CYV15G0104TRB
INSELA input. The Serial Line Receiver inputs are differential, and can accommodate wire interconnect and filtering losses or transmission line attenuation greater than 16 dB. For normal operation, these inputs should receive a signal of at least VIDIFF > 100 mV, or 200 mV
Signal Detect/Link Fault
Each selected Line Receiver (i.e., that routed to the clock and data recovery PLL) is simultaneously monitored for
•analog amplitude above amplitude level selected by
SDASELA
•transition density above the specified limit
•range controls report the received data stream inside normal frequency range (±1500 ppm[24])
•receive channel enabled
•Presence of reference clock
•ULCA is not asserted.
All of these conditions must be valid for the Signal Detect block to indicate a valid signal is present. This status is presented on the LFIA (Link Fault Indicator) output associated with each receive channel, which changes synchronous to the receive interface clock.
Analog Amplitude
While most signal monitors are based on fixed constants, the analog amplitude level detection is adjustable to allow operation with highly attenuated signals, or in
Table 2. Analog Amplitude Detect Valid Signal Levels[7]
Typical Signal with Peak Amplitudes
SDASELA Above
00Analog Signal Detector is disabled
01140 mV
10280 mV
11420 mV
Transition Density
The Transition Detection logic checks for the absence of transitions spanning greater than six transmission characters
(60 bits). If no transitions are present in the data received, the Detection logic for that channel asserts LFIA.
Note:
Range Controls
The CDR circuit includes logic to monitor the frequency of the PLL Voltage Controlled Oscillator (VCO) used to sample the incoming data stream. This logic ensures that the VCO operates at, or near the rate of the incoming data stream for two primary cases:
•when the incoming data stream resumes after a time in which it has been “missing.”
•when the incoming data stream is outside the acceptable signaling rate range.
To perform this function, the frequency of the RXPLL VCO is periodically compared to the frequency of the TRGCLKA± input. If the VCO is running at a frequency beyond ±1500ppm[24] as defined by the TRGCLKA± frequency, it is periodically forced to the correct frequency (as defined by TRGCLKA±, SPDSELA, and TRGRATEA) and then released in an attempt to lock to the input data stream.
The sampling and relock period of the Range Control is calcu- lated as follows: RANGE_CONTROL_ SAMPLING_PERIOD = (RECOVERED BYTE CLOCK PERIOD) * (4096).
During the time that the Range Control forces the RXPLL VCO to track TRGCLKA±, the LFIA output is asserted LOW. After a valid serial data stream is applied, it may take up to one RANGE CONTROL SAMPLING PERIOD before the PLL locks to the input data stream, after which LFIA should be HIGH.
The operating serial
Table 3. Operating Speed Settings
|
| TRGCLKA± | Signaling |
SPDSELA | TRGRATEA | Frequency | |
(MHz) | Rate (Mbps) | ||
LOW | 1 | reserved | |
| 0 |
| |
MID (Open) | 1 | ||
| 0 |
| |
HIGH | 1 | ||
| 0 |
|
Receive Channel Enabled
The receive channel can be enabled or disabled through the RXPLLPDA input latch as controlled by the device configu- ration interface. When RXPLLPDA = 0, the CDR PLL and analog circuitry of the channel are disabled. Any disabled channel indicates a constant link fault condition on the LFIA output. When RXPLLPDA = 1, the CDR PLL and receive channel are enabled to receive a serial stream.
Note. When the disabled receive channel is reenabled, the status of the LFIA output and data on the parallel outputs for the associated channel may be indeterminate for up to 2 ms.
Clock/Data Recovery
The extraction of a