TDK 750W HALF RACK technical manual Chapter, Specifications

Page 17

CHAPTER 2

SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.1 OUTPUT RATING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

 

GEN

6-100

 

8-90

12.5-60

 

20-38

 

30-25

40-19

 

 

60-12.5

80-9.5

 

100-7.5

 

150-5

300-2.5

600-1.3

 

1.Rated output voltage (*1)

 

V

6

 

8

12.5

 

20

 

30

40

 

 

60

80

 

100

 

150

300

600

 

2.Rated output current 750W (*2)

 

A

100

 

90

60

 

38

 

25

19

 

 

12.5

8.5

 

7.5

 

5

2.5

1.3

 

3.Rated output power 750W

 

W

600

 

720

750

 

760

 

750

760

 

 

750

760

 

750

 

750

750

780

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

 

GEN

6-200

 

8-180

12.5-120

 

20-76

 

30-50

40-38

 

50-30

 

60-25

80-19

 

100-15

 

150-10

300-5

600-2.6

 

1.Rated output voltage (*1)

 

V

6

 

8

12.5

 

20

 

30

40

 

50

 

60

80

 

100

 

150

300

600

 

2.Rated Output Current 1500W (*2)

 

A

200

 

180

120

 

76

 

50

38

 

30

 

25

19

 

15

 

10

5

2.6

 

3.Rated output power 1500W

 

W

1200

 

1440

1500

 

1520

 

1500

1520

 

1500

 

1500

1520

 

1500

 

1500

1500

1560

 

2.2 INPUT CHARACTERISTICS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

6

 

8

12.5

 

20

 

30

40

 

50

 

60

80

 

100

 

150

300

600

 

1.

Input voltage/freq. (*3)

 

85~265Vac

continuous,

47-63Hz, single phase.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Input current (at 100/200Vac)

 

A

10.5/5 for 750W model, 21/11 for 1500W models.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Power Factor

 

0.99@100/200Vac, rated output power.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

750W models Efficiency (*4)

 

%

76/78

 

77/80

81/84

 

82/85

 

82/85

83/87

 

83/87

 

83/87

83/87

 

83/87

 

83/87

83/87

83/87

 

5.

1500W models Efficiency (*4)

 

%

77/79

 

78/81

82/85

 

83/86

 

83/86

84/88

 

84/88

 

84/88

84/88

 

84/88

 

84/88

84/88

84/88

 

6.

Inrush current at 100/200V

 

A

Less than

25A for 750W models, 50A for 1500W models.

 

 

 

 

 

 

 

 

 

 

 

 

 

2.3 CONSTANT VOLTAGE MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

6

 

8

12.5

 

20

 

30

40

 

50

 

60

80

 

100

 

150

300

600

 

1.

Max.Line regulation (*5)

 

0.01% of

rated output

voltage +2mV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Max.Load regulation (*6)

 

0.01% of rated output voltage +2mV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Ripple and noise (p-p,20MHz) (*10)

mV

60

 

60

60

 

60

 

60

60

 

60

 

60

80

 

80

 

100

150

300

 

4.

Ripple r.m.s., 5Hz~1MHz (*10)

 

mV

8

 

8

8

 

8

 

8

8

 

8

 

8

8

 

8

 

10

25

60

 

5.

Temperature coefficient

 

PPM/°C

100PPM/°C

of rated output voltage, following 30 min utes warm up

 

 

 

 

 

 

 

 

 

 

 

 

6.

Temperature drift

 

0.05% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.

 

 

 

 

 

 

7.

Rem. Sense compensation/wire

 

V

1

 

1

1

 

1

 

1.5

2

 

2

 

3

4

 

5

 

5

5

5

 

8.

Up-prog. Response time 0~Vomax (*9)

mS

 

 

 

 

 

80

 

 

 

 

 

 

 

 

 

150

 

 

250

 

9.

Down-prog. Response time: Full load

mS

10

 

 

50

 

 

 

 

 

80

 

 

 

 

150

 

 

250

 

 

 

No load

 

500

 

600

700

 

800

 

900

1000

 

1100

 

1100

1200

 

1500

 

2000

2500

4000

 

10. Transient response time

 

mS

Time for the output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated

 

 

 

 

 

 

 

 

 

 

output current.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output set-point: 10~100%.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Less than 1mS for models up to and including 100V; 2mS for models above 100V.

 

 

 

 

 

 

 

 

11. Hold-up time

 

mS

More than 20mS, 100Vac, rated output power.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.4 CONSTANT CURRENT MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

6

 

8

12.5

 

20

 

30

40

 

50

 

60

80

 

100

 

150

300

600

 

1.

Max.line regulation (*5)

 

0.01% of

rated output

voltage +2mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Max.load regulation (*7)

 

0.02% of rated output current +5mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Ripple r.m.s. 5Hz~1MHz.750W (*8)

mA

200

 

180

120

 

76

 

63

48

 

 

38

29

 

23

 

18

13

8

 

 

1500W (*8)

mA

400

 

360

240

 

152

 

125

95

 

75

 

75

57

 

45

 

35

25

12

 

4.

Temperature coefficient

 

PPM/°C

100PPM/°C

from rated

output current,

following

30 m inutes

warm-up.

 

 

 

 

 

 

 

 

 

 

 

5.

Temperature drift

 

0.05% of rated lout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.

 

 

 

 

 

 

2.5 ANALOG PROGRAMMING AND MONITORING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Vout voltage programming

 

0~100%, 0~5V or 0~10V, user select. Accuracy and linearity; +/-0.5% of rated Vout.

 

 

 

 

 

 

 

 

2.

Iout voltage programming

 

0~100%, 0~5V or 0~10V, user select. Accuracy and linearity; +/-1% of rated Iout.

 

 

 

 

 

 

 

 

 

3.

Vout resistor progrmming

 

0~100%, 0~5/10Kohm full scale, user select. Accuracy and linearity: +/-1% of rated Vout.

 

 

 

 

 

 

 

 

4.

Iout resistor programming

 

0~100%, 0~5/10Kohm full scale, user select. Accuracy and linearity: +/-1.5% of rated Iout.

 

 

 

 

 

 

 

 

5.

On/off control

 

By electrical Voltage: 0~0.6V/2~15V or dry contact, user selectable logic.

 

 

 

 

 

 

 

 

 

6.

Output current monitor

 

0~5V or 0~10V, user selectable. Accuracy: 1%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.

Output voltage monitor

 

0~5V or 0~10V, user selectable. Accuracy: 1%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.

Power supply OK signal

 

4~5V-OK, 0V-Fail, 500ohm series resistance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9.

Parallel operation

 

Possible, up to 4 units in master/slave mode with single wire current balance connection.

 

 

 

 

 

 

 

 

10. Series operation

 

Possible (with external diodes), up to 2 units.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11. CV/CC inicator

 

CV: TTL high (4~5V), source current: 10mA, CC: TTL low (0-0.6V). Sink current: 10mA .

 

 

 

 

 

 

 

 

12. Enable/Disable

 

Dry contact. Open: off, Short: on. Max. voltage at Enable/Disable in: 6V.

 

 

 

 

 

 

 

 

 

13. Local/Remote analog control

 

By electrical signal or Open/Short: 0~0.6V or short: Remote, 4~5V or open: Local.

 

 

 

 

 

 

 

 

 

14. Local/remote analog indicator

 

Open collector. Local: Open, Remote: On. Maximum voltage: 30V, maximum sink current: 5mA.

 

 

 

 

 

9

83-507-5002 Rev. B

Image 17
Contents Genesystm 750W Half Rack Page Page Genesys Manual Supplement Table of Contents Front and Rear Panel Controls and CONNECTORS………... ……… ……… Isolated Analog Progamming Option ……………………………..…… Warranty Safety Instructions Safety Instructions SICHERHEITS-INSTALLATIONS Anweisungen Umweltbedingungen Sicherheits-und WarnsymboleAnderungen and Bauteileersatz General Information Features and optionsIntroduction General DescriptionControl via the serial communication port Multiple output power systemAnalog voltage programming and monitoring Parallel operationAccessories Chapter SpecificationsFront Panel Supplemental Characteristics Genesystm Genh 750W Power Supplies Outline Drawings General InstallationPreparation for USE Initial InspectionsRack Mounting Single unit installationLOCATION, Mounting and Cooling AC Input Power ConnectionAC Source Requirements GENH/RM Rack Mounting outline drawingsAC Input Connector TURN-ON Checkout ProcedureAC Input Cord GeneralConstant Current Check Constant Voltage CheckOVP Check UVL CheckConnecting the Load AWG Wire terminationInductive loads Noise and Impedance EffectsMaking the load connections 6V to 60V ModelsBus-bars shield mounting 80V to 600V Models 83-507-5002 Rev. B Connecting multiple loads, radial distribution method Connecting single loads, local sensing defaultConnecting single loads, remote sensing Grounding outputs Multiple load connection with distribution terminalsOutput Terminal Grounding Sense wiringLocal and Remote Sensing Local sensingRemote sensing 10.4 J2 sense connector technical informationVoltage Front and Rear Panel Controls and ConnectorsFront Panel Controls and Indicators Auxiliary Function Rear panel connections and controls Number Description Rear Panel Connections and Controls1 SW1 position function Rear Panel SW1 Setup SwitchMaking J1 connections Rear Panel J1 Programming and Monitoring ConnectorResetting the SW1 switch 83-507-5002 Rev. B Enain SignalIfcom LocalConstant Current Mode Constant Voltage ModeLocal Operation Standard OperationResetting the OVP circuit Setting the OVP levelOver Voltage Protection OVP Automatic CrossoverUnder Voltage Limit UVL Output SHUT-OFF SO Control VIA Rear Panel J1 ConnectorFoldback Protection Output ON/OFF ControlCV/CC Signal ENABLE/DISABLE Control VIA Rear Panel J1 ConnectorOver Temperature Protecton OTP Psok SignalLast Setting Memory SAFE-START and AUTO-RESTART ModesSeries connection for increased output voltage Series OperationSeries connection for positive/negative output voltages Series connection for positive and negative output voltageSetting up the Slave units Setting up the Master unitParallel Operation Basic parallel operationSetting Foldback protection Setting Over Voltage protectionAdvanced parallel configuration Setting the units as Master or SlaveTo release units from Slave mode Master and Slave units default operationCurrent display accuracy AST OFF OUT OFFFront Panel Locking DAISY-CHAIN ConnectionLocked front panel Unlocked front panelLOCAL/REMOTE Analog Indication Remote Analog ProgrammingRemote voltage programming connection DownRemote resistive programming Resisitive Programming of Output Voltage and Current LimitRemote Monitoring of Output Voltage and Current Configuration RS232 & RS485 Remote ControlFront panel in Remote mode Rear Panel RS232/RS485 Connector6 RS232/RS485 port in Local mode MD Mode enable Serial communication mode MD Mode DescriptionMD Mode SRQ MD Mode SRQ RetransmissionSingle power supply Connecting Power Supplies to RS232 or RS485 BUSCommunication Interface Protocol Command SET Description Error MessagesOutput Control Commands Initialization Control CommandsID Control Commands Filter DVC?FILTER? OUT?Global Output Commands Enable MD Mode MD Mode Option Required Single Byte CommandsDisable SRQ retransmission MD Mode Option Required Enable SRQ retransmission MD Mode Option RequiredRetransmit Last Message Addressed commands with response Read registersPrint Power On Time Re-enable SRQ with out reading/clearing the Seve Register Test if MD Mode is InstalledAddressed commands without response Acknowledge SRQ 110x Status Control Commands STATUS, Error and SRQ RegistersTXD Conditional RegistersBIT Service Request Enable and Event RegistersFault Event Register Fault Enable RegisterStatus Event Register Status Enable RegisterCommunication Test Power supply set-upSerial Communication Test SET-UP Isolated Analog Programming Option Specifications1 0-5V/0-10V Option PN IS510 PPM/CIsolated Programming & Monitoring Connector Setup and Operating Instructions Maintenance OUP Fuse Rating