Installation

Wiring Requirements

Use twisted-pair cable for all connections.

NOTE:

Before attaching your DEFINITY Extender 1100 System to the DEFINITY ECS, do the following:

Administer the telephone that will be used at the remote location.

Connect an identical model telephone to the DEFINITY ECS port that will be used for connecting to the Switch Module.

Test that the telephones work as intended.

Connecting the Switch Module

All connections to the Switch Module are done via the back panel (see Figure 3-1).The current back panel elements are:

Telco Line is the connection between the Switch Module and the DEFINITY ECS analog circuit pack or the central office line for transmission of the signaling information. The circuit packs to which the Switch Module can be connected are the 8-port TN742 and the 16-port TN746.

Phone/Switch is the connection between the DEFINITY ECS 2-wire, 24-port circuit pack (TN2224) or the other 16-port, (TN2181) and the Switch Module.

Issue 1 June 1998 3-3

Image 58
Contents Definity Extender Federal Communications Commission Statement Industry Canada IC Interference Information Contents Introduction Connecting the Switch Module GL-1 Figures Tables Important Safety Instructions Viii Issue 1 June Customer Support Information Support Telephone Number Security of Your System Preventing Toll Fraud Lucent Technologies Fraud Intervention Lucent Technologies Limited Warranty FCC Notification Repair Information Installation and Operational Procedures Customer Support Information Customer Support Information Xvi Issue 1 June About This Book Intended AudienceTerms and Conventions Security AlertHow to Use This Book Typographical ConventionsProduct Safety Labels Related Documents CallToll Fraud Security How to Comment on This Document Feedback Form This Form MAY be Photocopied Introduction1 System Operation Configuration System ConfigurationSecurity Alert Equipment List Switch ModuleCustomer-Supplied Equipment Compatibility Specifications OptionsPage Switch Module Specifications Description Considerations 10Issue 1 June Configuration2 Password ConsiderationsProgramming the Switch Module Page Configure System Exit Enhanced Terminal InterfaceTerminal Edit Line Configuring the COM RS-232D Port Configuration Stop Bits Issue 1 June 1998 Setting Parity Setting Data RateSetting Data Bit Show Settings Setting Stop BitsAdditional Modem Initialization Setting Passwords Security Alert Considerations Programming Passwords Procedure To check a password Configuring Passwords Online To disable a passwordPage Configuration Issue 1 June 1998 Installation3 Location Requirements Electrical RequirementsWiring Requirements Connecting the Switch ModuleInstallation Procedure Switch Module Back PanelDIP Switch Configuration Installation Connections for Data Transmission Female Connector on Module Hardware Flow Control Installation 10Issue 1 June Troubleshooting4 Troubleshooting LED Sequences LED Power up Sequences LED Sequence Description LED Power up Verification Sequences LED Sequence Description Module is online to a Remote Module no Rgrg Error Messages Error Messages Cause ActionError Messages Cause Action No Display on Telephone at Remote Location Specific ProblemsNo Connection/No Answer Page Reporting a Faulty Switch Module Troubleshooting Issue 1 June 1998 Glossary GL-2Issue 1 June Issue 1 June 1998 GL-3 GL-4Issue 1 June Issue 1 June 1998 GL-5 Glossary GL-6Issue 1 June