Lamp Run Time

When the total run time of the lamp is 970 hours or more, the following warning message will be displayed for 1 minute. This warning message will be repeated every 30 minutes. Press EXIT to remove the message before the minute is over.

When the total run time of the lamp is 1000 hours or more, the following warning message, with the exact run time is displayed on the screen.

Lamp run time is 1000 hours. Operating the lamp longer than 1000 hours may damage the projector. Please replace the lamp.

When OK (ENTER) is pressed to go on, the warning will be repeated every 30 min.

The total lifetime of the lamp for a safe operation is 1000 hours max. Do not use it longer. Always replace with a same type of lamp. Call a BARCO authorized service technician for lamp replacement.

Warning : Using a lamp for more than 1000 hours is dangerous as the lamp could explode.

Lamp run time 980 h

WARNING

Lamp run time is 1000 hours Operating the lamp longer

than 1000 hours may damage the projector.

Please replace the lamp

<ENTER> to continue

Switching to Stand-by.

When the projector is running and you want to go to stand-by, press the stand-by key.

Input Connections.

The projector has three fixed and two modular input facilities. The modular input slots (slot 3 and 4) can be filled up with the following modules :

Video, S-video input

order no. : R9827900

RGBS/RGsB analog input

order no. : R9827910

RGB3S/RG3sB input

order no. : R9827920

Component Video

order no. : R9827930

The sequence of insertion has no importance. Duplicated inputs can be used.

Note : When using a RCVDS05 or VS05, the input configu- ration of the projector must be as follows:

Slot 1 : not used

Slot 2 : RGB and Component video input

Slot 3 : Video input module

Slot 4 : not used

When using a RCVDS05, it is recommended to use a 5-cable output module in the RCVDS. The outputs of this module has to be connected to slot 2 of the projector.

To switch the projector in the 5-cable mode see chapter 'Installation mode'.

Input module insertion into the projector :

-Power down the projector and disconnect the power cord from the wall outlet.

-Remove the dummy plate covering the chosen input slot by turning out both screws.

-Slide the input module in the free slot. Insure the module is seated correctly in the guide grooves.

-Press on both handles of the input module until the module plug seats in the connector of the projector.

-Secure the input module by tightening both retaining screws.

5-2

Switching Off

To switch off:

-First press STANDBY key and let the projector cool down until the fans stop blowing, or at least 15 min.

-Switch off the projector with the power switch.

WARNING : When switching to standby, never restart the projector (hot restrike) within the first 3 minutes to avoid damage to the lamp.

0 I

 

 

 

 

 

 

DIA GNOSTICS

 

 

 

IR-ACKNOWLEDGED

CODE

IR-RECEIVER

RS232 OUT

RS 232 IN

REMOTE

 

 

 

 

IR-RECEIVED

 

 

 

 

 

 

98 27910

-Reconnect the power cord to the wall outlet and switch on the projector.

The new installed module can be selected with the digit buttons on the RCU or the local keypad.

5976052 BARCOREALITY 9300 070999

Image 18
Contents Reality 9300 DLC Federal communication commission FCC statement Barco Projection Systems Date Art. No 070999 R5976052Table of Contents Unpacking and Dimensions Projector dimensionsUnpacking Battery installation in the RCU Installation Guidelines Componentvideo Where to install the projector?How to install a projection lens? Separate SyncFront Panel Terminology Control Panel Terminology a. Local keypadRemote control 175RCU Location and Functions of Control Configuration OSD Color ConfigurationInstallation FRONT/TABLE@-40 Projector Mode Communication Port Green Operation Installation Set Up Connections AC Power mains cord connectionSwitching on FusesLamp Run Time Switching to Stand-bySwitching Off Input ConnectionsInput Slots Peripheral Convergence Configuration Input SlotsFixed RGB analog input slot RGB-SOGRgbhv Rgbs Peripheral Convergence ConfigurationFixed 5-Input Slot slot VideoVideo/S-video Input Module 269,2VIDEO,1387RGB Analog Input Module Component Input Module 2032117B-Y S9,2,1387Input Slots 16HSDRUP UD \ RGB3S / RG3sB Input ModuleSerial Digital Input slot 6HSDUDWH--6\QFV-VHOHFWLRQ\QFRQJUHHQConnecting a VS05 to the projector Set up of the Baud Rate for Communication with a ComputerConnecting a Rcvds 05 to the projector Connecting an IR Remote Receiver 800 to the projectorHow to Use the RCU? ControllingRCU Projector AddressPicture Controls with Direct Access How to Display a Projector Address?How to Program an Address into the RCU? Pause keyRandom Access Installation Service Start UP of the Adjustment ModeAdjustment Mode PasswordRandom Access Adjustment Mode Starting up the Random Access Adjustment ModeFile Service Edit File File ServiceLoad File LoadHow to find the correct values for the displayed item? Read AmdsOptions Rename Field PolarityRename Copy CopyDelete DeleteFile Options Picture TuningColor Temperature File SortGamma GammaDecoding EBU/IRE Decoding EBUInput Balance Dynamic Color DepthNoise Reduction Dynamic Color DepthGeometry ShiftSize Side Keystone Side KeystoneBlanking BlankingOptions Blanking TOP Bottom Left RightShift Size Side Keystone Blanking Starting up the Installation Mode Input SlotsPeripheral Output module selection How to AdjustTroubleshooting Infrared CommunicationBlue on Green convergence Green FocusingGreen to Midposition EnterRed on Green convergence HatchAbout Moca No Signal BLACK/BLUE OSD color On-Screen DisplayInternal Patterns Service Mode Starting up the Service ModeService Identification Software versionIdentification How to change the password ? Change PasswordHow to enable or disable the password function ? Service IdentificationChange Projector Address Reset Lamp RuntimeChange Language Change Baudrate PCLamp Drive Mode Lamp Run Time HistoryBarco logo Uniformity Panel AdjustmentsPreset Input Balance I2C diagnosisStandard Source SET UP Files SUNXGA60 SUNEWS67SUNEWS76 SUNXGA70Cleaning procedure for HD1.5-31 lens Focusing the lensLens Cleaning Procedure LensesLenses Projector without any 800 peripheral connected Projector with a 800 peripheral connectedSource numbers 90 Source numbers 81 13875&966285&6