Function parameters for EJ
|
|
|
|
|
|
|
|
| To set “00000000” |
|
|
| |||||
|
| s |
| 68 |
|
| @ |
|
|
|
|
|
|
| s |
| A |
|
|
|
|
|
|
|
| *ABCDEFGH |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| |||||||||
* Item: |
|
|
| Selection: | Entry: | ||||||||||||
| A | Always enter 0. |
| (Fixed position) | 0 |
|
| ||||||||||
| B | Always enter 0. |
| (Fixed position) | 0 |
|
| ||||||||||
| C | Temporary EJ printing during transaction |
| Disallow | 0 |
|
| ||||||||||
|
|
|
|
|
| Allow* | 1 |
|
| ||||||||
| D | EJ printing and clearing EJ data when |
| No* | 0 |
|
| ||||||||||
|
| issuing general Z1 report |
| Yes | 1 |
|
| ||||||||||
| E | PGM mode operation records type |
| Details* | 0 |
|
| ||||||||||
|
|
|
|
|
| Header information only | 1 |
|
| ||||||||
| F | REG/MGR/VOID modes operation |
| Details* | 0 |
|
| ||||||||||
|
| records type |
| Total | 1 |
|
| ||||||||||
| G | Compressing printing for EJ data |
| No (normal size) | 0 |
|
| ||||||||||
|
|
|
|
|
| Yes (small size)* | 1 |
|
| ||||||||
| H | Action when EJ memory area is full |
| Continue | 0 |
|
| ||||||||||
|
|
|
|
|
| Warning (near full warning)* | 1 |
|
| ||||||||
|
|
|
|
|
| Lock (with near full warning) | 2 |
|
|
On the default setting, an asterisk is marked.
Temporary EJ printing during transaction
• If selecting “yes”, you can print journal data of a current transaction recorded in EJ memory by pressing the
Rkey during the transaction. To realize this function completely, the cash register is programmed to receipt printing and set Receipt ON/OFF function to OFF.
PGM mode operation records type
•For data of program reading operation, the header information only is printed. For X/Z reports, the header information only is printed.
(Receipt sample for Header Information only)
Action when EJ memory area is full
•By default, when the memory for EJ becomes nearly full, the cash register shows decimal points at the 8th and 9th positions of the display (EJ memory nearly full message), and the cash register keeps storing new data while erasing the oldest data. When “0” is selected, the cash register will not show EJ memory nearly full message. When “2” is selected, the cash register shows EJ memory nearly full message and when the memory gets full, the cash register locks the sales/data entry with a display of the memory full message
.” You can only issue an EJ report.
Key operation example |
|
s68 @
00100002 sA
46