 

Yes or No

 

No

 

Access to ports

 

Port 0 always; Ports 1-31

 

Port 0, except

 

 

 

 

 

 

 

User 1: all ports

 

User menu timeout

 

1-90 minutes, never

 

15 minutes

 

Administrator:

 

 

 

 

 

 

 

Administrator name

“root” – case sensitive

Same (not changeable)

 

Administrator password

Up to 31 characters – case sensitive

 

“nti”

 

Administrator menu timeout

1-90 minutes, never

 

15 minutes

 

User to auto login

 

User 1-32, None

 

User 1

73

Image 78
Contents SERIMUX-TERM-CS-16/8 Trademark Table of Contents 1 VT100, VT220 and Console Ansi Command Guide Table of Figures Terminal Converter FeaturesIntroduction Multiple RS-232 EmulationsConsole Switch Materials DB25M-RJ45F-C DB9F-RJ45FFeatures and Functions Front and Rear Views of SERIMUX-TERM-CS-16Installation Rack Mounting Instructions#10-32x3/4 Rack Screws supplied Cage Nuts Supplied Powercord Connect Devices, Hosts, and PowerIEC Power Connector RJ45 Male ConnectorConnect the Monitor and Keyboard Power Up The SERIMUX-TERM-CS-16Connect the Serimux and Terminal to a Network MonitorSetup The Terminal Getting StartedF4- Comm Setup Menu Saving and Exiting SetupF2- Genrl Setup Menu Connect to the SerimuxStartup- Accessible host list Terminal Control Using the Serimux Console SwitchDefault keypad PIN number is Serial ControlAdministrator Controls Login as the administratorPort List Port list displays the status of all portsPort Settings Port settings menuSetting Description Value Stop Bit Port serial settingsData bit ParityXon or Xoff Characters Flow control CommandInter-character delay DTR line behaviorDisplay serial settings for different port number Modem settingsCopy Port Serial Settings Function KeystrokeDisplay modem settings for different port number Port data bufferClear Port data buffer User List User ListUser Settings User settings menuPort access Copy User SettingsOption Description Setting Description Value Advanced SettingsChange administrator password Local KeyPad PIN Defines the PIN number for LocalFirmware Function DescriptionLoad new firmware Save current firmware Serimux is waiting to save its firmware User Accessible host list screen User ControlsUser main menu User main menuLimited user accessible Port list Port List screen¾ Accessible host list User Terse modeTerse mode commands ¾ Connect to port ¾ Port infoSystem Reset button ¾ Verbose mode¾ User Logout Firmware Upgrade Firmware upload windowLast confirmation before firmware update Functions of the Keypad Login the administratorKeypad Control Action from Keypad Reaction of SerimuxLogin a user to the administrator main menu Login user to a portDisconnect and logout a user Connect 2 host portsAction from Keypad Reset Serimux Console Switch to default settings Disconnect 2 portsTo detach a modem Using the Terminal How To Setup The TerminalF1- Disp Setup Menu F2- Genrl Setup MenuChanging The Terminal Operating Parameters F3- Keybd Setup Menu F4- Comm Setup MenuPrinter F6-Tabs SET-UP Menu F5- Misc Setup MenuF7- FKeys SET-UP Definition Setup Menu Printer RCV ON/OFFF10- Colr1 Set-up Menu F9- Lan Setup MenuF8- Ansbk SET-UP Menu Programmable KeysAttribute = Bold/Blink Color Association = OFF/ON Color Setup MenuF11- Colr2 Set-up Menu OptionColor Palettes Palette Display Attribute Foreground Color Background ColorColor Palettes Contd Local Keyboard Commands Command Enhanced PCSame Terminal Command GuideCommands Supported in Ascii Personalities WyseStop parity word Native Mode WyseSelect bell volume Key/fkey DELESC . cursor1 Sequence DELKey/fkey Sequence Sequence DEL Message CRFcolor ESC a mf attrAttr Bcolor mapCol Line colCcc C Editing Contd Clearing DataSending data Set Print FunctionsCharacter Sets Pp bb...bbVariable Values for Commands Variable Values for Commands Contd Definition LengthLine/Column Max Maximum SpeedPalette Color Pallette Bell VolumeFunction Key Parity BitsAnsi Command Guide 1 VT100, VT220 and Console Ansi Command GuideSupported VT100,VT220 and Console Ansi Commands ESC Ps final Supported VT100, VT220 and Console Ansi Commands, ContdCharacter Set Selection Label assignedValues for Ps above Supported VT100, VT220 and Console Ansi Commands ContdFinal character Character AttributeValues for Psn in table on Editing FunctionsSee tables below an on next page for values Kc/hc ST String Clear Key LockShifted function key Key Value Redefine keys with stringUnshifted function key Values of Fn for Numeric Keypad keysAuxiliary Keypad Modes More Terminal Control CommandsTerminal Resets Transmission/Printer ControlSee table below for values of Ps 2 VT52 Command GuideCommand VT52 Keyboard LanguageUsing Printer Server via Ethernet Connection Basic SetupSetup for LPD Setup for Tftp LPD printingTftp Printing Hardware Specifications Terminal Hardware Specifications SerimuxHardware Information Serial Port Cabling Pin assignment at Wire Color Standard End Crossed EndCPU-to-RACKMUX Ethernet Crossover Cable Serial Port PinoutsRJ45 Signal Cable AdaptersDB25F 3 4 Terminal Connector Pin AssignmentsSUB-D Female connector Mating face of an RJ45 FemaleAppendix B Serimux User and Administrator Characteristics Appendix a Serimux Port CharacteristicsDescription Acceptable Value Default Value AdministratorWarranty Information Index