Quatech DSE-410D RS-485 Mode, Selecting Internal RS-485 Bias Resistors, RS-422 Mode, RS-232 Mode

Page 15

RS-485 Mode

The RS-485 mode supports the Transmit and Receive Channels using 2-wire half- duplex operation. The data lines are differential with the Data B line positive relative to Data A in the Mark state. Ground provides a common mode reference. Refer to the Pin-out table for connections.

Selecting Internal RS-485 Bias Resistors

You can select RS-485 Receiver Biasing from the DSE-410D if your network doesn’t supply any. Remove the two side cover screws, slide the cover off, then set the two bias jumpers (shown open) to enable biasing (shorting).

RS-422 Mode

The RS-422 mode supports 4 channels with full duplex operation for Receive, Transmit, RTS (Request To Send) and CTS (Clear To Send). The data lines are in differential pairs with the B lines positive relative to the A lines. Ground provides a common mode reference. To use handshaking, Flow Control must be set to RTS/CTS during configuration. Refer to the Pin-out table for connections.

RS-232 Mode

The RS-232 mode supports eight channels plus Signal Ground and is configured as DTE, like a computer. Signals are single-ended and referenced to Ground. To use handshaking, Flow Control must be set to RTS/CTS during Configuration. Refer to the Pin-out table for connections.

Default Setting

Use this mode to reset the original factory default settings when powered on.

Document Number: 940-0186-100 DSE-410D Owner’s Manual

9

Quatech, Inc. - 5675 Hudson Industrial Parkway, Hudson, OH 44236 – 330.655.9000

http://www.quatech.com

Image 15
Contents World Headquarters Model DSE-410DPage Table of Contents Server Name Password Searching LAN for DSE-410DMAC Address Installing Virtual Com Port Page Introduction FeaturesDirect IP Mode Virtual COM ModeCommunication Modes Quick Start Heart Beat ConnectionDhcp Default DSE-410D SettingsSpecifications Dimensions Optional AccessoriesConfiguration Options Light Indication Side View when vertically mountedHardware Ethernet ConnectionTop View Power ConnectionReset Button Mode Switches DSE-410D Server PortDefault Setting RS-485 ModeRS-422 Mode RS-232 ModeSerial Connections RS-232 Connections RS-422 Connections RS-485 Connections Page Install Quatech DSE-410D Software Page Page Page Searching LAN for DSE-410D Using DSE-410D ManagerSearching Server Firmware UpgradeVirtual COM Configuration Uninstall Virtual COMServer Properties Screen ProtocolCOM Name StatusNext chapter Server Properties Configuration Password Server NameIP Address, Netmask, and Gateway Properties Baud Rate Set for each port Link Status Shown in Telnet or Console mode onlyMAC Address Server Serial Port Select 1 orTCP/UDP Port Set for each port Connection Mode Set for each portFlow Control Set for each port TCP/UDP Protocol Set for each portUpdate Page Installing Virtual Com Port Page Page Use Device Manager to View New Ports Page Page Removing a Virtual Com Port Removing the Virtual COM Port using Device Manager Page Page Using Virtual COM or Serial Connections Upgrade ModePage Page Page Console Mode Setup Page Appendix a RS-232, RS-422 Loopback Connections Page DB9M Appendix B RS-232 ConnectionsRS-232 Connections cont’d Appendix C RS-422 Connections Signal Name Direction PinRS-422 Connections cont’d Appendix D RS-485 Connections Page Appendix E Warranty Date of Purchase Model Number