CHAPTER 4 FRONT AND REAR PANEL CONTROLS AND CONNECTORS

4.1 INTRODUCTION

The GenesysTM Power Supply series has a full set of controls, indicators and connectors that al- low the user to easily setup and operate the unit. Before starting to operate the unit, please read the following Sections for explanation of the functions of the controls and connectors terminals.

-Section 4.2: Front Panel Controls and Indicators.

-Section 4.3: Rear Panel Connections and Controls.

4.2 FRONT PANEL CONTROLS AND INDICATORS

See Fig.4-1 to review the controls, indicators and meters located on the power supply front panel.

1

2

 

 

3

 

 

4

 

 

5

6

 

VOLTAGE

DC VOLTS

 

 

 

 

DC AMPS

CURRENT

 

 

 

 

 

 

OVP

 

 

 

 

 

 

 

 

ALARM

FINE

PREV/

UVL

 

REM/LOC

OUT

 

 

 

POWER

 

 

 

 

 

 

 

 

 

 

 

19

 

 

16

14

13

11

9

7

 

 

 

 

18

17

15

 

 

 

12

10

8

 

 

Fig.4-1: Front panel controls and indicators

Table 4-1: Front Panel controls and indicators

Number

Control/Indicator

Description

Section

 

 

 

 

1

VOLTAGE

High resolution rotary encoder for adjusting the Out-

5.2.1

 

control

put Voltage. Also adjusts the OVP/UVL levels and

5.3.1

 

 

selects the Address

5.4.1

 

 

 

7.2.2

2

VOLTAGE

Green LED, lights for constant-Voltage mode opera-

 

 

indicator

tion.

 

 

 

 

 

3

VOLTAGE

4 digit, 7-segment LED display. Normally displays

 

 

display

the Output Voltage. When the PREV button is

 

 

 

pressed, the display indicates the programmed set-

 

 

 

ting of the Output Voltage. When the OVP/UVL but-

 

 

 

ton is pressed, the Voltage display indicates the

 

 

 

OVP/UVL setting.

 

 

 

 

 

27

83-507-5002 Rev. B

Image 35
Contents Genesystm 750W Half Rack Page Page Genesys Manual Supplement Table of Contents Front and Rear Panel Controls and CONNECTORS………... ……… ……… Isolated Analog Progamming Option ……………………………..…… Warranty Safety Instructions Safety Instructions SICHERHEITS-INSTALLATIONS Anweisungen Umweltbedingungen Sicherheits-und WarnsymboleAnderungen and Bauteileersatz General Description Features and optionsGeneral Information IntroductionParallel operation Multiple output power systemControl via the serial communication port Analog voltage programming and monitoringAccessories Chapter SpecificationsFront Panel Supplemental Characteristics Genesystm Genh 750W Power Supplies Outline Drawings Initial Inspections InstallationGeneral Preparation for USERack Mounting Single unit installationGENH/RM Rack Mounting outline drawings AC Input Power ConnectionLOCATION, Mounting and Cooling AC Source RequirementsGeneral TURN-ON Checkout ProcedureAC Input Connector AC Input CordUVL Check Constant Voltage CheckConstant Current Check OVP CheckConnecting the Load AWG Wire termination6V to 60V Models Noise and Impedance EffectsInductive loads Making the load connectionsBus-bars shield mounting 80V to 600V Models 83-507-5002 Rev. B Connecting multiple loads, radial distribution method Connecting single loads, local sensing defaultConnecting single loads, remote sensing Grounding outputs Multiple load connection with distribution terminalsLocal sensing Sense wiringOutput Terminal Grounding Local and Remote SensingRemote sensing 10.4 J2 sense connector technical informationVoltage Front and Rear Panel Controls and ConnectorsFront Panel Controls and Indicators Auxiliary Function Rear panel connections and controls Number Description Rear Panel Connections and Controls1 SW1 position function Rear Panel SW1 Setup SwitchMaking J1 connections Rear Panel J1 Programming and Monitoring ConnectorResetting the SW1 switch 83-507-5002 Rev. B Local SignalEnain IfcomStandard Operation Constant Voltage ModeConstant Current Mode Local OperationAutomatic Crossover Setting the OVP levelResetting the OVP circuit Over Voltage Protection OVPOutput ON/OFF Control Output SHUT-OFF SO Control VIA Rear Panel J1 ConnectorUnder Voltage Limit UVL Foldback ProtectionCV/CC Signal ENABLE/DISABLE Control VIA Rear Panel J1 ConnectorSAFE-START and AUTO-RESTART Modes Psok SignalOver Temperature Protecton OTP Last Setting MemorySeries connection for increased output voltage Series OperationSeries connection for positive/negative output voltages Series connection for positive and negative output voltageBasic parallel operation Setting up the Master unitSetting up the Slave units Parallel OperationSetting the units as Master or Slave Setting Over Voltage protectionSetting Foldback protection Advanced parallel configurationAST OFF OUT OFF Master and Slave units default operationTo release units from Slave mode Current display accuracyFront Panel Locking DAISY-CHAIN ConnectionLocked front panel Unlocked front panelLOCAL/REMOTE Analog Indication Remote Analog ProgrammingRemote voltage programming connection DownRemote resistive programming Resisitive Programming of Output Voltage and Current LimitRemote Monitoring of Output Voltage and Current Configuration RS232 & RS485 Remote ControlFront panel in Remote mode Rear Panel RS232/RS485 Connector6 RS232/RS485 port in Local mode MD Mode SRQ Retransmission MD Mode DescriptionMD Mode enable Serial communication mode MD Mode SRQSingle power supply Connecting Power Supplies to RS232 or RS485 BUSCommunication Interface Protocol Command SET Description Error MessagesOutput Control Commands Initialization Control CommandsID Control Commands OUT? DVC?Filter FILTER?Global Output Commands Enable SRQ retransmission MD Mode Option Required Single Byte CommandsEnable MD Mode MD Mode Option Required Disable SRQ retransmission MD Mode Option RequiredRetransmit Last Message Addressed commands with response Read registersPrint Power On Time Re-enable SRQ with out reading/clearing the Seve Register Test if MD Mode is InstalledAddressed commands without response Acknowledge SRQ 110x Status Control Commands STATUS, Error and SRQ RegistersTXD Conditional RegistersBIT Service Request Enable and Event RegistersFault Event Register Fault Enable RegisterStatus Event Register Status Enable RegisterCommunication Test Power supply set-upSerial Communication Test SET-UP PPM/C SpecificationsIsolated Analog Programming Option 1 0-5V/0-10V Option PN IS510Isolated Programming & Monitoring Connector Setup and Operating Instructions Maintenance OUP Fuse Rating