TDK 750W HALF RACK technical manual Front Panel

Page 18

2.6 PROGRAMMING AND READBACK (RS232/485, Optional IEEE Interface)

1.

Vout programming accuracy

 

 

0.05% + 0.05% of rated output voltage.

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Iout programming accuracy (*13)

 

 

0.1% of actual output current + 0.1% of rated output current (for Iout >0.4% of rated Iout to 100% of rated Iout).

 

 

 

 

 

 

 

 

0.1% of actual output current +0.4% of rated output current (for Iout <0.4% of rated Iout to 0.4% of rated Iout).

 

 

 

3.

Vout programming resolution.

 

 

0.012% of full scale.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Iout programming resolution

 

 

0.012% of full scale.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.

Vout readback accuracy

 

 

0.1% + 0.1% of rated output voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

6.

Iout readback accuracy (*13)

 

 

0.1% + 0.3% of rated output current

 

 

 

 

 

 

 

 

 

 

 

 

 

7.

Vout readback resolution

 

 

0.012% of full scale

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.

Iout readback resolution

 

 

0.012% of full scale

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.7 PROTECTIVE FUNCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

6

8

12.5

 

20

 

30

40

50

60

 

80

 

100

150

300

600

1.

Foldback protection

 

Output shut

-down when power supply changes from CV to CC. User presetable.

 

 

 

 

 

 

 

 

 

2.

Over-voltage protection

 

Inverter shut-down; manual reset by AC input recycle, OUT button.

 

 

 

 

 

 

 

 

 

 

3.

Over-voltage trip point

 

V

 

0.5-7.5

0.5-10

1-15

 

1-24

 

2-35

2-44.1

5-57

5-66

 

5-88

 

5-110

5-165

5-330

5-660

4.

Output under voltage limit

 

Preset by

front panel

or communication port. Prevents adjusting Vout below limit. Raises the PS_OK signal in case

 

 

 

 

 

 

 

output

voltage is below limit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.

Over temperature protection

 

User selectable, latched or non latched.

 

 

 

 

 

 

 

 

 

 

 

 

 

2.8 FRONT PANEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Control functions

 

 

Vout/Iout manual adjust by separate encoders. (Coarse and fine adjustment)

 

 

 

 

 

 

 

 

 

 

 

 

OVP/UVL manual adjust by Volt. Adjust encoder

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Address selection by Voltage adjust encoder. No of addresses: 31

 

 

 

 

 

 

 

 

 

 

 

 

 

Go to local control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output on/off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC on/off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front panel lock

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Foldback control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial or IEEE display at power-up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Baud rate selection: 1200, 2400, 4800, 9600 and 19200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Re-start modes (Auto Restart, Safe Start)

 

 

 

 

 

 

 

 

 

 

 

2.

Display

 

 

Vout:

4 digits, accuracy: 0.5% of rated voltage + 1 count

 

 

 

 

 

 

 

 

 

 

 

 

 

Iout:

4 digits, accuracy: 0.5% of rated current + 1 count

 

 

 

 

 

 

 

 

 

3. Indications

 

 

VOLTAGE,

CURRENT, ALARM FINE, PREVIEW, FOLDBACK, LOCAL, OUTPUT ON.

 

 

 

 

 

 

2.9 ENVIRONMENTAL CONDITIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Operating temperature

 

C

 

0~50 C, 100% load.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Storage temperature

 

C

 

-20 to + 70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Operating humidity

 

%

 

30~90% RH (no condensation).

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Storage humidity

 

%

 

10~95% RH (no condensation).

 

 

 

 

 

 

 

 

 

 

 

 

 

5.

Altitude

 

 

Maximum 3000m, Derate output current by 2%/100m above 2000m. Alternatively, derate maximum ambient

 

 

 

 

 

 

 

 

temperature by 1 degC/100m above 2000m.

 

 

 

 

 

 

 

 

 

 

 

2.10 MECHANICAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Cooling

 

 

Forced air cooled by internal fans.

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Weight

 

Kg

 

Less than 4.5Kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Dimensions (W x H x D)

 

mm

 

W: 214.0 H: 43.6 (57.0 Benchtop Version). D: 437.5 (Refer to Outline drawing).

 

 

 

 

 

 

 

 

4.

Vibration

 

 

MIL-810E, method 514.5 test condition l-3.3

 

 

 

 

 

 

 

 

 

 

 

5.

Shock

 

 

Less than 20G, half sine, 11mS. Units unpacked

 

 

 

 

 

 

 

 

 

 

 

2.11 SAFETY/EMC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Applicable standards

Safety

 

UL60950-1 listed, EN60950-1 Vout 40V: Output is SELV, IEEE/Isolated Analog are SELV.

 

 

 

 

 

 

 

 

 

 

 

 

 

60 < Vout < 400V: Output is hazardous, IEEE/Isolated analog are SELV

 

 

 

 

 

 

 

 

 

 

 

400 < Vout < 600V: Output is hazardous, IEEE/Isolated, Analog are not SELV

 

 

 

 

 

EMC

 

EN55024

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Withstand voltage

 

 

Vout < 60V models: Input-Outputs (SELV): 3.0KVrms 1 min, Input-Ground: 2.0KVrms 1 min.

 

 

 

 

 

 

 

 

 

 

 

60 Vout 600V models: Input-Haz, output: 2.5KVrms 1 min, Input-SELV: 3KVrms 1 min, 1900VDC 1 min.

 

 

 

 

 

 

 

 

Hazardous Output - SELV: 1.9KVrms 1 min, Hazardous Output-Ground: 1.9KVrms 1 min.

 

 

 

 

 

 

 

 

 

 

 

Input-Ground: 2KVrms 1min

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Insulation resistance

 

 

More than 100Mohm at 25°C, 70%RH

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Conducted emission

 

 

EN55022B, FCC part 15-B, VCCI-B

 

 

 

 

 

 

 

 

 

 

 

 

 

5.

Radiated emission

 

 

EN55022A, FCC part 15-A, VCCI-A

 

 

 

 

 

 

 

 

 

 

 

 

 

10

83-507-5002 Rev. B

Image 18
Contents Genesystm 750W Half Rack Page Page Genesys Manual Supplement Table of Contents Front and Rear Panel Controls and CONNECTORS………... ……… ……… Isolated Analog Progamming Option ……………………………..…… Warranty Safety Instructions Safety Instructions SICHERHEITS-INSTALLATIONS Anweisungen Sicherheits-und Warnsymbole Anderungen and BauteileersatzUmweltbedingungen Introduction Features and optionsGeneral Information General DescriptionAnalog voltage programming and monitoring Multiple output power systemControl via the serial communication port Parallel operationAccessories Specifications ChapterFront Panel Supplemental Characteristics Genesystm Genh 750W Power Supplies Outline Drawings Preparation for USE InstallationGeneral Initial InspectionsSingle unit installation Rack MountingAC Source Requirements AC Input Power ConnectionLOCATION, Mounting and Cooling GENH/RM Rack Mounting outline drawingsAC Input Cord TURN-ON Checkout ProcedureAC Input Connector GeneralOVP Check Constant Voltage CheckConstant Current Check UVL CheckConnecting the Load Wire termination AWGMaking the load connections Noise and Impedance EffectsInductive loads 6V to 60V ModelsBus-bars shield mounting 80V to 600V Models 83-507-5002 Rev. B Connecting single loads, local sensing default Connecting single loads, remote sensingConnecting multiple loads, radial distribution method Multiple load connection with distribution terminals Grounding outputsLocal and Remote Sensing Sense wiringOutput Terminal Grounding Local sensing10.4 J2 sense connector technical information Remote sensingFront and Rear Panel Controls and Connectors Front Panel Controls and IndicatorsVoltage Auxiliary Function Rear Panel Connections and Controls Rear panel connections and controls Number DescriptionRear Panel SW1 Setup Switch 1 SW1 position functionRear Panel J1 Programming and Monitoring Connector Resetting the SW1 switchMaking J1 connections 83-507-5002 Rev. B Ifcom SignalEnain LocalLocal Operation Constant Voltage ModeConstant Current Mode Standard OperationOver Voltage Protection OVP Setting the OVP levelResetting the OVP circuit Automatic CrossoverFoldback Protection Output SHUT-OFF SO Control VIA Rear Panel J1 ConnectorUnder Voltage Limit UVL Output ON/OFF ControlENABLE/DISABLE Control VIA Rear Panel J1 Connector CV/CC SignalLast Setting Memory Psok SignalOver Temperature Protecton OTP SAFE-START and AUTO-RESTART ModesSeries Operation Series connection for increased output voltageSeries connection for positive and negative output voltage Series connection for positive/negative output voltagesParallel Operation Setting up the Master unitSetting up the Slave units Basic parallel operationAdvanced parallel configuration Setting Over Voltage protectionSetting Foldback protection Setting the units as Master or SlaveCurrent display accuracy Master and Slave units default operationTo release units from Slave mode AST OFF OUT OFFDAISY-CHAIN Connection Front Panel LockingUnlocked front panel Locked front panelRemote Analog Programming LOCAL/REMOTE Analog IndicationDown Remote voltage programming connectionResisitive Programming of Output Voltage and Current Limit Remote resistive programmingRemote Monitoring of Output Voltage and Current RS232 & RS485 Remote Control ConfigurationRear Panel RS232/RS485 Connector 6 RS232/RS485 port in Local modeFront panel in Remote mode MD Mode SRQ MD Mode DescriptionMD Mode enable Serial communication mode MD Mode SRQ RetransmissionConnecting Power Supplies to RS232 or RS485 BUS Single power supplyCommunication Interface Protocol Error Messages Command SET DescriptionInitialization Control Commands ID Control CommandsOutput Control Commands FILTER? DVC?Filter OUT?Global Output Commands Disable SRQ retransmission MD Mode Option Required Single Byte CommandsEnable MD Mode MD Mode Option Required Enable SRQ retransmission MD Mode Option RequiredAddressed commands with response Read registers Print Power On TimeRetransmit Last Message Test if MD Mode is Installed Addressed commands without response Acknowledge SRQRe-enable SRQ with out reading/clearing the Seve Register 110x STATUS, Error and SRQ Registers Status Control CommandsConditional Registers TXDService Request Enable and Event Registers BITFault Enable Register Fault Event RegisterStatus Enable Register Status Event RegisterPower supply set-up Serial Communication Test SET-UPCommunication Test 1 0-5V/0-10V Option PN IS510 SpecificationsIsolated Analog Programming Option PPM/CIsolated Programming & Monitoring Connector Setup and Operating Instructions Maintenance OUP Fuse Rating