Maintenance and Troubleshooting
The lamp should be replaced when it reaches the end of its life (typically 2000 hours), or sooner if a noticeable degradation in brightness occurs. Contact your Runco dealer to obtain a replacement lamp.
1. Turn off the projector and unplug the power cord.
Allow the projector to cool down for approximately 45 minutes prior to removing the lamp assembly for replacement.
2.Remove the two screws from the lamp cover.
3.Remove the lamp cover.
4. Remove the two lamp assembly mounting screws.
5.Grasp the lamp assembly handle and pull gently, removing the lamp module from the projector housing.
6. Install the new lamp module and replace the two screws you removed in Step 4.
5.1
Lamp Replacement
7.Replace the lamp cover at the top first and secure it with the two screws you removed in Step 2.
8.Turn on the power and select Reset Lamp Timer from the Set Up menu to reset the lamp timer (refer to Reset Lamp Timer on page 45).