Meridian America D-ILA 1080MF1 Indicator Display Table, Top panel indicators, Lamp replacement

Page 13

Indicator Display Table

The projector employs different patterns of indicator illumination to indicate its various operational states, as shown by the tables below.

Top panel indicators

 

 

Indicator

 

 

 

Description

 

 

 

 

 

 

STAND BY

OPERATE

LAMP

TEMP

FAN

HIDE

 

 

 

 

 

 

 

 

Light On

 

 

 

 

 

Unit is in standby mode

 

 

 

 

 

 

 

 

Light On

 

 

 

 

Unit is in operate mode (during projection)

 

 

 

 

 

 

 

 

 

 

 

 

 

When the video image is temporarily cleared

 

Light On

 

 

 

Light On

upon pressing the [HIDE] button during

 

 

 

 

 

 

projection

Blinking

 

 

 

 

 

Unit is in cool down mode

 

 

 

 

 

(when cooling lamp) - See note below

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Light On

Blinking

 

 

Lamp replacement should be performed soon

 

 

 

 

(Lamp usage time has exceeded 1900 hours)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Light On

 

Blinking

 

Lamp life has expired – replace lamp now

 

 

 

 

(Lamp usage time has exceeded 2000 hours)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit has been forced to enter cool-down mode

 

 

Light On

Blinking

Blinking

 

Until will not operate until lamp is replaced

 

 

 

Replace lamp immediately

 

 

 

 

 

 

 

 

 

 

 

 

(Lamp usage time has exceeded 2010 hours)

 

 

 

 

 

 

 

Control panel indicators

 

Indicator

Description

 

 

 

Rx

 

Tx

 

 

 

 

 

 

Light On

 

 

When this unit is receiving RS-232C data

 

 

 

 

 

 

Light On

When this unit is sending RS-232C data

 

 

 

 

Note: Cool Down Mode

After projection, the hot lamp goes through a 60-second cool-down process known as ‘cool down mode’. This mode is designed to prevent damage and deformation that heat from the heated lamp may cause to the internal com- ponents of the projector. It also minimises the chance of lamp breakage and shortened lamp life.

The cool down mode is indicated by the blink- ing Standby indicator. When in the cool down mode, the OPERATE ON button is disabled.

After the cool down process is completed, the unit will automatically switch into standby mode.

CAUTION:

When in the cool-down mode, do not pull out the plug from the power socket. Also, do not block the air inlets/ exhaust vents by standing this unit on its end or laying it on its side.

Lamp replacement

The timing and procedure for lamp replace- ment is discussed on page 27 et seq.

13

Image 13
Contents ILA 1080MF1 For Customer use FCC Information U.S.A. only Safety precautionsMachine Noise Information Germany only Product If in DOUBT, Consult a Competent Electrician Information for Users on Disposal of Old Equipment EU Only Maintenance ProceduresEuropean Union Other Countries outside the European UnionPage Contents Accessories Controls & Features Service Connector AC Power Input SocketRear & Right Side Handling the Control Panel CoverControl Panel Rx/Tx IndicatorsMenu Button Exit ButtonStandby Indicator IndicatorsOperate Indicator Temp IndicatorTop panel indicators Indicator Display TableControl panel indicators Lamp replacementProjector/Processor Select buttons Remote ControlOn Button OFF ButtonLight Button Test Button main labelZoom Tele/Wide Buttons main labels 8 Installing the Projector View from the side Projector and Screen InstallationView from Above Wide T Tele Screen Size and Projection DistanceAdjust the projection screen position Lens Shift SettingRe-fit the lens shift cover Projection screen position image according to shift levelConnecting a Video Processor Connecting to DevicesConnecting a computer or Home Automation System via RS232 Interfacing the ProjectorConnecting the Power Cable Supplied Turning off the power Adjusting zoom image size and focusApply Mains Power Precautions During UseMenu Structure Adjustments and Settings Using MenusAfter setting is completed, press the Exit button Accessing the Menus Press the Menu buttonMenu Operation Buttons Setup Menu Menu Position Pixel AdjustColor Temp Red, Green, BlueOptions Menu Menu Display Power SaveSleep Time RC232C bpsAbout Lamp Replacement When the lamp usage time reaches 2010 hoursReplacing the Lamp Loosen the screw and remove the lamp cover Lamp Replacement Procedure Remove the control panel coverLoosen the screws on the lamp unit and lift up the handle Pull out the lamp unitRe-attach the lamp cover and fasten the screw Tighten the screws of the lamp unit and fold down the handleCleaning and Replacing the Filter On-screen warning messages For Nos About warning indicatorsPower up TroubleshootingPinouts RS-232C Port Interface SocketsDVI-D Interface RS-232C External Control Numeric value External control command tableSpecial parameters Specifications All dimensions in millimetres Projector Dimensions