RAD Data comm Configuration Alternatives, Managing RIC-155 via Terminal Port, Uplink, Bridge

Page 30

Chapter 3 Operation

RIC-155Installation and Operation Manual

 

 

 

 

 

 

 

 

 

Parameter

Default Value

 

 

 

 

 

Flow control

Enable

 

 

 

 

 

Ethernet mode

Full duplex

 

 

 

 

 

LAN speed

100 Mbps

 

 

 

 

 

Uplink

 

 

 

 

 

 

 

Frame type

SONET

 

 

 

 

 

BER threshold

Disable

 

 

 

 

 

EED threshold

10E-3

 

 

SD threshold

10E-6

 

 

J1 Tx path trace enable

Disable

 

 

 

 

 

J1 path trace

 

 

 

 

 

 

 

Physical Failure Forwarding

Disable

 

 

 

 

 

Bridge

 

 

 

 

 

 

 

Aging Time

304

 

 

 

 

 

 

Forwarding Mode

Filter

 

 

 

 

 

Statistics Counted

OK only

 

 

 

 

 

Multicast & Broadcast Rate

No Limit

 

Limit

 

 

 

 

 

 

 

DATA Port PVID

2

 

 

 

 

 

 

DATA Port PVID Priority

0

 

 

 

 

 

 

DATA Port Tag Stripping

No

 

 

 

 

 

MNG Port PVID

1

 

 

 

 

 

 

MNG Port PVID Priority

0

 

 

 

 

 

 

MNG Port Tag Stripping

No

 

 

 

 

 

POS Port Egress

Unmodified

 

 

 

 

3.4Configuration Alternatives

Managing RIC-155 via Terminal Port

RIC-155 includes a V.24/RS-232 asynchronous DTE port, designated CONTROL and terminated in a 9-pin D-type female connector. The control port continuously monitors the incoming data stream and immediately responds to any input string received through this port. The port requires a cross-cable for the ASCII terminal connection.

The RIC-155 control port can be configured to communicate at the following rates: 9.6, 19.2, 38.4, 57.6 or 115.2 kbps. When running a terminal control

3-4

Configuration Alternatives

Image 30
Contents RIC-155 Page RIC-155 Limited Warranty General Safety Instructions Please observe the following precautionsGeneral Safety Practices Connection of AC MainsConnection of DC Mains Ports Safety Status Connection of Data and Telecommunications CablesElectromagnetic Compatibility EMC Canadian Emission Requirements ConventionsProduct Name SafetyManufacturers Name Manufacturers Address Supplementary InformationInstalling RIC-155 Configuring RIC-155Quick Start Guide Configuring RIC-155 To configure RIC-155Contents Troubleshooting and Diagnostics Appendix A. Connector Wiring Appendix B. Traffic SeparationVersions Chapter IntroductionOverview ApplicationSTM-1/OC-3c Interface Features10/100BaseT Interface Fiber Optic Interface OptionsInternal Bridge Alarm RelayManagement Status ReportingPhysical Description RIC-155 3D ViewRIC-155 Block Diagram Functional DescriptionTechnical Specifications Alarm Types Major and minor Connector DB-9, female Temperature 50C / 32-122F Humidity Up to 90%, non-condensingIntroduction Chapter Installation and Setup IntroductionSite Requirements and Prerequisites Package Contents Connecting the Interface CablesConnecting the Power Cable Connecting AC PowerConnecting DC Power Connecting the Power Cable Turning On RIC-155 Controls and IndicatorsChapter Operation To turn on RIC-155RIC-155 LEDs RIC-155 Normal Indicator StatusIndicator Status Name Function LocationDefault Settings RIC-155 Default SettingsManaging RIC-155 via Terminal Port Configuration AlternativesParameter Default Value UplinkStarting Terminal Session for a First Time Managing RIC-155 via Ethernet PortsPreparing the Terminal To prepare RIC-155 for network managementTo start a ConfiguRAD session Navigating the Management Menus Loging onTo enter the user name and password Menu MapCorrecting Entries To choose an option ConfiguRAD sessionChoosing Options To choose an option terminal sessionTurning Off RIC-155 Navigating TablesLogging Out Operation Turning Off RIC-155 To access the Configuration menu Chapter ConfigurationConfiguring RIC-155 for Management To access the Management menuEntering Device Information To enter device informationConfiguring the Host Parameters To define the IP parametersConfiguring the Network Managers To configure the network managersControlling the Management Access To define the management access methodConfiguring the RIC-155 for Operation To enable or disable management portsConfiguring the Clock Source Configuring Control Port ParametersEnabling and Disabling Pop-up Alarms Configuring the Security TimeoutChanging the Control Port Data Rate Configuring the Physical Ports Configuring the Ethernet InterfaceConfiguring the STM-1/OC-3c Interface 10E-3,10E-4,10E-5 10E-5,10E-6,10E-7,10E-8,10E-9J1 Path Trace Line Signal Degraded Error Uplink Port Signal LossLine Excessive Error Defect Uplink Port Loss of SignalTo configure the Fast Ethernet bridge Configuring the Internal BridgeConfiguring Fast Ethernet Bridge Mbps, 8 Mbps, No LimitTo access the Bridge Port menu Configuring the Bridge PortsConfiguring Ethernet Management and Data Bridge Ports To configure the Ethernet management and data bridge portsConfiguring the POS Bridge Port To configure the POS portDisplaying the RIC-155 Status Displaying the System StatusTo display the system information Displaying the Port Status Displaying the Ethernet Port StatusTo display the Ethernet port status To display the STM-1/OC-3c port status Displaying the STM-1/OC-3c Port StatusDATA/MNG Port Status Parameters Parameters ValuesAdditional Tasks Changing the PasswordTo change the current password STM-1/OC-3c Port Status Parameters21. User Access Menu Displaying the RIC-155 InventoryInstalling Software Releases Installing a New Software Release via TftpTo install a new software release via Tftp Installing a New Software Release via Xmodem To install a new software release via XmodemTo download a configuration file Transferring Configuration FilesTo upload a configuration file Displaying the Software VersionSwitching Software Versions Resetting RIC-155To switch software versions To reset RIC-155 to the defaults Resetting RIC-155 to Factory DefaultsResetting RIC-155 To reset RIC-155Displaying the Ethernet Statistics Chapter Troubleshooting DiagnosticsMonitoring Performance To display the Ethernet statisticsDisplaying SDH/SONET Statistics To display the current SDH/SONET statisticsUplink Statistics Screen, Display Description RangeUasl RCV Abort To display SDH/SONET statistics for all intervals 1explains all SDH/SONET statistics parametersPower-Up Self-Test Detecting ErrorsHandling Alarms Front Panel LEDsWorking with the Log File Displaying System AlarmsTo display the system alarms To display the event log fileConfiguring Alarm Severity To configure the alarm severityTo clear the event log RIC-155 Alarms and Warnings Masking Port AlarmsTo mask RIC-155 alarms Terminal Message Description SeverityRIC-155 Events Number Terminal Message DescriptionTroubleshooting and Diagnostics Handling Alarms Alarm Relay Connector Appendix a Connector WiringEthernet Connectors Table A-1. ETH and MNG-ETH Connector PinoutTable A-3. Control Connector Pinout Control ConnectorTable A-2. Alarm Connector Pinout Pin Alarm Relay FunctionNone Appendix B Traffic SeparationPort-Based Traffic Separation MNG onlyPort-Based/VLAN-Based Traffic Separation AllLocal Mng Only Tagging Modes of the Bridge Ports Default TaggingTable B-1. Default Tagging Modes Uplink and Host PortsInternal Operation Modes of the Bridge Ports Forwarding Mode Port FilterManagement Access Mode None MNG Only All Local MNG Only NoneMNG Only AllConfiguring for a Typical Application Managing RIC-155 via MNG PortLocal MNG Only Managing RIC-155 via Data Port Figure B-9. Managing RIC-155 via MNG PortFigure B-10. Managing RIC-155 via Data Port Index RADview-Lite,3-5 STM-1/OC-3c interface, 1-2,1-6Customer Response Form Excellent Good Fair Poor Very PoorPage Error Report Page Page International Headquarters