TDK 750W HALF RACK TURN-ON Checkout Procedure, AC Input Connector, AC Input Cord, General

Page 24

WARNING

Some components inside the power supply area are at AC voltage even when the On/Off switch is in the “Off” position. To avoid electric shock hazard, disconnect the line cord and load and wait two minutes before removing cover.

3.7.1 AC Input Connector

An IEC connector is provided on the rear panel for connecting the unit to the AC power source with an AC cord. The IEC connector also provides the safety ground connection while the AC cord is plugged into an appropriate AC receptacle.

3.7.2 AC Input Cord

Refer to Section 1.3.4 for details of the AC input cords recommended for the GENH750W mod- els.

WARNING

The AC input cord is the disconnect device of the power supply. The plug must be readily identifiable and accessible to the user. The AC input cord must be no longer than 3m.

3.8 TURN-ON CHECKOUT PROCEDURE

3.8.1 General

The following procedure ensures that the power supply is operational and may be used as a ba- sic incoming inspection check. Refer to Fig.4-1 and Fig.4-2 for the location of the controls indi- cated in the procedure.

3.8.2 Prior to Operation

1.Ensure that the power supply is configured to the default setting:

AC On/Off switch at Off position.

Dip switch: All positions at Down (“Off”) position.

Sense connector: Configured to Local Sense as shown in Fig.3-4:

1 Remote (+) sense

2 Local (+) sense

3 Not connected

4 Local (-) sense

5 Remote (-) sense

Fig.3-4: Sense connector default connection

For units equipped with IEEE option, ensure that the IEEE_En switch is in Up (default) position (Refer to Fig.4-2, Item 9 for location), if checkout is to be done in IEEE mode.

2.Connect the unit to an AC source as described in Section 3.7.

3.Connect a DVM with appropriate cables for the rated voltage to the output terminals.

4.Turn the front panel AC power switch to On.

16

83-507-5002 Rev. B

Image 24
Contents Genesystm 750W Half Rack Page Page Genesys Manual Supplement Table of Contents Front and Rear Panel Controls and CONNECTORS………... ……… ……… Isolated Analog Progamming Option ……………………………..…… Warranty Safety Instructions Safety Instructions SICHERHEITS-INSTALLATIONS Anweisungen Sicherheits-und Warnsymbole Anderungen and BauteileersatzUmweltbedingungen Features and options General InformationIntroduction General DescriptionMultiple output power system Control via the serial communication portAnalog voltage programming and monitoring Parallel operationAccessories Specifications ChapterFront Panel Supplemental Characteristics Genesystm Genh 750W Power Supplies Outline Drawings Installation General Preparation for USE Initial InspectionsSingle unit installation Rack MountingAC Input Power Connection LOCATION, Mounting and CoolingAC Source Requirements GENH/RM Rack Mounting outline drawingsTURN-ON Checkout Procedure AC Input ConnectorAC Input Cord GeneralConstant Voltage Check Constant Current CheckOVP Check UVL CheckConnecting the Load Wire termination AWGNoise and Impedance Effects Inductive loadsMaking the load connections 6V to 60V ModelsBus-bars shield mounting 80V to 600V Models 83-507-5002 Rev. B Connecting single loads, local sensing default Connecting single loads, remote sensingConnecting multiple loads, radial distribution method Multiple load connection with distribution terminals Grounding outputsSense wiring Output Terminal GroundingLocal and Remote Sensing Local sensing10.4 J2 sense connector technical information Remote sensingFront and Rear Panel Controls and Connectors Front Panel Controls and IndicatorsVoltage Auxiliary Function Rear Panel Connections and Controls Rear panel connections and controls Number DescriptionRear Panel SW1 Setup Switch 1 SW1 position functionRear Panel J1 Programming and Monitoring Connector Resetting the SW1 switchMaking J1 connections 83-507-5002 Rev. B Signal EnainIfcom LocalConstant Voltage Mode Constant Current ModeLocal Operation Standard OperationSetting the OVP level Resetting the OVP circuitOver Voltage Protection OVP Automatic CrossoverOutput SHUT-OFF SO Control VIA Rear Panel J1 Connector Under Voltage Limit UVLFoldback Protection Output ON/OFF ControlENABLE/DISABLE Control VIA Rear Panel J1 Connector CV/CC SignalPsok Signal Over Temperature Protecton OTPLast Setting Memory SAFE-START and AUTO-RESTART ModesSeries Operation Series connection for increased output voltageSeries connection for positive and negative output voltage Series connection for positive/negative output voltagesSetting up the Master unit Setting up the Slave unitsParallel Operation Basic parallel operationSetting Over Voltage protection Setting Foldback protectionAdvanced parallel configuration Setting the units as Master or SlaveMaster and Slave units default operation To release units from Slave modeCurrent display accuracy AST OFF OUT OFFDAISY-CHAIN Connection Front Panel LockingUnlocked front panel Locked front panelRemote Analog Programming LOCAL/REMOTE Analog IndicationDown Remote voltage programming connectionResisitive Programming of Output Voltage and Current Limit Remote resistive programmingRemote Monitoring of Output Voltage and Current RS232 & RS485 Remote Control ConfigurationRear Panel RS232/RS485 Connector 6 RS232/RS485 port in Local modeFront panel in Remote mode MD Mode Description MD Mode enable Serial communication modeMD Mode SRQ MD Mode SRQ RetransmissionConnecting Power Supplies to RS232 or RS485 BUS Single power supplyCommunication Interface Protocol Error Messages Command SET DescriptionInitialization Control Commands ID Control CommandsOutput Control Commands DVC? FilterFILTER? OUT?Global Output Commands Single Byte Commands Enable MD Mode MD Mode Option RequiredDisable SRQ retransmission MD Mode Option Required Enable SRQ retransmission MD Mode Option RequiredAddressed commands with response Read registers Print Power On TimeRetransmit Last Message Test if MD Mode is Installed Addressed commands without response Acknowledge SRQRe-enable SRQ with out reading/clearing the Seve Register 110x STATUS, Error and SRQ Registers Status Control CommandsConditional Registers TXDService Request Enable and Event Registers BITFault Enable Register Fault Event RegisterStatus Enable Register Status Event RegisterPower supply set-up Serial Communication Test SET-UPCommunication Test Specifications Isolated Analog Programming Option1 0-5V/0-10V Option PN IS510 PPM/CIsolated Programming & Monitoring Connector Setup and Operating Instructions Maintenance OUP Fuse Rating