TDK 750W HALF RACK technical manual 110x

Page 70

Print Power On

Byte 1

Power On

Read the time the supply is active

Time

1010 0110

time in min-

under AC Power. xxxx xxxx is the

 

Byte 2

utes

address of the supply in binary.

 

xxxx xxxx

 

Returns a 32 Bit integer as 8 Hex

 

 

 

bytes. A ‘$’ sign is appended to

 

 

 

the data followed by a 2 byte

 

 

 

check-sum. A total of 11 bytes are

 

 

 

returned.

Retransmit last

110x xxxx

Last message

Retransmit last response from a

message

 

 

command. x xxxx is the address of

 

 

 

the supply in binary.

Acknowledge

111x xxxx

None

Acknowledge SRQ. If retransmis-

SRQ

 

 

sion of SRQ is enabled, it will re-

 

 

 

main enabled for the next SRQ. X

 

 

 

xxxx is the address of the supply

 

 

 

in binary.

Test if MD Mode

Byte 1

0 or 1

Returns a 0 if not installed or a 1 if

is Installed

1010 1010

 

installed. A ‘$’ sign followed by a 2

 

Byte 2

 

bytes checksum and Carriage Re-

 

xxxx xxxx

 

turn is appended to the data. xxxx

 

 

 

xxxx is the address of the supply

 

 

 

in binary.

Supply Initiated

 

 

 

Communications

 

 

 

SRQ

100x xxxx

N/A

SRQ from supply when in MD

 

 

 

Mode. X xxxx is the address of the

 

 

 

supply in binary.

 

Table 7-4. SINGLE BYTE COMMUNICATIONS

GEN750W models

Table 7-5: Current programming range

Model

Minimum

Maximum

 

(A)

(A)

GEN6-100

000.00

100.00

 

 

 

GEN8-90

00.00

90.00

 

 

 

GEN12.5-60

00.000

60.000

 

 

 

GEN20-38

00.000

38.000

 

 

 

GEN30-25

00.000

25.000

 

 

 

GEN40-19

00.000

19.000

 

 

 

GEN60-12.5

00.000

12.500

 

 

 

GEN80-9.5

0.000

9.500

 

 

 

GEN100-7.5

0.000

7.500

 

 

 

GEN150-5

0.000

5.000

 

 

 

GEN300-2.5

0.000

2.500

 

 

 

GEN600-1.3

0.000

1.300

 

 

 

NOTE:

The power supply can accept values 5% higher than the table values, however it is not recommended to program the power supply over the rated values.

62

83-507-5002 Rev. B

Image 70
Contents Genesystm 750W Half Rack Page Page Genesys Manual Supplement Table of Contents Front and Rear Panel Controls and CONNECTORS………... ……… ……… Isolated Analog Progamming Option ……………………………..…… Warranty Safety Instructions Safety Instructions SICHERHEITS-INSTALLATIONS Anweisungen Anderungen and Bauteileersatz Sicherheits-und WarnsymboleUmweltbedingungen Introduction Features and optionsGeneral Information General DescriptionAnalog voltage programming and monitoring Multiple output power systemControl via the serial communication port Parallel operationAccessories Specifications ChapterFront Panel Supplemental Characteristics Genesystm Genh 750W Power Supplies Outline Drawings Preparation for USE InstallationGeneral Initial InspectionsSingle unit installation Rack MountingAC Source Requirements AC Input Power ConnectionLOCATION, Mounting and Cooling GENH/RM Rack Mounting outline drawingsAC Input Cord TURN-ON Checkout ProcedureAC Input Connector GeneralOVP Check Constant Voltage CheckConstant Current Check UVL CheckConnecting the Load Wire termination AWGMaking the load connections Noise and Impedance EffectsInductive loads 6V to 60V ModelsBus-bars shield mounting 80V to 600V Models 83-507-5002 Rev. B Connecting single loads, remote sensing Connecting single loads, local sensing defaultConnecting multiple loads, radial distribution method Multiple load connection with distribution terminals Grounding outputsLocal and Remote Sensing Sense wiringOutput Terminal Grounding Local sensing10.4 J2 sense connector technical information Remote sensingFront Panel Controls and Indicators Front and Rear Panel Controls and ConnectorsVoltage Auxiliary Function Rear Panel Connections and Controls Rear panel connections and controls Number DescriptionRear Panel SW1 Setup Switch 1 SW1 position functionResetting the SW1 switch Rear Panel J1 Programming and Monitoring ConnectorMaking J1 connections 83-507-5002 Rev. B Ifcom SignalEnain LocalLocal Operation Constant Voltage ModeConstant Current Mode Standard OperationOver Voltage Protection OVP Setting the OVP levelResetting the OVP circuit Automatic CrossoverFoldback Protection Output SHUT-OFF SO Control VIA Rear Panel J1 ConnectorUnder Voltage Limit UVL Output ON/OFF ControlENABLE/DISABLE Control VIA Rear Panel J1 Connector CV/CC SignalLast Setting Memory Psok SignalOver Temperature Protecton OTP SAFE-START and AUTO-RESTART ModesSeries Operation Series connection for increased output voltageSeries connection for positive and negative output voltage Series connection for positive/negative output voltagesParallel Operation Setting up the Master unitSetting up the Slave units Basic parallel operationAdvanced parallel configuration Setting Over Voltage protectionSetting Foldback protection Setting the units as Master or SlaveCurrent display accuracy Master and Slave units default operationTo release units from Slave mode AST OFF OUT OFFDAISY-CHAIN Connection Front Panel LockingUnlocked front panel Locked front panelRemote Analog Programming LOCAL/REMOTE Analog IndicationDown Remote voltage programming connectionResisitive Programming of Output Voltage and Current Limit Remote resistive programmingRemote Monitoring of Output Voltage and Current RS232 & RS485 Remote Control Configuration6 RS232/RS485 port in Local mode Rear Panel RS232/RS485 ConnectorFront panel in Remote mode MD Mode SRQ MD Mode DescriptionMD Mode enable Serial communication mode MD Mode SRQ RetransmissionConnecting Power Supplies to RS232 or RS485 BUS Single power supplyCommunication Interface Protocol Error Messages Command SET DescriptionID Control Commands Initialization Control CommandsOutput Control Commands FILTER? DVC?Filter OUT?Global Output Commands Disable SRQ retransmission MD Mode Option Required Single Byte CommandsEnable MD Mode MD Mode Option Required Enable SRQ retransmission MD Mode Option RequiredPrint Power On Time Addressed commands with response Read registersRetransmit Last Message Addressed commands without response Acknowledge SRQ Test if MD Mode is InstalledRe-enable SRQ with out reading/clearing the Seve Register 110x STATUS, Error and SRQ Registers Status Control CommandsConditional Registers TXDService Request Enable and Event Registers BITFault Enable Register Fault Event RegisterStatus Enable Register Status Event RegisterSerial Communication Test SET-UP Power supply set-upCommunication Test 1 0-5V/0-10V Option PN IS510 SpecificationsIsolated Analog Programming Option PPM/CIsolated Programming & Monitoring Connector Setup and Operating Instructions Maintenance OUP Fuse Rating