Cypress manual CYV15G0404RB DC Electrical Characteristics, AC Test Loads and Waveforms

Page 20

CYV15G0404RB

CYV15G0404RB DC Electrical Characteristics (continued)

Parameter

 

Description

 

 

 

 

Test Conditions

 

Min

 

Max

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Differential CML Serial Outputs: ROUTA1±, ROUTA2±, ROUTB1±, ROUTB2±, ROUTC1±, ROUTC2±, ROUTD1±, ROUTD2±

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOHC

Output HIGH Voltage

 

 

 

100differential load

 

VCC – 0.5

 

VCC – 0.2

V

 

(VCC Referenced)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150differential load

 

VCC – 0.5

 

VCC – 0.2

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLC

Output LOW Voltage

 

 

 

100differential load

 

VCC – 1.4

 

VCC – 0.7

V

 

(VCC Referenced)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150differential load

 

VCC – 1.4

 

VCC – 0.7

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VODIF

Output Differential Voltage

 

 

 

100differential load

 

450

 

900

mV

 

(OUT+) (OUT)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150differential load

 

560

 

1000

mV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Differential Serial Line Receiver Inputs: INA1±, INA2±, INB1±, INB2±, INC1±, INC2±, IND1±, IND2±

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VDIFFs[7]

Input Differential Voltage (IN+) (IN)

 

 

 

 

 

100

 

1200

mV

VIHE

Highest Input HIGH Voltage

 

 

 

 

 

 

 

 

 

 

 

VCC

V

VILE

Lowest Input LOW Voltage

 

 

 

 

 

 

 

 

VCC – 2.0

 

 

V

IIHE

Input HIGH Current

 

 

 

VIN = VIHE Max.

 

 

 

 

1350

µA

IILE

Input LOW Current

 

 

 

VIN = VILE Min.

 

–700

 

 

µA

VICOM[9]

Common Mode input range

 

 

 

((VCC – 2.0V)+0.5)min,

 

+1.25

 

+3.1

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(VCC

– 0.5V) max.

 

 

 

 

 

 

Power Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typ

 

Max

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ICC [10,11]

Max Power Supply Current

 

 

 

TRGCLKx=

Commercial

 

910

 

1270

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Industrial

 

 

 

 

1320

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ICC [10,11]

Typical Power Supply Current

 

 

 

TRGCLKx=

Commercial

 

900

 

1270

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

125 MHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Industrial

 

 

 

 

1320

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC Test Loads and Waveforms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.3V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R1 = 590

 

 

 

 

 

 

 

 

 

 

 

 

 

R1

 

 

RL = 100

 

RL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Includes fixture and

 

 

 

 

R2 = 435

CL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CL 7 pF

 

 

 

 

 

R2

 

 

probe capacitance)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Includes fixture and

 

 

 

 

 

 

 

 

 

 

 

(b) CML Output Test Load

[12]

 

 

 

 

 

 

 

 

 

 

 

probe capacitance)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(a) LVTTL Output Test Load[12]

Vth = 1.4V

GND

1 ns

3.0V

2.0V 2.0V

0.8V 0.8V

VIHE

Vth = 1.4V

20%

VILE

1 ns

270 ps

VIHE

80%80%

VILE

20%

270 ps

(c) LVTTL Input Test Waveform[13]

(d) CML/LVPECL Input Test Waveform

Notes

9.The common mode range defines the allowable range of INPUT+ and INPUTwhen INPUT+ = INPUT. This marks the zero crossing between the true and complement inputs as the signal switches between a logic-1 and a logic-0.

10.Maximum ICC is measured with VCC = MAX, TA = 25°C, with all channels and Serial Line Drivers enabled, sending a continuous alternating 01 pattern, and outputs unloaded.

11.Typical ICC is measured under similar conditions except with VCC = 3.3V, TA = 25°C, with all channels enabled and one Serial Line Driver for each transmit channel sending a continuous alternating 01 pattern. The redundant outputs on each channel are powered down and the parallel outputs are unloaded.

12.Cypress uses constant current (ATE) load configurations and forcing functions. This figure is for reference only.

13.The LVTTL switching threshold is 1.4V. All timing references are made relative to where the signal edges cross the threshold voltage.

Document #: 38-02102 Rev. *C

Page 20 of 27

[+] Feedback

Image 20
Contents Cypress Semiconductor Corporation FeaturesFunctional Description CYV15G0404RB Deserializing Reclocker Logic Block Diagram Reclocking Deserializer Path Block Diagram Clock Device Configuration and Control Block Diagram = Internal SignalPin Configuration Top View1 Pin Configuration Bottom View1 Asynchronous Device Reset Receive Path Clock SignalsDevice Control Signals Name IO Characteristics Signal Description Link Fault Indication OutputDevice Configuration and Control Bus Signals Control Write Enable .Internal Device Configuration Latches Signal Detect Amplitude SelectReceive Channel Power Control Receive Bist DisabledCYV15G0404RB HOTLink II Operation CYV15G0404RB Receive Data PathClock/Data Recovery LOWHigh ReclockerPower Control Device Configuration and Control InterfaceForce Global Enable Function Mask FunctionLatch Types Static Latch ValuesDevice Configuration Strategy Device Control Latch Configuration Table DATA7 DATA6 DATA5 DATA4 DATA3 DATA2 DATA1 DATA0Level Select Inputs Jtag SupportReceive Bist Status Bits RX PLL BiststartBistwait Bistdatacompare 000CYV15G0404RB DC Electrical Characteristics Operating Range Maximum RatingsCYV15G0404RB DC Electrical Characteristics AC Test Loads and WaveformsCYV15G0404RB AC Electrical Characteristics PLL Characteristics Capacitance14Parameter Description Min Max Unit CYV15G0404RB Device Parameter Description Test Conditions Max UnitBus Configuration Write Timing Receive Interface Read Timing RXRATEx =VCC Power CMLLvttl in PU CML OUTROUTB2+ CML OUT TDI Lvttl in PURXDB8 Lvttl OUT TMS Lvttl in PUPackage Diagram Ordering InformationSpeed Ordering Code Package Package Type Operating RangeDocument History FRESUA AGT