WARNING
OUTPUT TERMINAL GROUNDING
There is a potential shock hazard at the RS232/RS485 and the IEEE ports when using power supplies with rated or combined voltage greater than 400V with the Positive Output of the power supplies grounded. Do not connect the Positive out- put to ground when using the RS232/RS485 or IEEE under the above conditions.
3.10 LOCAL AND REMOTE SENSING
The rear panel J2 sense connector is used to configure the power supply for local or remote sensing of the Output Voltage. Refer to
3.10.1 Sense wiring
WARNING
There is a potential shock hazard at the sense connector when using a power supply with a rated Output Voltage greater than 40V. Local sense and remote sense wires should have a minimum insulation rating equivalent or greater than the maximum Output Voltage of the power supply. Ensure that the connections at the load end are shielded to prevent accidental contact with hazardous voltages.
3.10.2 Local sensing
The power supply is shipped with the rear panel J2 sense connector wired for local sensing of the Output Voltage. See Table
|
|
Table | |
|
|
Terminal | Function |
Remote positive sense (+S) | |
Local positive sense. Connected internally to the positive output terminal (+LS). | |
Not connected (NC) | |
Local negative sense. Connected internally to the negative output terminal | |
Remote negative sense |
25