SYMPTOM

CHECK

ACTION

REF

Output is present

Is the power supply

Check if the positive or

3.9.6

momentarily but shuts off

configured to Remote

negative load wire is loose.

3.9.8

quickly.The display indicates

sense?

 

 

“OUP”.

 

 

 

Output Voltage will not

Is the unit in constant

Check Output Current

5.2.1

adjust. Front panel CC LED

current mode?

setting and load current.

5.2.2

is On.

 

 

 

Output Voltage will not

Check if output voltage is

Set OVP or UVL so they will

5.3

adjust Front panel CV Led is

adjusted above OVP

not limit the output.

5.4

On.

setting or below UVL

 

 

 

setting.

 

 

Output Current will not

Is the unit in constant

Check Output Current and

5.2

adjust. Front panel CV LED

voltage mode?

voltage setting

 

is on.

 

 

 

Large ripple present in

Is the power supply in

Check load and sense wires

3.9.4

output.

remote sense?

connection for noise and

3.9.8

 

Is the voltage drop on the

impedance effects. Minimize

 

 

load wire high?

the drop on the load wires.

 

No output. Display indicates

Overvoltage Protection

Turn off the AC power

5.3

“OUP”

circuit is tripped.

switch. Check load

 

 

 

connections. If Analog

 

 

 

Programming is used, check

 

 

 

if the OVP is set lower than

 

 

 

the output.

 

No output. Front panel

Display indicates “ENA”

Check rear panel J1

5.8

ALARM LED is blinking.

 

ENABLE connection.

 

 

 

Setup switch SW1 setting.

4.4

 

Display indicates “SO”

Check rear panel J1 Output

5.7

 

 

Shut-Off connection.

 

 

Display indicates “OTP”

Check if air intake or

 

 

 

exhaust are blocked. Check

 

 

 

if the unit is installed

 

 

 

adjacent to heat generating

 

 

 

equipment.

 

 

Display indicates “Fb”

Check Foldback setting and

5.5

 

 

load current.

 

Poor Load regulation.

Are sensing wires

Connect the sense wires

3.9.8

Front panel CV LED is on.

connected properly?

according to User’s Manual

 

 

 

instructions.

 

The front panel controls are

Is the power supply in

Turn Off the AC power and

7.2.5

non-functional.

Local-Lockout mode?

wait until the display turns

 

 

 

off. Turn on the AC power

 

 

 

and press front panel

 

 

 

REM/LOC button.

 

73

83-507-5002 Rev. B

Image 81
Contents Genesystm 750W Half Rack Page Page Genesys Manual Supplement Table of Contents Front and Rear Panel Controls and CONNECTORS………... ……… ……… Isolated Analog Progamming Option ……………………………..…… Warranty Safety Instructions Safety Instructions SICHERHEITS-INSTALLATIONS Anweisungen Sicherheits-und Warnsymbole Anderungen and BauteileersatzUmweltbedingungen General Information Features and optionsIntroduction General DescriptionControl via the serial communication port Multiple output power systemAnalog voltage programming and monitoring Parallel operationAccessories Chapter SpecificationsFront Panel Supplemental Characteristics Genesystm Genh 750W Power Supplies Outline Drawings General InstallationPreparation for USE Initial InspectionsRack Mounting Single unit installationLOCATION, Mounting and Cooling AC Input Power ConnectionAC Source Requirements GENH/RM Rack Mounting outline drawingsAC Input Connector TURN-ON Checkout ProcedureAC Input Cord GeneralConstant Current Check Constant Voltage CheckOVP Check UVL CheckConnecting the Load AWG Wire terminationInductive loads Noise and Impedance EffectsMaking the load connections 6V to 60V ModelsBus-bars shield mounting 80V to 600V Models 83-507-5002 Rev. B Connecting single loads, local sensing default Connecting single loads, remote sensingConnecting multiple loads, radial distribution method Grounding outputs Multiple load connection with distribution terminalsOutput Terminal Grounding Sense wiringLocal and Remote Sensing Local sensingRemote sensing 10.4 J2 sense connector technical informationFront and Rear Panel Controls and Connectors Front Panel Controls and IndicatorsVoltage Auxiliary Function Rear panel connections and controls Number Description Rear Panel Connections and Controls1 SW1 position function Rear Panel SW1 Setup SwitchRear Panel J1 Programming and Monitoring Connector Resetting the SW1 switchMaking J1 connections 83-507-5002 Rev. B Enain SignalIfcom LocalConstant Current Mode Constant Voltage ModeLocal Operation Standard OperationResetting the OVP circuit Setting the OVP levelOver Voltage Protection OVP Automatic CrossoverUnder Voltage Limit UVL Output SHUT-OFF SO Control VIA Rear Panel J1 ConnectorFoldback Protection Output ON/OFF ControlCV/CC Signal ENABLE/DISABLE Control VIA Rear Panel J1 ConnectorOver Temperature Protecton OTP Psok SignalLast Setting Memory SAFE-START and AUTO-RESTART ModesSeries connection for increased output voltage Series OperationSeries connection for positive/negative output voltages Series connection for positive and negative output voltageSetting up the Slave units Setting up the Master unitParallel Operation Basic parallel operationSetting Foldback protection Setting Over Voltage protectionAdvanced parallel configuration Setting the units as Master or SlaveTo release units from Slave mode Master and Slave units default operationCurrent display accuracy AST OFF OUT OFFFront Panel Locking DAISY-CHAIN ConnectionLocked front panel Unlocked front panelLOCAL/REMOTE Analog Indication Remote Analog ProgrammingRemote voltage programming connection DownRemote resistive programming Resisitive Programming of Output Voltage and Current LimitRemote Monitoring of Output Voltage and Current Configuration RS232 & RS485 Remote ControlRear Panel RS232/RS485 Connector 6 RS232/RS485 port in Local modeFront panel in Remote mode MD Mode enable Serial communication mode MD Mode DescriptionMD Mode SRQ MD Mode SRQ RetransmissionSingle power supply Connecting Power Supplies to RS232 or RS485 BUSCommunication Interface Protocol Command SET Description Error MessagesInitialization Control Commands ID Control CommandsOutput Control Commands Filter DVC?FILTER? OUT?Global Output Commands Enable MD Mode MD Mode Option Required Single Byte CommandsDisable SRQ retransmission MD Mode Option Required Enable SRQ retransmission MD Mode Option RequiredAddressed commands with response Read registers Print Power On TimeRetransmit Last Message Test if MD Mode is Installed Addressed commands without response Acknowledge SRQRe-enable SRQ with out reading/clearing the Seve Register 110x Status Control Commands STATUS, Error and SRQ RegistersTXD Conditional RegistersBIT Service Request Enable and Event RegistersFault Event Register Fault Enable RegisterStatus Event Register Status Enable RegisterPower supply set-up Serial Communication Test SET-UPCommunication Test Isolated Analog Programming Option Specifications1 0-5V/0-10V Option PN IS510 PPM/CIsolated Programming & Monitoring Connector Setup and Operating Instructions Maintenance OUP Fuse Rating