RAD Data comm RIC-155 operation manual Features, 10/100BaseT Interface, STM-1/OC-3c Interface

Page 16

Chapter 1 Introduction

RIC-155Installation and Operation Manual

 

 

Features

10/100BaseT Interface

RIC-155 Fast Ethernet interface operation conforms to the IEEE 802.3u, 802.3x and 802.1p standards, including VLAN applications. The Fast Ethernet interface supports the following functions:

Four levels of QoS, according to ToS or 802.3p

High performance lookup engine with support for up to 1024 MAC address entries with automatic learning and aging

Autonegotiation

Backpressure

Half duplex and full duplex operation

FDX flow control

Automatic MDI/MDIX crossover.

STM-1/OC-3c Interface

RIC-155 converts Ethernet/Fast Ethernet signals into POS and vice. The STM-1/OC-3c interface terminates into fiber optic or 75BNC coaxial connectors. Single mode fiber optic interface of the unit uses a 1310 nm LED or 1310/1550 laser diode transmitters (see Table 1-1).

The STM-1/OC-3c interface of RIC-155 operates with internal or receive clock.

Table 1-1. Fiber Optic Interface Options

Wavelength

Fiber Type

Transmitter

Power

Receiver

Typical Max.

Connector

 

 

Type

 

Sensitivity

Range

 

[nm]

[m]

 

[dBm]

[dBm]

[km/miles]

 

 

 

 

 

 

 

 

1310

62.5/125,

LED

-18

-31

2/1.2

SC

 

multimode

 

 

 

 

 

 

 

 

 

 

 

 

1310

9/125 single mode

Laser

-12

-31

20/12.4

ST, SC, FC

 

 

 

 

 

 

 

1310

9/125 single mode

Laser, long haul

-2

-34

40/25

ST, SC, FC

 

 

 

 

 

 

 

1550

9/125 single mode

Laser, long haul

-2

-34

80/49.7

SC

 

 

 

 

 

 

 

SF1 (WDM)

9/125 single mode

Laser

-12

-29

20/12.4

SC

 

 

Tx – 1310

 

 

 

 

 

 

Rx – 1550

 

 

 

 

SF2 (WDM)

9/125 single mode

Laser

-12

-29

20/12.4

SC

 

 

Tx – 1550

 

 

 

 

 

 

Rx – 1310

 

 

 

 

SF3

9/125 single mode

Laser, 1310

-12

-27

20/12.4

SC/APC

(single fiber)

 

Tx and Rx

 

 

 

 

 

 

 

 

 

 

 

1-2 Overview

Image 16
Contents RIC-155 Page RIC-155 Limited Warranty General Safety Instructions Please observe the following precautionsConnection of AC Mains General Safety PracticesConnection of DC Mains Ports Safety Status Connection of Data and Telecommunications CablesElectromagnetic Compatibility EMC Canadian Emission Requirements ConventionsSafety Manufacturers Name Manufacturers AddressProduct Name Supplementary InformationConfiguring RIC-155 Installing RIC-155Quick Start Guide Configuring RIC-155 To configure RIC-155Contents Troubleshooting and Diagnostics Appendix A. Connector Wiring Appendix B. Traffic SeparationChapter Introduction OverviewVersions ApplicationFeatures 10/100BaseT InterfaceSTM-1/OC-3c Interface Fiber Optic Interface OptionsAlarm Relay ManagementInternal Bridge Status ReportingPhysical Description RIC-155 3D ViewRIC-155 Block Diagram Functional DescriptionTechnical Specifications Alarm Types Major and minor Connector DB-9, female Temperature 50C / 32-122F Humidity Up to 90%, non-condensingIntroduction Introduction Chapter Installation and SetupSite Requirements and Prerequisites Package Contents Connecting the Interface CablesConnecting AC Power Connecting the Power CableConnecting DC Power Connecting the Power Cable Controls and Indicators Chapter OperationTurning On RIC-155 To turn on RIC-155RIC-155 Normal Indicator Status Indicator StatusRIC-155 LEDs Name Function LocationDefault Settings RIC-155 Default SettingsConfiguration Alternatives Parameter Default ValueManaging RIC-155 via Terminal Port UplinkManaging RIC-155 via Ethernet Ports Preparing the TerminalStarting Terminal Session for a First Time To prepare RIC-155 for network managementTo start a ConfiguRAD session Loging on To enter the user name and passwordNavigating the Management Menus Menu MapTo choose an option ConfiguRAD session Choosing OptionsCorrecting Entries To choose an option terminal sessionNavigating Tables Turning Off RIC-155Logging Out Operation Turning Off RIC-155 Chapter Configuration Configuring RIC-155 for ManagementTo access the Configuration menu To access the Management menuEntering Device Information To enter device informationConfiguring the Host Parameters To define the IP parametersConfiguring the Network Managers To configure the network managersControlling the Management Access To define the management access methodConfiguring the RIC-155 for Operation To enable or disable management portsConfiguring the Clock Source Configuring Control Port ParametersConfiguring the Security Timeout Enabling and Disabling Pop-up AlarmsChanging the Control Port Data Rate Configuring the Ethernet Interface Configuring the Physical PortsConfiguring the STM-1/OC-3c Interface 10E-5,10E-6,10E-7,10E-8,10E-9 10E-3,10E-4,10E-5J1 Path Trace Uplink Port Signal Loss Line Excessive Error DefectLine Signal Degraded Error Uplink Port Loss of SignalConfiguring the Internal Bridge Configuring Fast Ethernet BridgeTo configure the Fast Ethernet bridge Mbps, 8 Mbps, No LimitConfiguring the Bridge Ports Configuring Ethernet Management and Data Bridge PortsTo access the Bridge Port menu To configure the Ethernet management and data bridge portsConfiguring the POS Bridge Port To configure the POS portDisplaying the System Status Displaying the RIC-155 StatusTo display the system information Displaying the Ethernet Port Status Displaying the Port StatusTo display the Ethernet port status Displaying the STM-1/OC-3c Port Status DATA/MNG Port Status ParametersTo display the STM-1/OC-3c port status Parameters ValuesChanging the Password To change the current passwordAdditional Tasks STM-1/OC-3c Port Status Parameters21. User Access Menu Displaying the RIC-155 InventoryInstalling a New Software Release via Tftp Installing Software ReleasesTo install a new software release via Tftp Installing a New Software Release via Xmodem To install a new software release via XmodemTransferring Configuration Files To upload a configuration fileTo download a configuration file Displaying the Software VersionResetting RIC-155 Switching Software VersionsTo switch software versions Resetting RIC-155 to Factory Defaults Resetting RIC-155To reset RIC-155 to the defaults To reset RIC-155Chapter Troubleshooting Diagnostics Monitoring PerformanceDisplaying the Ethernet Statistics To display the Ethernet statisticsDisplaying SDH/SONET Statistics To display the current SDH/SONET statisticsUplink Statistics Screen, Display Description RangeUasl RCV Abort To display SDH/SONET statistics for all intervals 1explains all SDH/SONET statistics parametersDetecting Errors Handling AlarmsPower-Up Self-Test Front Panel LEDsDisplaying System Alarms To display the system alarmsWorking with the Log File To display the event log fileTo configure the alarm severity Configuring Alarm SeverityTo clear the event log Masking Port Alarms To mask RIC-155 alarmsRIC-155 Alarms and Warnings Terminal Message Description SeverityRIC-155 Events Number Terminal Message DescriptionTroubleshooting and Diagnostics Handling Alarms Appendix a Connector Wiring Ethernet ConnectorsAlarm Relay Connector Table A-1. ETH and MNG-ETH Connector PinoutControl Connector Table A-2. Alarm Connector PinoutTable A-3. Control Connector Pinout Pin Alarm Relay FunctionAppendix B Traffic Separation Port-Based Traffic SeparationNone MNG onlyAll Port-Based/VLAN-Based Traffic SeparationLocal Mng Only Default Tagging Table B-1. Default Tagging ModesTagging Modes of the Bridge Ports Uplink and Host PortsForwarding Mode Port Filter Management Access Mode None MNG Only All Local MNG OnlyInternal Operation Modes of the Bridge Ports NoneMNG Only AllManaging RIC-155 via MNG Port Configuring for a Typical ApplicationLocal MNG Only Managing RIC-155 via Data Port Figure B-9. Managing RIC-155 via MNG PortFigure B-10. Managing RIC-155 via Data Port Index RADview-Lite,3-5 STM-1/OC-3c interface, 1-2,1-6Customer Response Form Excellent Good Fair Poor Very PoorPage Error Report Page Page International Headquarters