TDK 750W HALF RACK Enain, Ifcom, Local, Remote, Vpgm, Ipgm, Vmon, Com, Cv/Cc, Enaout, Psok, Imon

Page 41

 

 

 

 

 

 

 

 

 

 

 

Same ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

as P/S negative

 

 

 

 

 

 

 

 

 

 

 

 

VMON

 

 

 

 

 

 

 

 

 

 

 

sense (-S)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM

 

 

 

 

 

 

 

 

 

 

 

 

 

IPGM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CV/CC

 

 

 

 

 

 

 

 

 

 

 

 

 

VPGM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOC/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

12

11

10

9

8

 

 

7

6

 

5

4

3

2

1

25

24

23

22

21

20

19

18

17

16

15

14

 

 

IF_COM IF_COM ENA_IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

 

 

 

 

 

Isolated from

 

ENA_OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IMON

 

 

 

 

 

 

 

PS outputs,

 

 

SO

 

 

IPGM_RTN

 

 

 

 

 

 

 

 

same ground

 

 

 

PS_OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VPGM_RTN

 

 

 

 

 

 

 

as RS232/RS485

 

 

 

 

 

 

 

 

 

 

 

 

 

LOC/REM SIGNAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 4-4: J1 Connector terminals and functions

 

Table 4-4: J1 connector terminals and functions

 

 

 

 

 

 

J1

Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

contact

name

 

 

 

 

 

 

 

 

 

 

 

Function

 

Reference

J1-1

ENA_IN

 

Enable/Disable the power supply output by dry-contact

Sec. 5.8

 

 

 

(short/open) with ENA_OUT.

 

 

J1-2

IF_COM

 

Isolated Interface Common. Return for the SO control,

Sec.5.7,

J1-3

 

 

PS_OK signal and for the optional IEEE interface.

5.10

J1-4i7

N/C

 

No Connection

 

 

 

 

 

 

J1-8

LOCAL/

 

Input for selecting between Local or Remote analog pro-

Sec. 6.2

 

REMOTE

 

gramming of Output Voltage and Output Current.

 

J1-9

VPGM

 

Input for remote analog voltage/resistance programming

Sec.

 

 

 

of the Output Voltage.

 

6.1i6.4

J1-10

IPGM

 

Input for remote analog voltage/resistance programming

Sec.

 

 

 

of the Output Current.

 

6.1i6.4

J1-11

VMON

 

Output for monitoring the power supply Output Voltage.

Sec. 6.6

J1-12

COM

 

Control Common. Return for VMON, IMON, CV/CC, LOC/REM.

 

 

 

 

Connected internally to the negative sense potential (-S).

 

J1-13

CV/CC

 

Output for Constant-Voltage/Constant-Current mode

Sec. 5.9

 

 

 

indication.

 

 

 

 

 

 

J1-14

ENA_OUT

 

Enable/Disable the power supply output by dry-contact

Sec. 5.8

 

 

 

(short/open) with ENA_IN.

 

 

J1-15

SO

 

Input for Shut-Off control of the power supply output.

Sec. 5.7

J1-16

PS_OK

 

Output for indication of the power supply status.

Sec. 5.10

J1-17i20

N/C

 

No Connection.

 

 

 

 

 

 

J1-21

LOC/REM

 

Output for indicating if the unit is in Local or Remote ana-

Sec. 6.3

 

SIGNAL

 

log programming mode.

 

 

J1-22

VPGM_RTN

 

Return for VPGM input. Connected internally to the “-S”.

Sec. 6.1,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.4, 6.5

J1-23

IPGM_RTN

 

Return for IPGM input. Connected internally to the “-S”.

Sec. 6.1,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.4, 6.5

J1-24

IMON

 

Output for monitoring the power supply Output Current.

Sec. 6.6

J1-25

P

 

Output for current balance in parallel operation.

 

33

83-507-5002 Rev. B

Image 41
Contents Genesystm 750W Half Rack Page Page Genesys Manual Supplement Table of Contents Front and Rear Panel Controls and CONNECTORS………... ……… ……… Isolated Analog Progamming Option ……………………………..…… Warranty Safety Instructions Safety Instructions SICHERHEITS-INSTALLATIONS Anweisungen Umweltbedingungen Sicherheits-und WarnsymboleAnderungen and Bauteileersatz General Information Features and optionsIntroduction General DescriptionControl via the serial communication port Multiple output power systemAnalog voltage programming and monitoring Parallel operationAccessories Chapter SpecificationsFront Panel Supplemental Characteristics Genesystm Genh 750W Power Supplies Outline Drawings General InstallationPreparation for USE Initial InspectionsRack Mounting Single unit installationLOCATION, Mounting and Cooling AC Input Power ConnectionAC Source Requirements GENH/RM Rack Mounting outline drawingsAC Input Connector TURN-ON Checkout ProcedureAC Input Cord GeneralConstant Current Check Constant Voltage CheckOVP Check UVL CheckConnecting the Load AWG Wire terminationInductive loads Noise and Impedance EffectsMaking the load connections 6V to 60V ModelsBus-bars shield mounting 80V to 600V Models 83-507-5002 Rev. B Connecting multiple loads, radial distribution method Connecting single loads, local sensing defaultConnecting single loads, remote sensing Grounding outputs Multiple load connection with distribution terminalsOutput Terminal Grounding Sense wiringLocal and Remote Sensing Local sensingRemote sensing 10.4 J2 sense connector technical informationVoltage Front and Rear Panel Controls and ConnectorsFront Panel Controls and Indicators Auxiliary Function Rear panel connections and controls Number Description Rear Panel Connections and Controls1 SW1 position function Rear Panel SW1 Setup SwitchMaking J1 connections Rear Panel J1 Programming and Monitoring ConnectorResetting the SW1 switch 83-507-5002 Rev. B Enain SignalIfcom LocalConstant Current Mode Constant Voltage ModeLocal Operation Standard OperationResetting the OVP circuit Setting the OVP levelOver Voltage Protection OVP Automatic CrossoverUnder Voltage Limit UVL Output SHUT-OFF SO Control VIA Rear Panel J1 ConnectorFoldback Protection Output ON/OFF ControlCV/CC Signal ENABLE/DISABLE Control VIA Rear Panel J1 ConnectorOver Temperature Protecton OTP Psok SignalLast Setting Memory SAFE-START and AUTO-RESTART ModesSeries connection for increased output voltage Series OperationSeries connection for positive/negative output voltages Series connection for positive and negative output voltageSetting up the Slave units Setting up the Master unitParallel Operation Basic parallel operationSetting Foldback protection Setting Over Voltage protectionAdvanced parallel configuration Setting the units as Master or SlaveTo release units from Slave mode Master and Slave units default operationCurrent display accuracy AST OFF OUT OFFFront Panel Locking DAISY-CHAIN ConnectionLocked front panel Unlocked front panelLOCAL/REMOTE Analog Indication Remote Analog ProgrammingRemote voltage programming connection DownRemote resistive programming Resisitive Programming of Output Voltage and Current LimitRemote Monitoring of Output Voltage and Current Configuration RS232 & RS485 Remote ControlFront panel in Remote mode Rear Panel RS232/RS485 Connector6 RS232/RS485 port in Local mode MD Mode enable Serial communication mode MD Mode DescriptionMD Mode SRQ MD Mode SRQ RetransmissionSingle power supply Connecting Power Supplies to RS232 or RS485 BUSCommunication Interface Protocol Command SET Description Error MessagesOutput Control Commands Initialization Control CommandsID Control Commands Filter DVC?FILTER? OUT?Global Output Commands Enable MD Mode MD Mode Option Required Single Byte CommandsDisable SRQ retransmission MD Mode Option Required Enable SRQ retransmission MD Mode Option RequiredRetransmit Last Message Addressed commands with response Read registersPrint Power On Time Re-enable SRQ with out reading/clearing the Seve Register Test if MD Mode is InstalledAddressed commands without response Acknowledge SRQ 110x Status Control Commands STATUS, Error and SRQ RegistersTXD Conditional RegistersBIT Service Request Enable and Event RegistersFault Event Register Fault Enable RegisterStatus Event Register Status Enable RegisterCommunication Test Power supply set-upSerial Communication Test SET-UP Isolated Analog Programming Option Specifications1 0-5V/0-10V Option PN IS510 PPM/CIsolated Programming & Monitoring Connector Setup and Operating Instructions Maintenance OUP Fuse Rating